Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Ultrasonography Evaluation of Patency of Implanted Infra-Renal Vascular Grafts in the Rat Model.

Introduction: Intensive research over the last six decades has resulted in minimal improvement in vascular graft development. Small animal models are the first line of species exposed to vascular graft implantation and invasive monitoring of experimental graft patency may contribute to pain, sufferi...

Full description

Saved in:
Bibliographic Details
Main Author: Da Silva, Natercia
Other Authors: Pennel, Timothy
Format: Thesis
Language:English
Published: Division of Cardiothoracic Surgery 2021
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613282851880960
access_status_str Open Access
author Da Silva, Natercia
author2 Pennel, Timothy
author_browse Da Silva, Natercia
Pennel, Timothy
author_facet Pennel, Timothy
Da Silva, Natercia
author_sort Da Silva, Natercia
collection Thesis
description Introduction: Intensive research over the last six decades has resulted in minimal improvement in vascular graft development. Small animal models are the first line of species exposed to vascular graft implantation and invasive monitoring of experimental graft patency may contribute to pain, suffering, higher cost and earlier sacrifice. Non-invasive ultrasonographic evaluation of vascular implants during the conduction of animal studies allows for chronic follow-up with multiple assessments. This study aims to apply and endorse the utilization of ultrasound as a less invasive diagnostic method in determining patency of vascular grafts in units where imaging modalities like Computerized Tomography (CT) and Magnetic Resonance Imaging (MRI) are not readily available. Methods: Pre-operative control ultrasound evaluation of the ejection fraction, aortic diameter and aortic velocity were conducted on Wistar rats (250-350g). Infra-renal aortic vascular graft implantation was then performed, with 8 rats receiving straight (1.8mm ID, 18mm length) expanded polytetrafluoroethylene (ePTFE) grafts, while 12 rats received a long (1.8mm ID, 100mm length) looped ePTFE conduit with a sealed mid-graft (10mm length) section. Ultrasonography was conducted on days 1, 3, 7 and weeks 4, 8 and 12 post operatively. Grafts were explanted if there was any ultrasonographic evidence of occlusion or at twelveweek termination of the study. Explant was preceded by angiography and followed by histological assessment of the grafts for patency. Results: Three of the looped and all 8 of the straight grafts were patent at the 12 week explant time point, as correctly assessed by ultrasound and confirmed by angiography and histology. Three of the nine occluded looped grafts were explanted at eight weeks due to early ultrasonographic detection of occlusion; the remaining 6 were explanted at twelve weeks. There were two false positive results, which were incorrectly assessed as patent at twelve weeks of implantation on ultrasonographic evaluation, but confirmed to be occluded on angiography at explant. The results of ultrasonography evaluation of implanted infra-renal vascular grafts had a high specificity of 100% with a sensitivity of 78%. The outcome of the results between ultrasound and angiography corresponded in 18 out of 20 vascular grafts, with a calculated positive predictive value (PPV) of 100% and a negative predictive value (NPV) of 85%. 4 Conclusion: Ultrasound is easily available and a non-invasive diagnostic modality allowing for safe and reliable results, which may be repeated at different time frames following vascular implants in small animal models. Ultrasonographic limitations exist, emphasizing the need for an experienced operator with adequate knowledge and training. Its use may be complicated by tortuous geometries of vessels, which is technically more challenging to evaluate with ultrasound than with imaging techniques like CT and MRI. It does, however, add information without additional loss of life or increased use of animal numbers. Ultrasound is an essential additive diagnostic tool for chronic follow-up and evaluation of vascular graft implants.
format Thesis
id oai:open.uct.ac.za:11427/32616
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:33:40.116Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2021
publishDateRange 2021
publishDateSort 2021
publisher Division of Cardiothoracic Surgery
publisherStr Division of Cardiothoracic Surgery
