Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Polymeric Transcatheter Heart Valves

Rheumatic heart disease (RHD) is one of the main causes of heart disease in the emerging world. Once the disease has become symptomatic valve repair or replacement is the only treatment currently available. Commercial bioprosthetic valves (surgical and transcatheter) suffer from calcification and de...

Full description

Saved in:
Bibliographic Details
Main Author: Coetzee, Johan
Other Authors: Bezuidenhout, Deon
Format: Thesis
Language:English
Published: Division of General Surgery 2022
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613385127886848
access_status_str Open Access
author Coetzee, Johan
author2 Bezuidenhout, Deon
author_browse Bezuidenhout, Deon
Coetzee, Johan
author_facet Bezuidenhout, Deon
Coetzee, Johan
author_sort Coetzee, Johan
collection Thesis
description Rheumatic heart disease (RHD) is one of the main causes of heart disease in the emerging world. Once the disease has become symptomatic valve repair or replacement is the only treatment currently available. Commercial bioprosthetic valves (surgical and transcatheter) suffer from calcification and decreased durability, especially when implanted into younger patients, while mechanical surgical valves require life-long anticoagulation. Polymeric transcatheter aortic valve insertion (TAVI) is proposed as a solution to provide long-term durability without the need for anticoagulation. A manufacturing method involving the spray coating of polyurethane solutions onto valve moulds, pre-coating a TAVI stent with a polyurethane of higher durometer, and subsequently spraying the combination of the stent and the mould to form integral attachments of the leaflets, is described. Valves were tested for leaflet thickness distribution, hydrodynamic function and accelerated durability, and subsequently implanted in an acute ovine TAVI model as proof of concept. Effective Orifice Area (EOA) >1.7 cm2, regurgitation < 10% and transvalvular pressure gradient < 10 mmHg were achieved. Leaflet thickness correlated indirectly with the EOA and directly with transvalvular pressure gradient, but not regurgitation. After iterative improvements in the manufacturing process, valves with average thicknesses ranging from 140 to 160 μm showed highest durability (>150 million, and up to 600 million cycles). Surface roughness was reduced by applying a final pure solvent coat. Implanted valves showed good function, with no apparent central or paravalvular regurgitation, perfusion of coronaries, and EOA greater than1.6 cm2. In conclusion, a polymeric TAVI valve made by a new manufacturing method showed durability up to 15 years equivalent in vitro, and good hydrodynamic function in vitro and in vivo. The devices hold many potential advantages in terms of automation and cost of manufacturing, as well as function and longevity.
format Thesis
id oai:open.uct.ac.za:11427/36761
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:35:18.373Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2022
publishDateRange 2022
publishDateSort 2022
publisher Division of General Surgery
publisherStr Division of General Surgery
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/36761 Polymeric Transcatheter Heart Valves Coetzee, Johan Bezuidenhout, Deon de Villiers, Jandre Biomaterials Rheumatic heart disease (RHD) is one of the main causes of heart disease in the emerging world. Once the disease has become symptomatic valve repair or replacement is the only treatment currently available. Commercial bioprosthetic valves (surgical and transcatheter) suffer from calcification and decreased durability, especially when implanted into younger patients, while mechanical surgical valves require life-long anticoagulation. Polymeric transcatheter aortic valve insertion (TAVI) is proposed as a solution to provide long-term durability without the need for anticoagulation. A manufacturing method involving the spray coating of polyurethane solutions onto valve moulds, pre-coating a TAVI stent with a polyurethane of higher durometer, and subsequently spraying the combination of the stent and the mould to form integral attachments of the leaflets, is described. Valves were tested for leaflet thickness distribution, hydrodynamic function and accelerated durability, and subsequently implanted in an acute ovine TAVI model as proof of concept. Effective Orifice Area (EOA) >1.7 cm2, regurgitation < 10% and transvalvular pressure gradient < 10 mmHg were achieved. Leaflet thickness correlated indirectly with the EOA and directly with transvalvular pressure gradient, but not regurgitation. After iterative improvements in the manufacturing process, valves with average thicknesses ranging from 140 to 160 μm showed highest durability (>150 million, and up to 600 million cycles). Surface roughness was reduced by applying a final pure solvent coat. Implanted valves showed good function, with no apparent central or paravalvular regurgitation, perfusion of coronaries, and EOA greater than1.6 cm2. In conclusion, a polymeric TAVI valve made by a new manufacturing method showed durability up to 15 years equivalent in vitro, and good hydrodynamic function in vitro and in vivo. The devices hold many potential advantages in terms of automation and cost of manufacturing, as well as function and longevity. 2022-08-30T08:37:08Z 2022-08-30T08:37:08Z 2019 2022-07-20T09:36:23Z Master Thesis Masters MSc http://hdl.handle.net/11427/36761 eng application/pdf Division of General Surgery Faculty of Health Sciences
spellingShingle Biomaterials
Coetzee, Johan
Polymeric Transcatheter Heart Valves
thesis_degree_str Master's
title Polymeric Transcatheter Heart Valves
title_full Polymeric Transcatheter Heart Valves
title_fullStr Polymeric Transcatheter Heart Valves
title_full_unstemmed Polymeric Transcatheter Heart Valves
title_short Polymeric Transcatheter Heart Valves
title_sort polymeric transcatheter heart valves
topic Biomaterials
url http://hdl.handle.net/11427/36761
work_keys_str_mv AT coetzeejohan polymerictranscatheterheartvalves