Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Development and testing of experimental equipment to measure pore pressure and dynamic pressure at points outside a pipe leak

Includes bibliographical references.

Saved in:
Bibliographic Details
Main Author: Bailey, Nicholas David
Other Authors: Van Zyl, J E
Format: Thesis
Language:English
Published: Department of Civil Engineering 2015
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613325786873856
access_status_str Open Access
author Bailey, Nicholas David
author2 Van Zyl, J E
author_browse Bailey, Nicholas David
Van Zyl, J E
author_facet Van Zyl, J E
Bailey, Nicholas David
author_sort Bailey, Nicholas David
collection Thesis
description Includes bibliographical references.
format Thesis
id oai:open.uct.ac.za:11427/13655
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:34:20.437Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2015
publishDateRange 2015
publishDateSort 2015
publisher Department of Civil Engineering
publisherStr Department of Civil Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/13655 Development and testing of experimental equipment to measure pore pressure and dynamic pressure at points outside a pipe leak Bailey, Nicholas David Van Zyl, J E Civil Engineering Includes bibliographical references. Leaks in water distribution mains are a major issue throughout the world. The amount of water lost through these leaks is unacceptable for a resource, which is becoming ever scarcer. Little is known about the fundamentals, which exist outside leaking water distribution mains. The se fundamentals are the interaction between the leaking water and the soil surrounding the distribution main. This interaction is known as the leak - soil interaction. Research has found that a phenomenon called internal fluidisation typically occurs in the soils outside of leaks in distribution mains. Internal fluidisation is a complex interaction between the leak and the surrounding soil, whereby the soil losses its intermolecular bonding and becomes displaced by the water jet generated by the leak. It is believed that this complex phenomenon causes large energy losses. Subsequently, many water leaks are not able to propagate to the ground surface where they will be visible. This leads to many such leaks being undetected below the ground surface. The objective of this study was to develop an experimental setup, which simulated the internal fluidisation phenomenon. The setup consisted primarily of an orifice, simulating a leak in a distribution pipe; surrounded by ballotini (glass beads), as the soil medium surrounding the pipe; and the measurement instruments, which were Pitot tubes. When using the experimental setup, pore pressures and dynamic pressures around the leak and therefore within the ballotini bed were measured using two Pitot tubes. The accuracy and repeatability of these measurements were also of importance and were investigated. The accuracy of the measurements were dependant on the precision of the Pitot tubes in taking measurements. They were found to have an error of up to 4.1 %, although the experiment to test for the accuracy was not fool proof. The repeatability of the measurements was found to have a 3.8 % average difference between the previous and repeated measurements. The measuring of the pore pressures and dynamic pressures resulted in the following findings, which were the most important in the study: There were large vertical velocities found in the fluidized zone, where outside of this zone they were significantly smaller. The largest pore pressure was found to occur near the top of the fluidised zone. The pore pressures in the bed from a certain distance away from the orifice had a linear distribution, illustrating that Darcy water flow was present. High energy existed in the fluidised zone where it was greatest nearest the orifice and decreased to the top of the fluidised zone. In the ballotini bed outside of the fluidised zone the energy was found to be considerably smaller and decreased further away from the orifice. 2015-08-10T06:14:41Z 2015-08-10T06:14:41Z 2015 Master Thesis Masters MSc (Eng) http://hdl.handle.net/11427/13655 eng application/pdf Department of Civil Engineering Faculty of Engineering and the Built Environment University of Cape Town
spellingShingle Civil Engineering
Bailey, Nicholas David
Development and testing of experimental equipment to measure pore pressure and dynamic pressure at points outside a pipe leak
thesis_degree_str Master's
title Development and testing of experimental equipment to measure pore pressure and dynamic pressure at points outside a pipe leak
title_full Development and testing of experimental equipment to measure pore pressure and dynamic pressure at points outside a pipe leak
title_fullStr Development and testing of experimental equipment to measure pore pressure and dynamic pressure at points outside a pipe leak
title_full_unstemmed Development and testing of experimental equipment to measure pore pressure and dynamic pressure at points outside a pipe leak
title_short Development and testing of experimental equipment to measure pore pressure and dynamic pressure at points outside a pipe leak
title_sort development and testing of experimental equipment to measure pore pressure and dynamic pressure at points outside a pipe leak
topic Civil Engineering
url http://hdl.handle.net/11427/13655
work_keys_str_mv AT baileynicholasdavid developmentandtestingofexperimentalequipmenttomeasureporepressureanddynamicpressureatpointsoutsideapipeleak