Calibration of orifice plates with special emphasis on edge sharpness and eccentricity

A general review of the literature pertaining to flov1 measurement with orifice plates is presented. Special emphasis is laid on the factors influencing the coefficient of discharge Of orifice plates and. on the difference between the various engineering standards. Particular consideration is given...

Full description

Saved in:
Bibliographic Details
Main Author: Lebi, Juliu
Other Authors: Dutkiewicz, R K
Format: Thesis
Language:English
Published: Department of Mechanical Engineering 2023
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613206283812864
access_status_str Open Access
author Lebi, Juliu
author2 Dutkiewicz, R K
author_browse Dutkiewicz, R K
Lebi, Juliu
author_facet Dutkiewicz, R K
Lebi, Juliu
author_sort Lebi, Juliu
collection Thesis
description A general review of the literature pertaining to flov1 measurement with orifice plates is presented. Special emphasis is laid on the factors influencing the coefficient of discharge Of orifice plates and. on the difference between the various engineering standards. Particular consideration is given to the effect on the discharge coefficient of rounding the upstream edge of the orifice plate and of changes in plate eccentricity. Various methods to calibrate orifice plates and to measure the edge roundness of orifice plates are discussed. Orifice plates with area ratios ranging from 0,1.to 0,55 were tested in order to evaluate variations in the coefficient of discharge with changes in: a) the upstream edge radius; b) the plate concentricity ty. The calibration tests were conducted with apparatus based on a system of weighing the working fluid which accumulates in a tank over an accurately determined time interval. In order to measure the upstream edge radius of an orifice plate, a lead foil holder was designed. Using the holder, accurate imprints of the edge profile were obtained in the lead foil. The apparatus used and the method of calibration is described in detail. Attention is drawn to the precautions required for accurate calibration. The method of calibration used was complicated by fluctuations in the differential pressure. It was found that the mean of twelve random pressure differential readings at a specific flow rate: did not vary by more than .f ·- o, 05 mm of mercury. Increasing the number of pressures
format Thesis
id oai:open.uct.ac.za:11427/38908
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:32:27.580Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2023
publishDateRange 2023
publishDateSort 2023
publisher Department of Mechanical Engineering
publisherStr Department of Mechanical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/38908 Calibration of orifice plates with special emphasis on edge sharpness and eccentricity Lebi, Juliu Dutkiewicz, R K Engineering - Mechanical Engineering A general review of the literature pertaining to flov1 measurement with orifice plates is presented. Special emphasis is laid on the factors influencing the coefficient of discharge Of orifice plates and. on the difference between the various engineering standards. Particular consideration is given to the effect on the discharge coefficient of rounding the upstream edge of the orifice plate and of changes in plate eccentricity. Various methods to calibrate orifice plates and to measure the edge roundness of orifice plates are discussed. Orifice plates with area ratios ranging from 0,1.to 0,55 were tested in order to evaluate variations in the coefficient of discharge with changes in: a) the upstream edge radius; b) the plate concentricity ty. The calibration tests were conducted with apparatus based on a system of weighing the working fluid which accumulates in a tank over an accurately determined time interval. In order to measure the upstream edge radius of an orifice plate, a lead foil holder was designed. Using the holder, accurate imprints of the edge profile were obtained in the lead foil. The apparatus used and the method of calibration is described in detail. Attention is drawn to the precautions required for accurate calibration. The method of calibration used was complicated by fluctuations in the differential pressure. It was found that the mean of twelve random pressure differential readings at a specific flow rate: did not vary by more than .f ·- o, 05 mm of mercury. Increasing the number of pressures 2023-09-27T13:57:19Z 2023-09-27T13:57:19Z 1979 2023-09-27T13:25:24Z Master Thesis Masters MSc http://hdl.handle.net/11427/38908 eng application/pdf Department of Mechanical Engineering Faculty of Engineering and the Built Environment
spellingShingle Engineering - Mechanical Engineering
Lebi, Juliu
Calibration of orifice plates with special emphasis on edge sharpness and eccentricity
thesis_degree_str Master's
title Calibration of orifice plates with special emphasis on edge sharpness and eccentricity
title_full Calibration of orifice plates with special emphasis on edge sharpness and eccentricity
title_fullStr Calibration of orifice plates with special emphasis on edge sharpness and eccentricity
title_full_unstemmed Calibration of orifice plates with special emphasis on edge sharpness and eccentricity
title_short Calibration of orifice plates with special emphasis on edge sharpness and eccentricity
title_sort calibration of orifice plates with special emphasis on edge sharpness and eccentricity
topic Engineering - Mechanical Engineering
url http://hdl.handle.net/11427/38908
work_keys_str_mv AT lebijuliu calibrationoforificeplateswithspecialemphasisonedgesharpnessandeccentricity