Integration of linear alternators in thermoacoustic heat Engines

A thermoacoustic power converter consists of a thermoacoustic heat engine driving a linear alternator connected to a matched electric load. Accordingly, linear alternators are essential parts of thermoacoustic power converters. However, integration of a linear alternator in a thermoacoustic power co...

Full description

Saved in:
Bibliographic Details
Main Author: Abdelmwgoud, Moamen Bellah
Format: Thesis
Published: AUC Knowledge Fountain 2015
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613408029835264
access_status_str Open Access
author Abdelmwgoud, Moamen Bellah
author_browse Abdelmwgoud, Moamen Bellah
author_facet Abdelmwgoud, Moamen Bellah
author_sort Abdelmwgoud, Moamen Bellah
collection Thesis
dc_rights_str_mv The author retains all rights with regard to copyright. The author certifies that written permission from the owner(s) of third-party copyrighted matter included in the thesis, dissertation, paper, or record of study has been obtained. The author further certifies that IRB approval has been obtained for this thesis, or that IRB approval is not necessary for this thesis. Insofar as this thesis, dissertation, paper, or record of study is an educational record as defined in the Family Educational Rights and Privacy Act (FERPA) (20 USC 1232g), the author has granted consent to disclosure of it to anyone who requests a copy.
description A thermoacoustic power converter consists of a thermoacoustic heat engine driving a linear alternator connected to a matched electric load. Accordingly, linear alternators are essential parts of thermoacoustic power converters. However, integration of a linear alternator in a thermoacoustic power converter is complicated since it requires acoustic matching with the thermoacoustic engine as well as electrical matching with the electric load connected to it and fast protection against piston over-stroking. In order to simplify the integration process, an experimental setup designed and built, in which the acoustic power generated by a thermoacoustic engine simulated by an acoustic driver. This setup provides a platform to test and evaluate the performance of a linear alternator in a controlled environment before integrated into thermoacoustic heat engines that allows identification and resolution of potential problems only related to linear alternators. A control circuit designed and built to protect the alternator’s piston against over-stroking. A non-linear electric load connected to the alternator to provide a stable operating point of the complete system. In this setup, instrumentation is used to monitor the main variables (input and output current, input and output volt, dynamic gas pressure at exit of acoustic driver and inlet of linear alternator, dynamic gas pressure in the enclosure volume of the acoustic driver and linear alternator, acoustic driver stroke, linear alternator stroke, air and coil temperatures). The setup allows use of different resonators to simulate the effects of different front volumes on the performance of linear alternators and allows alterations in the enclosure volumes housing the acoustic driver and/or alternator to control their resonance frequencies. Results show the performance of a given linear alternator under different operating frequencies, mean gas pressure, gas mixtures, input voltage, electrical resistance and zener break-down voltage.
format Thesis
id oai:fount.aucegypt.edu:etds-1151
institution American University in Cairo (Egypt)
last_indexed 2026-06-10T12:35:39.635Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from AUC Knowledge Fountain — bepress
publishDate 2015
publishDateRange 2015
publishDateSort 2015
publisher AUC Knowledge Fountain
publisherStr AUC Knowledge Fountain
record_format dspace
source_str AUC Knowledge Fountain — bepress
spelling oai:fount.aucegypt.edu:etds-1151 Integration of linear alternators in thermoacoustic heat Engines Abdelmwgoud, Moamen Bellah A thermoacoustic power converter consists of a thermoacoustic heat engine driving a linear alternator connected to a matched electric load. Accordingly, linear alternators are essential parts of thermoacoustic power converters. However, integration of a linear alternator in a thermoacoustic power converter is complicated since it requires acoustic matching with the thermoacoustic engine as well as electrical matching with the electric load connected to it and fast protection against piston over-stroking. In order to simplify the integration process, an experimental setup designed and built, in which the acoustic power generated by a thermoacoustic engine simulated by an acoustic driver. This setup provides a platform to test and evaluate the performance of a linear alternator in a controlled environment before integrated into thermoacoustic heat engines that allows identification and resolution of potential problems only related to linear alternators. A control circuit designed and built to protect the alternator’s piston against over-stroking. A non-linear electric load connected to the alternator to provide a stable operating point of the complete system. In this setup, instrumentation is used to monitor the main variables (input and output current, input and output volt, dynamic gas pressure at exit of acoustic driver and inlet of linear alternator, dynamic gas pressure in the enclosure volume of the acoustic driver and linear alternator, acoustic driver stroke, linear alternator stroke, air and coil temperatures). The setup allows use of different resonators to simulate the effects of different front volumes on the performance of linear alternators and allows alterations in the enclosure volumes housing the acoustic driver and/or alternator to control their resonance frequencies. Results show the performance of a given linear alternator under different operating frequencies, mean gas pressure, gas mixtures, input voltage, electrical resistance and zener break-down voltage. 2015-06-01T07:00:00Z thesis application/pdf https://fount.aucegypt.edu/etds/152 https://fount.aucegypt.edu/context/etds/article/1151/viewcontent/Integration_20of_20Linear_20Alternators_20in_20Thermoacoustic_20Heat_20Engines.pdf The author retains all rights with regard to copyright. The author certifies that written permission from the owner(s) of third-party copyrighted matter included in the thesis, dissertation, paper, or record of study has been obtained. The author further certifies that IRB approval has been obtained for this thesis, or that IRB approval is not necessary for this thesis. Insofar as this thesis, dissertation, paper, or record of study is an educational record as defined in the Family Educational Rights and Privacy Act (FERPA) (20 USC 1232g), the author has granted consent to disclosure of it to anyone who requests a copy. Theses and Dissertations AUC Knowledge Fountain Linear Alternators Thermoacoustic Heat Engines
spellingShingle Linear Alternators
Thermoacoustic Heat Engines
Abdelmwgoud, Moamen Bellah
Integration of linear alternators in thermoacoustic heat Engines
title Integration of linear alternators in thermoacoustic heat Engines
title_full Integration of linear alternators in thermoacoustic heat Engines
title_fullStr Integration of linear alternators in thermoacoustic heat Engines
title_full_unstemmed Integration of linear alternators in thermoacoustic heat Engines
title_short Integration of linear alternators in thermoacoustic heat Engines
title_sort integration of linear alternators in thermoacoustic heat engines
topic Linear Alternators
Thermoacoustic Heat Engines
url https://fount.aucegypt.edu/etds/152
https://fount.aucegypt.edu/context/etds/article/1151/viewcontent/Integration_20of_20Linear_20Alternators_20in_20Thermoacoustic_20Heat_20Engines.pdf
work_keys_str_mv AT abdelmwgoudmoamenbellah integrationoflinearalternatorsinthermoacousticheatengines