Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Greywater treatment using electrocoagulation for possible reuse

The non-stop growing demand on fresh water to meet the booming population and its corresponding activities, such as domestic, industrial, and agricultural developments, necessitates finding means to preserve our natural water resources and find alternative sources than can still meet our different n...

Full description

Saved in:
Bibliographic Details
Main Author: Youssef, Sarah Omar
Format: Thesis
Published: AUC Knowledge Fountain 2020
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613420349554688
access_status_str Open Access
author Youssef, Sarah Omar
author_browse Youssef, Sarah Omar
author_facet Youssef, Sarah Omar
author_sort Youssef, Sarah Omar
collection Thesis
dc_rights_str_mv The author retains all rights with regard to copyright. The author certifies that written permission from the owner(s) of third-party copyrighted matter included in the thesis, dissertation, paper, or record of study has been obtained. The author further certifies that IRB approval has been obtained for this thesis, or that IRB approval is not necessary for this thesis. Insofar as this thesis, dissertation, paper, or record of study is an educational record as defined in the Family Educational Rights and Privacy Act (FERPA) (20 USC 1232g), the author has granted consent to disclosure of it to anyone who requests a copy. The author has granted the American University in Cairo or its agents a non-exclusive license to archive this thesis, dissertation, paper, or record of study, and to make it accessible, in whole or in part, in all forms of media, now or hereafter known.
description The non-stop growing demand on fresh water to meet the booming population and its corresponding activities, such as domestic, industrial, and agricultural developments, necessitates finding means to preserve our natural water resources and find alternative sources than can still meet our different needs. Greywater is one of the most potential alternatives that can be reused in some water consuming activities such as toilet flushing, gardening, landscape irrigation, and for agricultural purposes instead of wasting the higher water quality of potable water from being used in non-potable water activities. The present research was undertaken to investigate the potential of electrocoagulation technique for the treatment of greywater. The investigation work has been divided into two main phases. Phase I included studying the effect of the electrocoagulation operating parameters, such as the electrode surface area to water volume ratio, current density and electrolysis time, on the removal of COD and turbidity from synthetic greywater using I-optimal design of response surface methodology by Design expert 12 software. The experimental results showed model adequacy and significance. The experimental work was done on laboratory scale and a batch mode of operation. Three optimum conditions were chosen based on COD removal efficiencies of < 50%, 50%, and >50%, while maintaining residual turbidity value of no greater than 5 NTU and minimizing power consumption. Accordingly, three optimum set of conditions were obtained: set no.1 (CD = 31.06 A/m2, S/V =12.6 m -1, and T = 40 min), set no. 2 (CD = 62.13 A/m2, S/V =12.6 m-1, and T = 35 min) and set no.3 (CD = 73 A/m2, S/V =16.083 m-1, T=45 min). These optimum conditions achieved COD removal percent of 42.5, 51.08, and 56.06, respectively. Turbidity removal was 84.84%, 88.46% and 89.4%, while the specific power consumed was 3.9, 10.06, and 22.95 kWh/m3 for the three sets respectively. In phase II, the obtained optimum conditions of phase I were examined on the removal of BOD5,COD, Turbidity, TSS and FC from the real greywater and compared with different codes and standards. Compared to phase I, higher removal efficiencies of COD and turbidity were obtained in the three optimum sets. 80.6, 82.25, and 84.02 % COD removal, and 95.5, 95.5, 98.08 % turbidity removal with power consumption of 5.49, 8.23 and 21.6 kWh/m3 in the three experimental setups, respectively. Furthermore, the removal of other pollutant indicators, i.e.BOD5, FC, and TSS, were also studied. BOD5 removal efficiencies were 82.96%, 86.75%, and 87.88% in three experiments respectively. Also, FC were reduced by 99.65%, 99.64%, and 99.96%. In addition, TSS was removed by 83.19%, 92.98%, and 94.73% in the three experiments respectively. The treatment cost for the three experimental setups was estimated to be 9.46, 15.05, 33.49 EGP/m3 and 1.13, 1.8, and 4.0 EGP/capita/day, including power and electrode consumption. Sludge characterization of the first experimental setup using EDS and SEM showed that O, Al, C were three prevailing elements with a percentage of 51.62%, 29.69%,and 14.74% respectively. It can be concluded that electrocoagulation is a promising technique that could be used as a standalone system for the treatment of real greywater. However, further analysis on the diseases causing bacteria content in the water might be required to be able to meet the concerned codes and standards for reuse in different applications.
format Thesis
id oai:fount.aucegypt.edu:etds-2745
institution American University in Cairo (Egypt)
last_indexed 2026-06-10T12:35:51.500Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from AUC Knowledge Fountain — bepress
publishDate 2020
publishDateRange 2020
publishDateSort 2020
publisher AUC Knowledge Fountain
publisherStr AUC Knowledge Fountain
record_format dspace
source_str AUC Knowledge Fountain — bepress
