Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid

With the growing use of non-linear loads and due to their ever changing nature, electricity networks experience power imbalance continually. These non-linear asymmetrical loads draw distorted unbalanced currents and voltages at the point of common coupling (PCC) which propagate into the distribution...

Full description

Saved in:
Bibliographic Details
Main Author: Khan, Akrama
Other Authors: Khan, Mohamed
Format: Thesis
Language:English
Published: Department of Electrical Engineering 2020
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613297245683712
access_status_str Open Access
author Khan, Akrama
author2 Khan, Mohamed
author_browse Khan, Akrama
Khan, Mohamed
author_facet Khan, Mohamed
Khan, Akrama
author_sort Khan, Akrama
collection Thesis
description With the growing use of non-linear loads and due to their ever changing nature, electricity networks experience power imbalance continually. These non-linear asymmetrical loads draw distorted unbalanced currents and voltages at the point of common coupling (PCC) which propagate into the distribution network. Power quality has therefore become an important issue, which has resulted in the development of numerous control strategies and other interventions to maintain the integrity of the electric network. Recent advancements in power electronics have provided new ways to optimize power systems by regulating the active power transfer. These developments lead to opportunities for renewable energy systems to harness energy and at the same time inject optimized currents into the network by means of distributed units. An emerging problem with most such units is that they are located far from the PCC and are usually designed for the small linear loads. Moreover, the problem is exacerbated during overload conditions when the voltage level drops below the allowed minimum level due to the high network impedance which characterizes a weak grid. This thesis aims to study similar scenarios where a permanent magnet synchronous generator (PMSG) based wind energy conversion system (WECS) is integrated into a weak AC grid. The system comprises of a machine-side (MSC) and a grid-side (GSC) converter, which provides available ancillary services and is envisaged to augment existing power quality conditioners such as STATCOM devices. To represent a weak grid, a Thevenin equivalent model of the electric network is considered with unbalanced loads. The main objective of this project is to transform the traditional converter topology into a versatile system that can perform as a power conditioner. In particular, it monitors a distribution line, sense changes in the load, detects faults and redistributes the currents to ensure maximized power transfer into the network. The system under consideration possesses the capability of independent injection of active and reactive currents within the defined limits. Since the system under consideration is integrated v into a weak grid, the perceived load is always considered to be unbalanced. Under the specified condition, if a fault occurs at one or two phases, unbalanced voltages are observed at the PCC. Two scenarios are created to perform the case study. Firstly, a no-fault case is considered with symmetrical voltages at the PCC. To ensure maximum power transfer into the network with least losses, a set of currents is injected according to the optimal current injection technique. Secondly, asymmetrical faults are considered at the PCC and currents are injected according to the coordinated sequence current injection technique. This technique defines a new current injection limit which not only improves the power transfer but also enhances the power factor. Furthermore, the peak magnitude of the three phase currents is also kept within the rated current limit. For both scenarios described above, the MSC regulates the DC link voltage so as to limit the active power coming from the generator according to the grid condition. The GSC however performs two important functions. It implements small active/reactive power perturbations for the impedance estimation, and once the impedances are determined, magnitudes of the required currents are calculated and injected based on the proposed techniques. Validation of the analysis is done experimentally on a 3.3kW PMSG connected to a programmable regenerative power supply which emulates a weak grid. The MSC and GSC utilized in this project are conventional two-level converters which are controlled by means of a FPGA based controller.
format Thesis
id oai:open.uct.ac.za:11427/32243
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:33:54.099Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2020
publishDateRange 2020
publishDateSort 2020
publisher Department of Electrical Engineering
publisherStr Department of Electrical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/32243 Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid Khan, Akrama Khan, Mohamed Malengret Michel electrical engineering With the growing use of non-linear loads and due to their ever changing nature, electricity networks experience power imbalance continually. These non-linear asymmetrical loads draw distorted unbalanced currents and voltages at the point of common coupling (PCC) which propagate into the distribution network. Power quality has therefore become an important issue, which has resulted in the development of numerous control strategies and other interventions to maintain the integrity of the electric network. Recent advancements in power electronics have provided new ways to optimize power systems by regulating the active power transfer. These developments lead to opportunities for renewable energy systems to harness energy and at the same time inject optimized currents into the network by means of distributed units. An emerging problem with most such units is that they are located far from the PCC and are usually designed for the small linear loads. Moreover, the problem is exacerbated during overload conditions when the voltage level drops below the allowed minimum level due to the high network impedance which characterizes a weak grid. This thesis aims to study similar scenarios where a permanent magnet synchronous generator (PMSG) based wind energy conversion system (WECS) is integrated into a weak AC grid. The system comprises of a machine-side (MSC) and a grid-side (GSC) converter, which provides available ancillary services and is envisaged to augment existing power quality conditioners such as STATCOM devices. To represent a weak grid, a Thevenin equivalent model of the electric network is considered with unbalanced loads. The main objective of this project is to transform the traditional converter topology into a versatile system that can perform as a power conditioner. In particular, it monitors a distribution line, sense changes in the load, detects faults and redistributes the currents to ensure maximized power transfer into the network. The system under consideration possesses the capability of independent injection of active and reactive currents within the defined limits. Since the system under consideration is integrated v into a weak grid, the perceived load is always considered to be unbalanced. Under the specified condition, if a fault occurs at one or two phases, unbalanced voltages are observed at the PCC. Two scenarios are created to perform the case study. Firstly, a no-fault case is considered with symmetrical voltages at the PCC. To ensure maximum power transfer into the network with least losses, a set of currents is injected according to the optimal current injection technique. Secondly, asymmetrical faults are considered at the PCC and currents are injected according to the coordinated sequence current injection technique. This technique defines a new current injection limit which not only improves the power transfer but also enhances the power factor. Furthermore, the peak magnitude of the three phase currents is also kept within the rated current limit. For both scenarios described above, the MSC regulates the DC link voltage so as to limit the active power coming from the generator according to the grid condition. The GSC however performs two important functions. It implements small active/reactive power perturbations for the impedance estimation, and once the impedances are determined, magnitudes of the required currents are calculated and injected based on the proposed techniques. Validation of the analysis is done experimentally on a 3.3kW PMSG connected to a programmable regenerative power supply which emulates a weak grid. The MSC and GSC utilized in this project are conventional two-level converters which are controlled by means of a FPGA based controller. 2020-09-13T19:21:10Z 2020-09-13T19:21:10Z 2020 2020-09-13T19:18:31Z Doctoral Thesis Doctoral PhD http://hdl.handle.net/11427/32243 eng application/pdf Department of Electrical Engineering Faculty of Engineering and the Built Environment
spellingShingle electrical engineering
Khan, Akrama
Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid
thesis_degree_str Doctoral
title Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid
title_full Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid
title_fullStr Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid
title_full_unstemmed Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid
title_short Development of a power conditioner for a PMSG-based wind energy system integrated into a weak grid
title_sort development of a power conditioner for a pmsg based wind energy system integrated into a weak grid
topic electrical engineering
url http://hdl.handle.net/11427/32243
work_keys_str_mv AT khanakrama developmentofapowerconditionerforapmsgbasedwindenergysystemintegratedintoaweakgrid