The neutron sensitivities of Geiger-Müller counters

Neutron beams are always accompanied by gamma rays. Because neutrons and gamma rays have different biological effects, it is essential that the neutron and gamma dose components be determined when neutron beams are used for radiotherapy and radiobiology. Since gamma ray dosimeters almost always also...

Full description

Saved in:
Bibliographic Details
Main Author: Jones, D T L
Format: Thesis
Language:English
Published: Division of Medical Physics 2017
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613170934218752
access_status_str Open Access
author Jones, D T L
author_browse Jones, D T L
author_facet Jones, D T L
author_sort Jones, D T L
collection Thesis
description Neutron beams are always accompanied by gamma rays. Because neutrons and gamma rays have different biological effects, it is essential that the neutron and gamma dose components be determined when neutron beams are used for radiotherapy and radiobiology. Since gamma ray dosimeters almost always also respond to neutrons, it is generally not possible to use two different devices to measure the separate dose components. The separate doses are usually determined by making measurements with two instruments which have different sensitivities to the two types of radiation and deducing the separate components from these measurements. One instrument usually has approximately equal sensitivity to both neutrons and gamma rays while the other has a low sensitivity to neutrons. The latter instrument is often a Geiger-Müller (G-M) counter. Although its neutron sensitivity (kᵤ) is low, it must be measured for accurate dose determinations. Previous u measurements of the neutron sensitivities of such counters have not always been in good agreement. In the present work the neutron sensitivities of two types of G-M counters, viz. ZP1320 and ZP1300 have been measured at neutron energies between 0.72 and 7.42 MeV. An absolute measurement of the neutron sensitivity of the ZP1320 counter was made at 3 MeV using the associated particle technique while the neutron sensitivities of both counters were measured at several energies using the pulsed beam time-of-flight technique. For the latter measurements a NE213 scintillation counter was used to measure the neutron flux. The detection efficiencies of this counter were calculated and the validity of the calculations were confirmed by measurements using the associated particle technique. The neutron sensitivities obtained in the present work are in reasonable agreement with most previous measurements. All available data for similar types of counters were fitted with a function of the form kᵤ(E) = a Eᵇ. The values of the fitting parameters were ZP1320 (0.72 to 7.42 MeV) : a = 0.10 ± 0.01, b = 1.32 ± 0.05 and ZP1300 (0.57 to 15.65 MeV) a = 0.25 ± 0.01, b = 1.32 -+ 0.05 b = 0.78 ± 0.03.
format Thesis
id oai:open.uct.ac.za:11427/26529
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:31:53.390Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2017
publishDateRange 2017
publishDateSort 2017
publisher Division of Medical Physics
publisherStr Division of Medical Physics
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/26529 The neutron sensitivities of Geiger-Müller counters Jones, D T L Medical Physics Neutron beams are always accompanied by gamma rays. Because neutrons and gamma rays have different biological effects, it is essential that the neutron and gamma dose components be determined when neutron beams are used for radiotherapy and radiobiology. Since gamma ray dosimeters almost always also respond to neutrons, it is generally not possible to use two different devices to measure the separate dose components. The separate doses are usually determined by making measurements with two instruments which have different sensitivities to the two types of radiation and deducing the separate components from these measurements. One instrument usually has approximately equal sensitivity to both neutrons and gamma rays while the other has a low sensitivity to neutrons. The latter instrument is often a Geiger-Müller (G-M) counter. Although its neutron sensitivity (kᵤ) is low, it must be measured for accurate dose determinations. Previous u measurements of the neutron sensitivities of such counters have not always been in good agreement. In the present work the neutron sensitivities of two types of G-M counters, viz. ZP1320 and ZP1300 have been measured at neutron energies between 0.72 and 7.42 MeV. An absolute measurement of the neutron sensitivity of the ZP1320 counter was made at 3 MeV using the associated particle technique while the neutron sensitivities of both counters were measured at several energies using the pulsed beam time-of-flight technique. For the latter measurements a NE213 scintillation counter was used to measure the neutron flux. The detection efficiencies of this counter were calculated and the validity of the calculations were confirmed by measurements using the associated particle technique. The neutron sensitivities obtained in the present work are in reasonable agreement with most previous measurements. All available data for similar types of counters were fitted with a function of the form kᵤ(E) = a Eᵇ. The values of the fitting parameters were ZP1320 (0.72 to 7.42 MeV) : a = 0.10 ± 0.01, b = 1.32 ± 0.05 and ZP1300 (0.57 to 15.65 MeV) a = 0.25 ± 0.01, b = 1.32 -+ 0.05 b = 0.78 ± 0.03. 2017-12-11T10:17:30Z 2017-12-11T10:17:30Z 1984 Master Thesis Masters MSc (Med) http://hdl.handle.net/11427/26529 eng application/pdf Division of Medical Physics Faculty of Health Sciences University of Cape Town
spellingShingle Medical Physics
Jones, D T L
The neutron sensitivities of Geiger-Müller counters
thesis_degree_str Master's
title The neutron sensitivities of Geiger-Müller counters
title_full The neutron sensitivities of Geiger-Müller counters
title_fullStr The neutron sensitivities of Geiger-Müller counters
title_full_unstemmed The neutron sensitivities of Geiger-Müller counters
title_short The neutron sensitivities of Geiger-Müller counters
title_sort neutron sensitivities of geiger muller counters
topic Medical Physics
url http://hdl.handle.net/11427/26529
work_keys_str_mv AT jonesdtl theneutronsensitivitiesofgeigermullercounters
AT jonesdtl neutronsensitivitiesofgeigermullercounters