Design, manufacture and commissioning of a low pressure quasistatic bulge tester for skin and membrane tissue

The material properties of skin are of great importance to a variety of fields such as dermatology and reconstructive surgery. Relatively little infrastructure and expertise exists locally in South Africa for testing biological tissue. The difficulties of testing the material properties of skin are...

Full description

Saved in:
Bibliographic Details
Main Author: Curry, Andrew Michael
Other Authors: Govender, Reuben
Format: Thesis
Language:English
Published: Department of Mechanical Engineering 2021
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613182835556352
access_status_str Open Access
author Curry, Andrew Michael
author2 Govender, Reuben
author_browse Curry, Andrew Michael
Govender, Reuben
author_facet Govender, Reuben
Curry, Andrew Michael
author_sort Curry, Andrew Michael
collection Thesis
description The material properties of skin are of great importance to a variety of fields such as dermatology and reconstructive surgery. Relatively little infrastructure and expertise exists locally in South Africa for testing biological tissue. The difficulties of testing the material properties of skin are the non-uniformity and anisotropy across specimen location and subjects. This anisotropy is most commonly measured by tensile testing of samples cut in different orientations. However, the individual samples at different orientations would be extracted from slightly different locations on the same subject, which will naturally vary in response. Bulge testing is a method of determining response to tension in different directions at the same location, by applying biaxial tension. It uses a positive pressure applied to a peripherally clamped specimen to deform the specimen in a balloon type manner. In this project, bulge testing apparatus was designed and built for the purpose of testing skin and membrane tissue, under biaxial tension. The testing apparatus consists of a syringe pump to control inflation of a specimen, which is clamped in an inflation chamber. Digital Image Correlation (DIC) was used to capture the 3D deformation fields of the specimen, and hence infer the strain fields. To simplify commissioning testing, a commercial silicone elastomer suited for skin prosthetics, was used to manufacture specimens for uniaxial and bulge experimental testing. Two types of bulge specimens were manufactured, standard round specimens and elliptical specimens. The round specimens were used to compare their material response to uniaxial tests and the elliptical bulge specimens were used to simulate the anisotropic response of skin. The method of analysis used in this project is based on using DIC and curvature calculations at multiple points to calculate membrane stresses in principal directions. The method of calculating principal curvatures from DIC is adapted from the work by Machado et al. [1] that calculated Gaussian curvature using the first and second fundamental forms of a surface. In total 18 round, 6 elliptical and 10 uniaxial specimens were tested and the material properties were found to vary slightly between each specimen. The spread in data between the uniaxial and bulge tests was found to be very similar with the bulge data showing 10 % spread at 1.2 stretch and constant 8 % spread above 1.2 stretch and the uniaxial data showing increasing spread from 7 % to 15 %. The curvature results showed very clear principal directions of curvature for the elliptical specimens. This demonstrated that the method used in this project is capable of clearly extracting the orientations of stiffer fibre directions of skin and other collagenous tissue.
format Thesis
id oai:open.uct.ac.za:11427/32689
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:32:05.102Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2021
publishDateRange 2021
publishDateSort 2021
publisher Department of Mechanical Engineering
publisherStr Department of Mechanical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/32689 Design, manufacture and commissioning of a low pressure quasistatic bulge tester for skin and membrane tissue Curry, Andrew Michael Govender, Reuben Nurick, Gerald Mechanical Engineering The material properties of skin are of great importance to a variety of fields such as dermatology and reconstructive surgery. Relatively little infrastructure and expertise exists locally in South Africa for testing biological tissue. The difficulties of testing the material properties of skin are the non-uniformity and anisotropy across specimen location and subjects. This anisotropy is most commonly measured by tensile testing of samples cut in different orientations. However, the individual samples at different orientations would be extracted from slightly different locations on the same subject, which will naturally vary in response. Bulge testing is a method of determining response to tension in different directions at the same location, by applying biaxial tension. It uses a positive pressure applied to a peripherally clamped specimen to deform the specimen in a balloon type manner. In this project, bulge testing apparatus was designed and built for the purpose of testing skin and membrane tissue, under biaxial tension. The testing apparatus consists of a syringe pump to control inflation of a specimen, which is clamped in an inflation chamber. Digital Image Correlation (DIC) was used to capture the 3D deformation fields of the specimen, and hence infer the strain fields. To simplify commissioning testing, a commercial silicone elastomer suited for skin prosthetics, was used to manufacture specimens for uniaxial and bulge experimental testing. Two types of bulge specimens were manufactured, standard round specimens and elliptical specimens. The round specimens were used to compare their material response to uniaxial tests and the elliptical bulge specimens were used to simulate the anisotropic response of skin. The method of analysis used in this project is based on using DIC and curvature calculations at multiple points to calculate membrane stresses in principal directions. The method of calculating principal curvatures from DIC is adapted from the work by Machado et al. [1] that calculated Gaussian curvature using the first and second fundamental forms of a surface. In total 18 round, 6 elliptical and 10 uniaxial specimens were tested and the material properties were found to vary slightly between each specimen. The spread in data between the uniaxial and bulge tests was found to be very similar with the bulge data showing 10 % spread at 1.2 stretch and constant 8 % spread above 1.2 stretch and the uniaxial data showing increasing spread from 7 % to 15 %. The curvature results showed very clear principal directions of curvature for the elliptical specimens. This demonstrated that the method used in this project is capable of clearly extracting the orientations of stiffer fibre directions of skin and other collagenous tissue. 2021-01-27T05:49:00Z 2021-01-27T05:49:00Z 2020 2021-01-26T17:28:23Z Master Thesis Masters MSc http://hdl.handle.net/11427/32689 eng application/pdf Department of Mechanical Engineering Faculty of Engineering and the Built Environment
spellingShingle Mechanical Engineering
Curry, Andrew Michael
Design, manufacture and commissioning of a low pressure quasistatic bulge tester for skin and membrane tissue
thesis_degree_str Master's
title Design, manufacture and commissioning of a low pressure quasistatic bulge tester for skin and membrane tissue
title_full Design, manufacture and commissioning of a low pressure quasistatic bulge tester for skin and membrane tissue
title_fullStr Design, manufacture and commissioning of a low pressure quasistatic bulge tester for skin and membrane tissue
title_full_unstemmed Design, manufacture and commissioning of a low pressure quasistatic bulge tester for skin and membrane tissue
title_short Design, manufacture and commissioning of a low pressure quasistatic bulge tester for skin and membrane tissue
title_sort design manufacture and commissioning of a low pressure quasistatic bulge tester for skin and membrane tissue
topic Mechanical Engineering
url http://hdl.handle.net/11427/32689
work_keys_str_mv AT curryandrewmichael designmanufactureandcommissioningofalowpressurequasistaticbulgetesterforskinandmembranetissue