Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Investigation into methods for the calculation and measurement of pulverised coal boiler flue gas furnace exit temperature

The boiler flue gas furnace exit temperature (FET) is a key operating parameter of coal fired steam boilers. From the design perspective, the FET is vital for materials selection and sizing of heat transfer surfaces. From an operating perspective, it is a major indicator of the rate of combustion an...

Full description

Saved in:
Bibliographic Details
Main Author: Tootla, Naeem Ebrahim
Other Authors: Jestin, Louis
Format: Thesis
Language:English
Published: Department of Mechanical Engineering 2016
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613142744301568
access_status_str Open Access
author Tootla, Naeem Ebrahim
author2 Jestin, Louis
author_browse Jestin, Louis
Tootla, Naeem Ebrahim
author_facet Jestin, Louis
Tootla, Naeem Ebrahim
author_sort Tootla, Naeem Ebrahim
collection Thesis
description The boiler flue gas furnace exit temperature (FET) is a key operating parameter of coal fired steam boilers. From the design perspective, the FET is vital for materials selection and sizing of heat transfer surfaces. From an operating perspective, it is a major indicator of the rate of combustion and heat transfer that is occurring within the furnace. Downstream of the furnace, the FET has a significant impact on both the performance and reliability of the boiler heat exchangers, which ultimately impacts on both boiler efficiency and availability. Monitoring of the FET can advise operating and engineering corrective actions which will ultimately result in better efficiency, reliability and availability together with the associated economic benefits. Therefore, methods of determining FET are investigated. Two methods are focused on for this study, one indirect and one direct. The indirect method studied is a mass and energy balance method which begins with a global boiler mass and energy balance to calculate the major boiler flow rates of coal, air and flue gas which are difficult to measure online. These parameters are then used as inputs into a furnace or backpass mass and energy balance to calculate the furnace exit temperature. The method is applied to a case study, and is evaluated in terms of the measurement uncertainties which are propagated on the intermediate parameters calculated, as well as on the final calculated FET. The main conclusions are that this indirect method contains various uncertainties, due to parameters which have to be assumed such as (i) the distribution of ingress air (also called tramp air) in the different sections of the boiler and (ii) the estimation of the share of water evaporation heat transfer occurring in the water walls of the furnace part of the boiler. The method is however still useful and can be easily applied to any boiler layout and can be used as a reference tool to verify other measurements. The direct method studied is acoustic pyrometry. The work specifically focuses on the sources of error in determining the temperature from the measurement of the time of flight of sound, the impact of particle concentration on the speed of sound through a gas-particle mixture, and the temperature profile reconstruction from acoustic time of flight measurements. A limited set of physical testing was also carried out using one acoustic generator and receiver to take measurements on a real coal power plant. As part of this physical testing, the detection of time of flight from acoustic signals was explored. Already installed radiation pyrometers were also used as a reference for interpreting the acoustic measurements. The indications are that the acoustic pyrometer provides a more representative temperature measurement than the radiation pyrometers. The uncertainty of the acoustic measurement for the same case study as the indirect method was determined and compared with the calculated result. While many aspects still need to be researched further, this initial study and experimental testing produced very promising results for future application of acoustic pyrometry for better monitoring of the coal combustion processes in power plant boilers.
format Thesis
id oai:open.uct.ac.za:11427/20562
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:31:26.417Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2016
publishDateRange 2016
publishDateSort 2016
publisher Department of Mechanical Engineering
publisherStr Department of Mechanical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/20562 Investigation into methods for the calculation and measurement of pulverised coal boiler flue gas furnace exit temperature Tootla, Naeem Ebrahim Jestin, Louis Mechanical Engineering Boiler furnace exit temperature Mass and energy balances Acoustic pyrometer The boiler flue gas furnace exit temperature (FET) is a key operating parameter of coal fired steam boilers. From the design perspective, the FET is vital for materials selection and sizing of heat transfer surfaces. From an operating perspective, it is a major indicator of the rate of combustion and heat transfer that is occurring within the furnace. Downstream of the furnace, the FET has a significant impact on both the performance and reliability of the boiler heat exchangers, which ultimately impacts on both boiler efficiency and availability. Monitoring of the FET can advise operating and engineering corrective actions which will ultimately result in better efficiency, reliability and availability together with the associated economic benefits. Therefore, methods of determining FET are investigated. Two methods are focused on for this study, one indirect and one direct. The indirect method studied is a mass and energy balance method which begins with a global boiler mass and energy balance to calculate the major boiler flow rates of coal, air and flue gas which are difficult to measure online. These parameters are then used as inputs into a furnace or backpass mass and energy balance to calculate the furnace exit temperature. The method is applied to a case study, and is evaluated in terms of the measurement uncertainties which are propagated on the intermediate parameters calculated, as well as on the final calculated FET. The main conclusions are that this indirect method contains various uncertainties, due to parameters which have to be assumed such as (i) the distribution of ingress air (also called tramp air) in the different sections of the boiler and (ii) the estimation of the share of water evaporation heat transfer occurring in the water walls of the furnace part of the boiler. The method is however still useful and can be easily applied to any boiler layout and can be used as a reference tool to verify other measurements. The direct method studied is acoustic pyrometry. The work specifically focuses on the sources of error in determining the temperature from the measurement of the time of flight of sound, the impact of particle concentration on the speed of sound through a gas-particle mixture, and the temperature profile reconstruction from acoustic time of flight measurements. A limited set of physical testing was also carried out using one acoustic generator and receiver to take measurements on a real coal power plant. As part of this physical testing, the detection of time of flight from acoustic signals was explored. Already installed radiation pyrometers were also used as a reference for interpreting the acoustic measurements. The indications are that the acoustic pyrometer provides a more representative temperature measurement than the radiation pyrometers. The uncertainty of the acoustic measurement for the same case study as the indirect method was determined and compared with the calculated result. While many aspects still need to be researched further, this initial study and experimental testing produced very promising results for future application of acoustic pyrometry for better monitoring of the coal combustion processes in power plant boilers. 2016-07-21T11:04:17Z 2016-07-21T11:04:17Z 2016 Master Thesis Masters MSc (Eng) http://hdl.handle.net/11427/20562 eng application/pdf Department of Mechanical Engineering Faculty of Engineering and the Built Environment University of Cape Town
spellingShingle Mechanical Engineering
Boiler furnace exit temperature
Mass and energy balances
Acoustic pyrometer
Tootla, Naeem Ebrahim
Investigation into methods for the calculation and measurement of pulverised coal boiler flue gas furnace exit temperature
thesis_degree_str Master's
title Investigation into methods for the calculation and measurement of pulverised coal boiler flue gas furnace exit temperature
title_full Investigation into methods for the calculation and measurement of pulverised coal boiler flue gas furnace exit temperature
title_fullStr Investigation into methods for the calculation and measurement of pulverised coal boiler flue gas furnace exit temperature
title_full_unstemmed Investigation into methods for the calculation and measurement of pulverised coal boiler flue gas furnace exit temperature
title_short Investigation into methods for the calculation and measurement of pulverised coal boiler flue gas furnace exit temperature
title_sort investigation into methods for the calculation and measurement of pulverised coal boiler flue gas furnace exit temperature
topic Mechanical Engineering
Boiler furnace exit temperature
Mass and energy balances
Acoustic pyrometer
url http://hdl.handle.net/11427/20562
work_keys_str_mv AT tootlanaeemebrahim investigationintomethodsforthecalculationandmeasurementofpulverisedcoalboilerfluegasfurnaceexittemperature