Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

A comparison of the accuracy of various methods of postnatal gestational age estimation; including Ballard score, foot length, vascularity of the anterior lens, last menstrual period and also a clinician's non-structured assessment

Rationale Gestational age is a strong determinant of neonatal mortality and morbidity. Early obstetric ultrasound is the clinical reference standard, but is not widely available in many developing countries. There is a well recognised need to identify reliable and simple methods of postnatal gestati...

Full description

Saved in:
Bibliographic Details
Main Author: Stevenson, Alexander Graham
Other Authors: Tooke, Lloyd
Format: Thesis
Language:English
Published: Department of Paediatrics and Child Health 2021
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613148246179840
access_status_str Open Access
author Stevenson, Alexander Graham
author2 Tooke, Lloyd
author_browse Stevenson, Alexander Graham
Tooke, Lloyd
author_facet Tooke, Lloyd
Stevenson, Alexander Graham
author_sort Stevenson, Alexander Graham
collection Thesis
description Rationale Gestational age is a strong determinant of neonatal mortality and morbidity. Early obstetric ultrasound is the clinical reference standard, but is not widely available in many developing countries. There is a well recognised need to identify reliable and simple methods of postnatal gestational age estimation. Methods A prospectively designed methods comparison study in a tertiary referral hospital in a developing country. Early ultrasound (<20 weeks) was the clinical reference standard. Methods evaluated included anthropometric measurements (including foot-length), vascularity of the anterior lens, the New Ballard Score and Last Menstrual Period. Clinicians' non-structured global impression “End of Bed” Assessment was also evaluated. Results 106 babies were included in the study. Median age at birth was 34 weeks (IQR 29-36). Ballard Score and “End of Bed” Assessment had a mean bias of -0.14 and 0.06 weeks respectively but wide 95% limits of agreement. The physical component of the Ballard score, the total Ballard score and Foot-length's ability to discriminate between term and preterm infants gave an AUROC of 0.97, 0.96 and 0.95 respectively. Discussion Although “End of Bed” Assessment and Ballard score had small mean biases, the wide confidence intervals render the methods irrelevant in clinical practice. Foot-length was particularly poor in Small for Gestational Age infants. None of the methods studied were superior to a non-structured clinician's informal “End of Bed” Assessment. Conclusion None of the methods studied met the a priori definition of clinical usefulness. Improving access to early ultrasound remains a priority. Instead of focusing on chronological accuracy, future research should compare the ability of early ultrasound and Ballard score to predict morbidity and mortality.
format Thesis
id oai:open.uct.ac.za:11427/33997
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:31:31.816Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2021
publishDateRange 2021
publishDateSort 2021
publisher Department of Paediatrics and Child Health
publisherStr Department of Paediatrics and Child Health
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/33997 A comparison of the accuracy of various methods of postnatal gestational age estimation; including Ballard score, foot length, vascularity of the anterior lens, last menstrual period and also a clinician's non-structured assessment Stevenson, Alexander Graham Tooke, Lloyd Joolay, Yaseen Child Health Rationale Gestational age is a strong determinant of neonatal mortality and morbidity. Early obstetric ultrasound is the clinical reference standard, but is not widely available in many developing countries. There is a well recognised need to identify reliable and simple methods of postnatal gestational age estimation. Methods A prospectively designed methods comparison study in a tertiary referral hospital in a developing country. Early ultrasound (<20 weeks) was the clinical reference standard. Methods evaluated included anthropometric measurements (including foot-length), vascularity of the anterior lens, the New Ballard Score and Last Menstrual Period. Clinicians' non-structured global impression “End of Bed” Assessment was also evaluated. Results 106 babies were included in the study. Median age at birth was 34 weeks (IQR 29-36). Ballard Score and “End of Bed” Assessment had a mean bias of -0.14 and 0.06 weeks respectively but wide 95% limits of agreement. The physical component of the Ballard score, the total Ballard score and Foot-length's ability to discriminate between term and preterm infants gave an AUROC of 0.97, 0.96 and 0.95 respectively. Discussion Although “End of Bed” Assessment and Ballard score had small mean biases, the wide confidence intervals render the methods irrelevant in clinical practice. Foot-length was particularly poor in Small for Gestational Age infants. None of the methods studied were superior to a non-structured clinician's informal “End of Bed” Assessment. Conclusion None of the methods studied met the a priori definition of clinical usefulness. Improving access to early ultrasound remains a priority. Instead of focusing on chronological accuracy, future research should compare the ability of early ultrasound and Ballard score to predict morbidity and mortality. 2021-09-22T14:46:42Z 2021-09-22T14:46:42Z 2020 2021-09-22T14:46:00Z Master Thesis Masters MPhil http://hdl.handle.net/11427/33997 eng application/pdf Department of Paediatrics and Child Health Faculty of Health Sciences
spellingShingle Child Health
Stevenson, Alexander Graham
A comparison of the accuracy of various methods of postnatal gestational age estimation; including Ballard score, foot length, vascularity of the anterior lens, last menstrual period and also a clinician's non-structured assessment
thesis_degree_str Master's
title A comparison of the accuracy of various methods of postnatal gestational age estimation; including Ballard score, foot length, vascularity of the anterior lens, last menstrual period and also a clinician's non-structured assessment
title_full A comparison of the accuracy of various methods of postnatal gestational age estimation; including Ballard score, foot length, vascularity of the anterior lens, last menstrual period and also a clinician's non-structured assessment
title_fullStr A comparison of the accuracy of various methods of postnatal gestational age estimation; including Ballard score, foot length, vascularity of the anterior lens, last menstrual period and also a clinician's non-structured assessment
title_full_unstemmed A comparison of the accuracy of various methods of postnatal gestational age estimation; including Ballard score, foot length, vascularity of the anterior lens, last menstrual period and also a clinician's non-structured assessment
title_short A comparison of the accuracy of various methods of postnatal gestational age estimation; including Ballard score, foot length, vascularity of the anterior lens, last menstrual period and also a clinician's non-structured assessment
title_sort comparison of the accuracy of various methods of postnatal gestational age estimation including ballard score foot length vascularity of the anterior lens last menstrual period and also a clinician s non structured assessment
topic Child Health
url http://hdl.handle.net/11427/33997
work_keys_str_mv AT stevensonalexandergraham acomparisonoftheaccuracyofvariousmethodsofpostnatalgestationalageestimationincludingballardscorefootlengthvascularityoftheanteriorlenslastmenstrualperiodandalsoacliniciansnonstructuredassessment
AT stevensonalexandergraham comparisonoftheaccuracyofvariousmethodsofpostnatalgestationalageestimationincludingballardscorefootlengthvascularityoftheanteriorlenslastmenstrualperiodandalsoacliniciansnonstructuredassessment