Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

A numerical study of the suitability of rigid inclusion ground reinforcement beneath caisson quay walls

The objective of this study was to determine whether rigid inclusions are suitable for reinforcement of the foundation of a caisson quay wall functioning as a container terminal. Apart from their brittle behaviour under lateral loading, rigid inclusions are well suited to the large uniform loads and...

Full description

Saved in:
Bibliographic Details
Main Author: Holmwood, Andrew Graham
Other Authors: Kalumba, Denis
Format: Thesis
Language:English
Published: Department of Civil Engineering 2017
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613342365908992
access_status_str Open Access
author Holmwood, Andrew Graham
author2 Kalumba, Denis
author_browse Holmwood, Andrew Graham
Kalumba, Denis
author_facet Kalumba, Denis
Holmwood, Andrew Graham
author_sort Holmwood, Andrew Graham
collection Thesis
description The objective of this study was to determine whether rigid inclusions are suitable for reinforcement of the foundation of a caisson quay wall functioning as a container terminal. Apart from their brittle behaviour under lateral loading, rigid inclusions are well suited to the large uniform loads and stringent post-construction deflection tolerances associated with container terminal structures. Their inherent strength and stiffness means they have certain advantages over other stiffening columns commonly used for ground reinforcement in port expansion projects. Their mechanical properties allow construction to unrestricted heights at any construction rate and, in theory, RIs can be applied to all soil types. Additionally the locations of many ports coincide with rivers, deltas and estuaries which are associated with poor soil conditions often requiring ground improvement. Their suitability is of practical significance to port planners and engineers who are faced with the challenge of providing satisfactory foundation performance that is cost effective. The addition of RI ground reinforcement for this structural application would allow for greater flexibility in meeting these challenges. The literature review for this study was broad in its scope with emphasis placed on describing the mechanics of the problem, analysis methods and suitable installation methods for execution in the marine environment. One of the key outcomes of the literature review was identifying the problem of lateral loading due to "free-field" lateral ground movements. In light of this, suitable strategies for limiting and accommodating lateral loading of the RIs were proposed. A numerical study of the proposed ground improvement scheme was undertaken using the 3D finite element method. The key model outputs were caisson deflections and RI forces, moments and stresses, for the various simulated construction phases up to operational conditions. The model results were assessed in terms of the key foundation performance criteria which were related to STS crane rail tolerances and limiting tensile stresses in the RIs. This study found that for a firm clay subsoil condition the proposed RI ground reinforcement scheme met the foundation performance criteria for this structural application provided (i) strategies to limit lateral loading were implemented and (ii) the RIs were reinforced over the length where they were not fully compressed. While this study provided insights into the behaviour of RIs for this structural application, ultimately suitability is a function of range of factors, in addition to the limited technical performance criteria derived for this study.
format Thesis
id oai:open.uct.ac.za:11427/25283
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:34:36.552Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2017
publishDateRange 2017
publishDateSort 2017
publisher Department of Civil Engineering
publisherStr Department of Civil Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/25283 A numerical study of the suitability of rigid inclusion ground reinforcement beneath caisson quay walls Holmwood, Andrew Graham Kalumba, Denis Civil Engineering Structural Engineering The objective of this study was to determine whether rigid inclusions are suitable for reinforcement of the foundation of a caisson quay wall functioning as a container terminal. Apart from their brittle behaviour under lateral loading, rigid inclusions are well suited to the large uniform loads and stringent post-construction deflection tolerances associated with container terminal structures. Their inherent strength and stiffness means they have certain advantages over other stiffening columns commonly used for ground reinforcement in port expansion projects. Their mechanical properties allow construction to unrestricted heights at any construction rate and, in theory, RIs can be applied to all soil types. Additionally the locations of many ports coincide with rivers, deltas and estuaries which are associated with poor soil conditions often requiring ground improvement. Their suitability is of practical significance to port planners and engineers who are faced with the challenge of providing satisfactory foundation performance that is cost effective. The addition of RI ground reinforcement for this structural application would allow for greater flexibility in meeting these challenges. The literature review for this study was broad in its scope with emphasis placed on describing the mechanics of the problem, analysis methods and suitable installation methods for execution in the marine environment. One of the key outcomes of the literature review was identifying the problem of lateral loading due to "free-field" lateral ground movements. In light of this, suitable strategies for limiting and accommodating lateral loading of the RIs were proposed. A numerical study of the proposed ground improvement scheme was undertaken using the 3D finite element method. The key model outputs were caisson deflections and RI forces, moments and stresses, for the various simulated construction phases up to operational conditions. The model results were assessed in terms of the key foundation performance criteria which were related to STS crane rail tolerances and limiting tensile stresses in the RIs. This study found that for a firm clay subsoil condition the proposed RI ground reinforcement scheme met the foundation performance criteria for this structural application provided (i) strategies to limit lateral loading were implemented and (ii) the RIs were reinforced over the length where they were not fully compressed. While this study provided insights into the behaviour of RIs for this structural application, ultimately suitability is a function of range of factors, in addition to the limited technical performance criteria derived for this study. 2017-09-22T11:58:48Z 2017-09-22T11:58:48Z 2017 Master Thesis Masters MSc (Eng) http://hdl.handle.net/11427/25283 eng application/pdf Department of Civil Engineering Faculty of Engineering and the Built Environment University of Cape Town
spellingShingle Civil Engineering
Structural Engineering
Holmwood, Andrew Graham
A numerical study of the suitability of rigid inclusion ground reinforcement beneath caisson quay walls
thesis_degree_str Master's
title A numerical study of the suitability of rigid inclusion ground reinforcement beneath caisson quay walls
title_full A numerical study of the suitability of rigid inclusion ground reinforcement beneath caisson quay walls
title_fullStr A numerical study of the suitability of rigid inclusion ground reinforcement beneath caisson quay walls
title_full_unstemmed A numerical study of the suitability of rigid inclusion ground reinforcement beneath caisson quay walls
title_short A numerical study of the suitability of rigid inclusion ground reinforcement beneath caisson quay walls
title_sort numerical study of the suitability of rigid inclusion ground reinforcement beneath caisson quay walls
topic Civil Engineering
Structural Engineering
url http://hdl.handle.net/11427/25283
work_keys_str_mv AT holmwoodandrewgraham anumericalstudyofthesuitabilityofrigidinclusiongroundreinforcementbeneathcaissonquaywalls
AT holmwoodandrewgraham numericalstudyofthesuitabilityofrigidinclusiongroundreinforcementbeneathcaissonquaywalls