Continuous gauging of electric traction contact wire

Includes bibliographical references.

Saved in:
Bibliographic Details
Main Author: Timm, Anthony Rex
Other Authors: Besseling, Johann L N
Format: Thesis
Language:English
Published: Department of Electrical Engineering 2015
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613307425259520
access_status_str Open Access
author Timm, Anthony Rex
author2 Besseling, Johann L N
author_browse Besseling, Johann L N
Timm, Anthony Rex
author_facet Besseling, Johann L N
Timm, Anthony Rex
author_sort Timm, Anthony Rex
collection Thesis
description Includes bibliographical references.
format Thesis
id oai:open.uct.ac.za:11427/12432
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:34:03.682Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2015
publishDateRange 2015
publishDateSort 2015
publisher Department of Electrical Engineering
publisherStr Department of Electrical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/12432 Continuous gauging of electric traction contact wire Timm, Anthony Rex Besseling, Johann L N Van Nierop, J H Electrical Engineering Includes bibliographical references. In this system the electric traction overhead contact wire wear is continuously measured. A GaAs LED and lens combination produces a collimated beam of light along the pantograph pan. The beam, through which the contact wire slides, is monitored by a vertical array of phototransistors spaced at equal intervals. The number of phototransistors in shadow at any instant is proportional to the contact wire thickness. A fibre-optic data link conveys the encoded information from the pan at high tension to the locomotive at ground potential. 2015-02-11T14:08:21Z 2015-02-11T14:08:21Z 1975 Master Thesis Masters MSc http://hdl.handle.net/11427/12432 eng application/pdf Department of Electrical Engineering Faculty of Engineering and the Built Environment University of Cape Town
spellingShingle Electrical Engineering
Timm, Anthony Rex
Continuous gauging of electric traction contact wire
thesis_degree_str Master's
title Continuous gauging of electric traction contact wire
title_full Continuous gauging of electric traction contact wire
title_fullStr Continuous gauging of electric traction contact wire
title_full_unstemmed Continuous gauging of electric traction contact wire
title_short Continuous gauging of electric traction contact wire
title_sort continuous gauging of electric traction contact wire
topic Electrical Engineering
url http://hdl.handle.net/11427/12432
work_keys_str_mv AT timmanthonyrex continuousgaugingofelectrictractioncontactwire