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/32616 Ultrasonography Evaluation of Patency of Implanted Infra-Renal Vascular Grafts in the Rat Model. Da Silva, Natercia Pennel, Timothy Bezuidenhout, Deon Hadebe, Nkanyiso Zilla, Peter Cardiothoracic Surgery Introduction: Intensive research over the last six decades has resulted in minimal improvement in vascular graft development. Small animal models are the first line of species exposed to vascular graft implantation and invasive monitoring of experimental graft patency may contribute to pain, suffering, higher cost and earlier sacrifice. Non-invasive ultrasonographic evaluation of vascular implants during the conduction of animal studies allows for chronic follow-up with multiple assessments. This study aims to apply and endorse the utilization of ultrasound as a less invasive diagnostic method in determining patency of vascular grafts in units where imaging modalities like Computerized Tomography (CT) and Magnetic Resonance Imaging (MRI) are not readily available. Methods: Pre-operative control ultrasound evaluation of the ejection fraction, aortic diameter and aortic velocity were conducted on Wistar rats (250-350g). Infra-renal aortic vascular graft implantation was then performed, with 8 rats receiving straight (1.8mm ID, 18mm length) expanded polytetrafluoroethylene (ePTFE) grafts, while 12 rats received a long (1.8mm ID, 100mm length) looped ePTFE conduit with a sealed mid-graft (10mm length) section. Ultrasonography was conducted on days 1, 3, 7 and weeks 4, 8 and 12 post operatively. Grafts were explanted if there was any ultrasonographic evidence of occlusion or at twelveweek termination of the study. Explant was preceded by angiography and followed by histological assessment of the grafts for patency. Results: Three of the looped and all 8 of the straight grafts were patent at the 12 week explant time point, as correctly assessed by ultrasound and confirmed by angiography and histology. Three of the nine occluded looped grafts were explanted at eight weeks due to early ultrasonographic detection of occlusion; the remaining 6 were explanted at twelve weeks. There were two false positive results, which were incorrectly assessed as patent at twelve weeks of implantation on ultrasonographic evaluation, but confirmed to be occluded on angiography at explant. The results of ultrasonography evaluation of implanted infra-renal vascular grafts had a high specificity of 100% with a sensitivity of 78%. The outcome of the results between ultrasound and angiography corresponded in 18 out of 20 vascular grafts, with a calculated positive predictive value (PPV) of 100% and a negative predictive value (NPV) of 85%. 4 Conclusion: Ultrasound is easily available and a non-invasive diagnostic modality allowing for safe and reliable results, which may be repeated at different time frames following vascular implants in small animal models. Ultrasonographic limitations exist, emphasizing the need for an experienced operator with adequate knowledge and training. Its use may be complicated by tortuous geometries of vessels, which is technically more challenging to evaluate with ultrasound than with imaging techniques like CT and MRI. It does, however, add information without additional loss of life or increased use of animal numbers. Ultrasound is an essential additive diagnostic tool for chronic follow-up and evaluation of vascular graft implants. 2021-01-21T07:42:07Z 2021-01-21T07:42:07Z 2020 2021-01-21T07:27:37Z Master Thesis Masters MMed http://hdl.handle.net/11427/32616 eng application/pdf Division of Cardiothoracic Surgery Faculty of Health Sciences
spellingShingle Cardiothoracic Surgery
Da Silva, Natercia
Ultrasonography Evaluation of Patency of Implanted Infra-Renal Vascular Grafts in the Rat Model.
thesis_degree_str Master's
title Ultrasonography Evaluation of Patency of Implanted Infra-Renal Vascular Grafts in the Rat Model.
title_full Ultrasonography Evaluation of Patency of Implanted Infra-Renal Vascular Grafts in the Rat Model.
title_fullStr Ultrasonography Evaluation of Patency of Implanted Infra-Renal Vascular Grafts in the Rat Model.
title_full_unstemmed Ultrasonography Evaluation of Patency of Implanted Infra-Renal Vascular Grafts in the Rat Model.
title_short Ultrasonography Evaluation of Patency of Implanted Infra-Renal Vascular Grafts in the Rat Model.
title_sort ultrasonography evaluation of patency of implanted infra renal vascular grafts in the rat model
topic Cardiothoracic Surgery
url http://hdl.handle.net/11427/32616
work_keys_str_mv AT dasilvanatercia ultrasonographyevaluationofpatencyofimplantedinfrarenalvasculargraftsintheratmodel