Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Multi-photon decay mode spectroscopy of positronium

An approximation for the branching ratio of the four-photon decay of parapositronium (BR4γ) was measured using a multi-gamma-ray spectrometer. For the first time in such measurements, the spectrometer consisted of an array of eight identical LaBr3:Ce scintillator detectors, each of which combines go...

Full description

Saved in:
Bibliographic Details
Main Author: Johnson, Storm
Other Authors: Leadbeater, Thomas
Format: Thesis
Language:English
Published: Department of Physics 2022
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867614092324241408
access_status_str Open Access
author Johnson, Storm
author2 Leadbeater, Thomas
author_browse Johnson, Storm
Leadbeater, Thomas
author_facet Leadbeater, Thomas
Johnson, Storm
author_sort Johnson, Storm
collection Thesis
description An approximation for the branching ratio of the four-photon decay of parapositronium (BR4γ) was measured using a multi-gamma-ray spectrometer. For the first time in such measurements, the spectrometer consisted of an array of eight identical LaBr3:Ce scintillator detectors, each of which combines good energy resolutions (5% and 10% at 511 keV for the signals from the eighth dynode and anode of the photomultiplier tube, respectively) with an excellent timing resolution (∼ 300 ps). These energy resolutions were minimised through an optimal selection of the digital signal processing parameter settings. The detectors were situated in a planar geometry, where the source-to-detector distance of the detector system was selected such that the effect of peak pulse pile-up was minimised (to less than 3%), while maximising the full-energy peak detection efficiency at 511 keV (to 3%). For this work, locally-produced 22Na radioactive sources were used as positron emitters, which enabled the formation of positronium and subsequent gamma decays. Energy calibration measurements were performed using a 152Eu source, where the prominent energy peaks of (121.8, 244.7, 344.3, 778.9, 964.1, 1408.0) keV were used for calibration. For the BR4γ measurement, 5×1011 events were accumulated over a measurement period of 60 days, which resulted in low statistical uncertainties for the coincident counting between detector pairs (less than 1%). Through simplifying assumptions that neglected the background corrections and efficiency normalisations for each of the 2γ and 4γ decays, a first order approximation of BR4γ was determined as the ratio between measured 4γ events (N4γ) and measured 2γ events (N2γ), such that BR4γ ∼ N4γ N2γ = 4.8 (19) × 10−7. This measured value of BR4γ differs from previous measurements and accepted literature values by a factor of 3.
format Thesis
id oai:open.uct.ac.za:11427/36466
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:46:32.808Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2022
publishDateRange 2022
publishDateSort 2022
publisher Department of Physics
publisherStr Department of Physics
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/36466 Multi-photon decay mode spectroscopy of positronium Johnson, Storm Leadbeater, Thomas Jones, Pete Physics An approximation for the branching ratio of the four-photon decay of parapositronium (BR4γ) was measured using a multi-gamma-ray spectrometer. For the first time in such measurements, the spectrometer consisted of an array of eight identical LaBr3:Ce scintillator detectors, each of which combines good energy resolutions (5% and 10% at 511 keV for the signals from the eighth dynode and anode of the photomultiplier tube, respectively) with an excellent timing resolution (∼ 300 ps). These energy resolutions were minimised through an optimal selection of the digital signal processing parameter settings. The detectors were situated in a planar geometry, where the source-to-detector distance of the detector system was selected such that the effect of peak pulse pile-up was minimised (to less than 3%), while maximising the full-energy peak detection efficiency at 511 keV (to 3%). For this work, locally-produced 22Na radioactive sources were used as positron emitters, which enabled the formation of positronium and subsequent gamma decays. Energy calibration measurements were performed using a 152Eu source, where the prominent energy peaks of (121.8, 244.7, 344.3, 778.9, 964.1, 1408.0) keV were used for calibration. For the BR4γ measurement, 5×1011 events were accumulated over a measurement period of 60 days, which resulted in low statistical uncertainties for the coincident counting between detector pairs (less than 1%). Through simplifying assumptions that neglected the background corrections and efficiency normalisations for each of the 2γ and 4γ decays, a first order approximation of BR4γ was determined as the ratio between measured 4γ events (N4γ) and measured 2γ events (N2γ), such that BR4γ ∼ N4γ N2γ = 4.8 (19) × 10−7. This measured value of BR4γ differs from previous measurements and accepted literature values by a factor of 3. 2022-06-10T10:11:07Z 2022-06-10T10:11:07Z 2022 2022-06-10T10:10:13Z Master Thesis Masters MSc http://hdl.handle.net/11427/36466 eng application/pdf Department of Physics Faculty of Science
spellingShingle Physics
Johnson, Storm
Multi-photon decay mode spectroscopy of positronium
thesis_degree_str Master's
title Multi-photon decay mode spectroscopy of positronium
title_full Multi-photon decay mode spectroscopy of positronium
title_fullStr Multi-photon decay mode spectroscopy of positronium
title_full_unstemmed Multi-photon decay mode spectroscopy of positronium
title_short Multi-photon decay mode spectroscopy of positronium
title_sort multi photon decay mode spectroscopy of positronium
topic Physics
url http://hdl.handle.net/11427/36466
work_keys_str_mv AT johnsonstorm multiphotondecaymodespectroscopyofpositronium