Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) as a screening tool for raised intracranial pressure in an acute care setting in children

Background: Acute care management of pediatric traumatic brain injury (TBI) can be challenging. Early and reliable diagnosis of intracranial pressure (ICP) in children following TBI is vital in optimizing outcome. Clinical findings of raised ICP can be non-specific and are often missed in minor inj...

Full description

Saved in:
Bibliographic Details
Main Author: Padayachy, Vaishali
Other Authors: Van As, Sebastian
Format: Thesis
Language:English
Published: Department of Surgery 2016
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613332175847424
access_status_str Open Access
author Padayachy, Vaishali
author2 Van As, Sebastian
author_browse Padayachy, Vaishali
Van As, Sebastian
author_facet Van As, Sebastian
Padayachy, Vaishali
author_sort Padayachy, Vaishali
collection Thesis
description Background: Acute care management of pediatric traumatic brain injury (TBI) can be challenging. Early and reliable diagnosis of intracranial pressure (ICP) in children following TBI is vital in optimizing outcome. Clinical findings of raised ICP can be non-specific and are often missed in minor injuries, leading to severe consequences. The use of a simple, quick, accurate, non-invasive technique to assess ICP can be invaluable in this setting. Based on the hypothesis that acutely raised ICP will result in an enlargement of the optic nerve sheath diameter (ONSD), this study aimed to demonstrate the efficacy of transorbital measurement of the ONSD as a routine screening tool in pediatric TBI. Methodology: This was a prospective observational analysis of a pediatric cohort of patients with head injury, treated in the trauma unit. All children included in the study were clinically assessed, and had indications for cranial computer tomography (CT) scan. All optic nerve sheath imaging was conducted by a single investigator, experienced in the use of ultrasound for emergency care. ONSD measurements were conducted using a high frequency, linear array probe. Patients were sedated and ONSD measurement was performed prior to or immediately after CT imaging. A total of 12 images were obtained in each patient, 3 axial and 3 sagittal images in each eye and the mean ONSD was calculated. ONSD measurements were analyzed in relation to clinical severity, CT findings of raised ICP and outcome of the patient.
format Thesis
id oai:open.uct.ac.za:11427/20431
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:34:27.383Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2016
publishDateRange 2016
publishDateSort 2016
publisher Department of Surgery
publisherStr Department of Surgery
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/20431 Transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) as a screening tool for raised intracranial pressure in an acute care setting in children Padayachy, Vaishali Van As, Sebastian Surgery Background: Acute care management of pediatric traumatic brain injury (TBI) can be challenging. Early and reliable diagnosis of intracranial pressure (ICP) in children following TBI is vital in optimizing outcome. Clinical findings of raised ICP can be non-specific and are often missed in minor injuries, leading to severe consequences. The use of a simple, quick, accurate, non-invasive technique to assess ICP can be invaluable in this setting. Based on the hypothesis that acutely raised ICP will result in an enlargement of the optic nerve sheath diameter (ONSD), this study aimed to demonstrate the efficacy of transorbital measurement of the ONSD as a routine screening tool in pediatric TBI. Methodology: This was a prospective observational analysis of a pediatric cohort of patients with head injury, treated in the trauma unit. All children included in the study were clinically assessed, and had indications for cranial computer tomography (CT) scan. All optic nerve sheath imaging was conducted by a single investigator, experienced in the use of ultrasound for emergency care. ONSD measurements were conducted using a high frequency, linear array probe. Patients were sedated and ONSD measurement was performed prior to or immediately after CT imaging. A total of 12 images were obtained in each patient, 3 axial and 3 sagittal images in each eye and the mean ONSD was calculated. ONSD measurements were analyzed in relation to clinical severity, CT findings of raised ICP and outcome of the patient. 2016-07-18T12:52:59Z 2016-07-18T12:52:59Z 2016 Master Thesis Masters MPhil http://hdl.handle.net/11427/20431 eng application/pdf Department of Surgery Faculty of Health Sciences University of Cape Town
spellingShingle Surgery
Padayachy, Vaishali
Transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) as a screening tool for raised intracranial pressure in an acute care setting in children
thesis_degree_str Master's
title Transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) as a screening tool for raised intracranial pressure in an acute care setting in children
title_full Transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) as a screening tool for raised intracranial pressure in an acute care setting in children
title_fullStr Transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) as a screening tool for raised intracranial pressure in an acute care setting in children
title_full_unstemmed Transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) as a screening tool for raised intracranial pressure in an acute care setting in children
title_short Transorbital ultrasound measurement of the optic nerve sheath diameter (ONSD) as a screening tool for raised intracranial pressure in an acute care setting in children
title_sort transorbital ultrasound measurement of the optic nerve sheath diameter onsd as a screening tool for raised intracranial pressure in an acute care setting in children
topic Surgery
url http://hdl.handle.net/11427/20431
work_keys_str_mv AT padayachyvaishali transorbitalultrasoundmeasurementoftheopticnervesheathdiameteronsdasascreeningtoolforraisedintracranialpressureinanacutecaresettinginchildren