Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

A patient-specific FSI model for vascular access in haemodialysis

This research forms part of an interdisciplinary project that aims to improve the understanding of haemodynamics and vascular mechanics in arteriovenous shunting. To achieve the high flow rates that enable patients with renal disease to receive haemodialysis, a fistula is created between an artery a...

Full description

Saved in:
Bibliographic Details
Main Author: De Villiers, Anna Magdalena
Other Authors: Reddy, B Daya
Format: Thesis
Language:English
Published: Centre for Research in Computational and Applied Mechanics (CERECAM) 2017
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613181683171328
access_status_str Open Access
author De Villiers, Anna Magdalena
author2 Reddy, B Daya
author_browse De Villiers, Anna Magdalena
Reddy, B Daya
author_facet Reddy, B Daya
De Villiers, Anna Magdalena
author_sort De Villiers, Anna Magdalena
collection Thesis
description This research forms part of an interdisciplinary project that aims to improve the understanding of haemodynamics and vascular mechanics in arteriovenous shunting. To achieve the high flow rates that enable patients with renal disease to receive haemodialysis, a fistula is created between an artery and a vein. The patency rate of fistulas, especially those located in the upper arm, is low. The approach adopted here makes use of new magnetic resonance image (MRI) technology and computational modelling of blood flow, with a view to improving therapeutic strategies of disease requiring vascular interventions. This thesis presents the construction and development of a 3D finite element model of the fluid-structure interaction in a brachial–cephalic patient–specific fistula. An overview of the mathematical models that describe the vessel wall and fluid behaviour as well their interaction with each other is given. An Arbitrary Lagrangian- Eulerian (ALE) framework is used together with a transversely isotropic hyperelastic constitutive model for the vessel walls, while blood flow is modelled as a Newtonian fluid. A three-element Windkessel model is used to allow the fluid to move through the outlets of the computational domain without causing non–physical reflections. Flow data acquired from MRI is used to prescribe the flow at the inlet. The parameters of the Windkessel-model at the two outlets are calibrated to resemble the flow acquired from the 2D MRI. The model is validated against the flow patterns acquired from the 4D MRI. The flow patterns of the blood, and stress present in the vessel are investigated. Of special significance are the flow and wall shear stress at the anastomosis. An area of very high velocity in the anastomosis is followed by an area of recirculation and low velocity. The propagation of pressure waves and their reflection at the anastomosis are studied. Areas that are subjected to low wall shear stress, high oscillatory wall shear stress or flow circulation are identified as areas where intimal hyperplasia may develop. The flow results from the simulation show good qualitative agreement with the MRI data.
format Thesis
id oai:open.uct.ac.za:11427/24441
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:32:03.909Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2017
publishDateRange 2017
publishDateSort 2017
publisher Centre for Research in Computational and Applied Mechanics (CERECAM)
publisherStr Centre for Research in Computational and Applied Mechanics (CERECAM)
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/24441 A patient-specific FSI model for vascular access in haemodialysis De Villiers, Anna Magdalena Reddy, B Daya McBride, Andrew Trevor Haemodynamics Vascular Mechanics This research forms part of an interdisciplinary project that aims to improve the understanding of haemodynamics and vascular mechanics in arteriovenous shunting. To achieve the high flow rates that enable patients with renal disease to receive haemodialysis, a fistula is created between an artery and a vein. The patency rate of fistulas, especially those located in the upper arm, is low. The approach adopted here makes use of new magnetic resonance image (MRI) technology and computational modelling of blood flow, with a view to improving therapeutic strategies of disease requiring vascular interventions. This thesis presents the construction and development of a 3D finite element model of the fluid-structure interaction in a brachial–cephalic patient–specific fistula. An overview of the mathematical models that describe the vessel wall and fluid behaviour as well their interaction with each other is given. An Arbitrary Lagrangian- Eulerian (ALE) framework is used together with a transversely isotropic hyperelastic constitutive model for the vessel walls, while blood flow is modelled as a Newtonian fluid. A three-element Windkessel model is used to allow the fluid to move through the outlets of the computational domain without causing non–physical reflections. Flow data acquired from MRI is used to prescribe the flow at the inlet. The parameters of the Windkessel-model at the two outlets are calibrated to resemble the flow acquired from the 2D MRI. The model is validated against the flow patterns acquired from the 4D MRI. The flow patterns of the blood, and stress present in the vessel are investigated. Of special significance are the flow and wall shear stress at the anastomosis. An area of very high velocity in the anastomosis is followed by an area of recirculation and low velocity. The propagation of pressure waves and their reflection at the anastomosis are studied. Areas that are subjected to low wall shear stress, high oscillatory wall shear stress or flow circulation are identified as areas where intimal hyperplasia may develop. The flow results from the simulation show good qualitative agreement with the MRI data. 2017-06-01T10:05:49Z 2017-06-01T10:05:49Z 2017 Doctoral Thesis Doctoral PhD http://hdl.handle.net/11427/24441 eng application/pdf Centre for Research in Computational and Applied Mechanics (CERECAM) Faculty of Engineering and the Built Environment University of Cape Town
spellingShingle Haemodynamics
Vascular Mechanics
De Villiers, Anna Magdalena
A patient-specific FSI model for vascular access in haemodialysis
thesis_degree_str Doctoral
title A patient-specific FSI model for vascular access in haemodialysis
title_full A patient-specific FSI model for vascular access in haemodialysis
title_fullStr A patient-specific FSI model for vascular access in haemodialysis
title_full_unstemmed A patient-specific FSI model for vascular access in haemodialysis
title_short A patient-specific FSI model for vascular access in haemodialysis
title_sort patient specific fsi model for vascular access in haemodialysis
topic Haemodynamics
Vascular Mechanics
url http://hdl.handle.net/11427/24441
work_keys_str_mv AT devilliersannamagdalena apatientspecificfsimodelforvascularaccessinhaemodialysis
AT devilliersannamagdalena patientspecificfsimodelforvascularaccessinhaemodialysis