spelling oai:fount.aucegypt.edu:etds-2745 Greywater treatment using electrocoagulation for possible reuse Youssef, Sarah Omar The non-stop growing demand on fresh water to meet the booming population and its corresponding activities, such as domestic, industrial, and agricultural developments, necessitates finding means to preserve our natural water resources and find alternative sources than can still meet our different needs. Greywater is one of the most potential alternatives that can be reused in some water consuming activities such as toilet flushing, gardening, landscape irrigation, and for agricultural purposes instead of wasting the higher water quality of potable water from being used in non-potable water activities. The present research was undertaken to investigate the potential of electrocoagulation technique for the treatment of greywater. The investigation work has been divided into two main phases. Phase I included studying the effect of the electrocoagulation operating parameters, such as the electrode surface area to water volume ratio, current density and electrolysis time, on the removal of COD and turbidity from synthetic greywater using I-optimal design of response surface methodology by Design expert 12 software. The experimental results showed model adequacy and significance. The experimental work was done on laboratory scale and a batch mode of operation. Three optimum conditions were chosen based on COD removal efficiencies of < 50%, 50%, and >50%, while maintaining residual turbidity value of no greater than 5 NTU and minimizing power consumption. Accordingly, three optimum set of conditions were obtained: set no.1 (CD = 31.06 A/m2, S/V =12.6 m -1, and T = 40 min), set no. 2 (CD = 62.13 A/m2, S/V =12.6 m-1, and T = 35 min) and set no.3 (CD = 73 A/m2, S/V =16.083 m-1, T=45 min). These optimum conditions achieved COD removal percent of 42.5, 51.08, and 56.06, respectively. Turbidity removal was 84.84%, 88.46% and 89.4%, while the specific power consumed was 3.9, 10.06, and 22.95 kWh/m3 for the three sets respectively. In phase II, the obtained optimum conditions of phase I were examined on the removal of BOD5,COD, Turbidity, TSS and FC from the real greywater and compared with different codes and standards. Compared to phase I, higher removal efficiencies of COD and turbidity were obtained in the three optimum sets. 80.6, 82.25, and 84.02 % COD removal, and 95.5, 95.5, 98.08 % turbidity removal with power consumption of 5.49, 8.23 and 21.6 kWh/m3 in the three experimental setups, respectively. Furthermore, the removal of other pollutant indicators, i.e.BOD5, FC, and TSS, were also studied. BOD5 removal efficiencies were 82.96%, 86.75%, and 87.88% in three experiments respectively. Also, FC were reduced by 99.65%, 99.64%, and 99.96%. In addition, TSS was removed by 83.19%, 92.98%, and 94.73% in the three experiments respectively. The treatment cost for the three experimental setups was estimated to be 9.46, 15.05, 33.49 EGP/m3 and 1.13, 1.8, and 4.0 EGP/capita/day, including power and electrode consumption. Sludge characterization of the first experimental setup using EDS and SEM showed that O, Al, C were three prevailing elements with a percentage of 51.62%, 29.69%,and 14.74% respectively. It can be concluded that electrocoagulation is a promising technique that could be used as a standalone system for the treatment of real greywater. However, further analysis on the diseases causing bacteria content in the water might be required to be able to meet the concerned codes and standards for reuse in different applications. 2020-01-15T08:00:00Z thesis application/pdf https://fount.aucegypt.edu/etds/1705 https://fount.aucegypt.edu/context/etds/article/2745/viewcontent/MSc._20Thesis_20__20Sarah_20Youssef__20Greywater_20treatment_20using_20electrocoagulation_20for_20possible_20reuse.pdf The author retains all rights with regard to copyright. The author certifies that written permission from the owner(s) of third-party copyrighted matter included in the thesis, dissertation, paper, or record of study has been obtained. The author further certifies that IRB approval has been obtained for this thesis, or that IRB approval is not necessary for this thesis. Insofar as this thesis, dissertation, paper, or record of study is an educational record as defined in the Family Educational Rights and Privacy Act (FERPA) (20 USC 1232g), the author has granted consent to disclosure of it to anyone who requests a copy. The author has granted the American University in Cairo or its agents a non-exclusive license to archive this thesis, dissertation, paper, or record of study, and to make it accessible, in whole or in part, in all forms of media, now or hereafter known. Theses and Dissertations AUC Knowledge Fountain Electrocoagulation Greywater treatment
spellingShingle Electrocoagulation
Greywater treatment
Youssef, Sarah Omar
Greywater treatment using electrocoagulation for possible reuse
title Greywater treatment using electrocoagulation for possible reuse
title_full Greywater treatment using electrocoagulation for possible reuse
title_fullStr Greywater treatment using electrocoagulation for possible reuse
title_full_unstemmed Greywater treatment using electrocoagulation for possible reuse
title_short Greywater treatment using electrocoagulation for possible reuse
title_sort greywater treatment using electrocoagulation for possible reuse
topic Electrocoagulation
Greywater treatment
url https://fount.aucegypt.edu/etds/1705
https://fount.aucegypt.edu/context/etds/article/2745/viewcontent/MSc._20Thesis_20__20Sarah_20Youssef__20Greywater_20treatment_20using_20electrocoagulation_20for_20possible_20reuse.pdf
work_keys_str_mv AT youssefsarahomar greywatertreatmentusingelectrocoagulationforpossiblereuse