Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Developing a minimal-input one-dimensional methodology for modelling axial compressors using a diffuser analogy

Despite notable advances in Computational Fluid Dynamics as a tool for gas turbine design, the analysis and performance prediction of turbomachinery still benefits greatly from the use of one- dimensional mean-line modelling, as it can provide results of acceptable accuracy while requiring fewer geo...

Full description

Saved in:
Bibliographic Details
Main Author: Barlin, Daniel
Other Authors: Fuls, Wim
Format: Thesis
Language:English
Eg
Published: Department of Mechanical Engineering 2024
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867611354873987072
access_status_str Open Access
author Barlin, Daniel
author2 Fuls, Wim
author_browse Barlin, Daniel
Fuls, Wim
author_facet Fuls, Wim
Barlin, Daniel
author_sort Barlin, Daniel
collection Thesis
description Despite notable advances in Computational Fluid Dynamics as a tool for gas turbine design, the analysis and performance prediction of turbomachinery still benefits greatly from the use of one- dimensional mean-line modelling, as it can provide results of acceptable accuracy while requiring fewer geometric inputs, as well as comparatively lower computational expenses. However, even mean-line codes are often limited by the amount of geometric and operational data available, often withheld by Original Equipment Manufacturers for proprietary reasons. As a result, a large number of tuning factors are often employed in mean-line simulations to achieve more accurate results. This report describes the development of a one-dimensional modelling methodology which requires minimal geometric inputs and tuning factors for predicting the performance of a transonic axial compressor stage, for use in a gas turbine. The minimal input model is achieved through development of a diffuser analogy, whereby the stage's rotor and stator rows are modelled as simple diffusers with passage flow areas approximately equal to those in the compressor stage. A design point calibration operation is first performed to estimate all diffuser flow path areas using a set of industry knowledge-based assumptions, and blade angles are determined using widely adopted correlations from open literature. The estimated geometries are then used as inputs for an off-design model built in Flownex SE. Using correlations of total pressure loss from the open literature, the Flownex model is then able to predict the stage's performance over a range of off-design operating conditions. The model was validated against a well-documented axial compressor stage from NASA through four successive models. First, Flownex's built-in Designer function was used to determine the rotor losses that would result in good agreement with experimental data of stage total pressure ratio. The second model adopted a simple total pressure loss correlation from the literature. The third model employed a single calibration factor for adjusting flow path areas, in order to obtain better agreement with the experimental data. Further definition of the area calibration factor was achieved by applying the third model to three other NASA compressor stages. Finally, correlations determined from this exercise were evaluated. The methodology presented an efficient means of predicting compressor stage performance with acceptable accuracy, while requiring minimal geometric inputs and only a single calibration factor, thus allowing gas turbine operators and analysts to gain greater insight into the compressor's off-design behaviour with the limited geometric and operational data available to them.
format Thesis
id oai:open.uct.ac.za:11427/39225
institution University of Cape Town (South Africa)
language English
Eg
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2024
publishDateRange 2024
publishDateSort 2024
publisher Department of Mechanical Engineering
publisherStr Department of Mechanical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/39225 Developing a minimal-input one-dimensional methodology for modelling axial compressors using a diffuser analogy Barlin, Daniel Fuls, Wim Engineering Despite notable advances in Computational Fluid Dynamics as a tool for gas turbine design, the analysis and performance prediction of turbomachinery still benefits greatly from the use of one- dimensional mean-line modelling, as it can provide results of acceptable accuracy while requiring fewer geometric inputs, as well as comparatively lower computational expenses. However, even mean-line codes are often limited by the amount of geometric and operational data available, often withheld by Original Equipment Manufacturers for proprietary reasons. As a result, a large number of tuning factors are often employed in mean-line simulations to achieve more accurate results. This report describes the development of a one-dimensional modelling methodology which requires minimal geometric inputs and tuning factors for predicting the performance of a transonic axial compressor stage, for use in a gas turbine. The minimal input model is achieved through development of a diffuser analogy, whereby the stage's rotor and stator rows are modelled as simple diffusers with passage flow areas approximately equal to those in the compressor stage. A design point calibration operation is first performed to estimate all diffuser flow path areas using a set of industry knowledge-based assumptions, and blade angles are determined using widely adopted correlations from open literature. The estimated geometries are then used as inputs for an off-design model built in Flownex SE. Using correlations of total pressure loss from the open literature, the Flownex model is then able to predict the stage's performance over a range of off-design operating conditions. The model was validated against a well-documented axial compressor stage from NASA through four successive models. First, Flownex's built-in Designer function was used to determine the rotor losses that would result in good agreement with experimental data of stage total pressure ratio. The second model adopted a simple total pressure loss correlation from the literature. The third model employed a single calibration factor for adjusting flow path areas, in order to obtain better agreement with the experimental data. Further definition of the area calibration factor was achieved by applying the third model to three other NASA compressor stages. Finally, correlations determined from this exercise were evaluated. The methodology presented an efficient means of predicting compressor stage performance with acceptable accuracy, while requiring minimal geometric inputs and only a single calibration factor, thus allowing gas turbine operators and analysts to gain greater insight into the compressor's off-design behaviour with the limited geometric and operational data available to them. 2024-03-11T12:07:18Z 2024-03-11T12:07:18Z 2023 2024-03-11T11:55:30Z Thesis / Dissertation Masters MSc http://hdl.handle.net/11427/39225 en Eg application/pdf Department of Mechanical Engineering Faculty of Engineering and the Built Environment
spellingShingle Engineering
Barlin, Daniel
Developing a minimal-input one-dimensional methodology for modelling axial compressors using a diffuser analogy
thesis_degree_str Master's
title Developing a minimal-input one-dimensional methodology for modelling axial compressors using a diffuser analogy
title_full Developing a minimal-input one-dimensional methodology for modelling axial compressors using a diffuser analogy
title_fullStr Developing a minimal-input one-dimensional methodology for modelling axial compressors using a diffuser analogy
title_full_unstemmed Developing a minimal-input one-dimensional methodology for modelling axial compressors using a diffuser analogy
title_short Developing a minimal-input one-dimensional methodology for modelling axial compressors using a diffuser analogy
title_sort developing a minimal input one dimensional methodology for modelling axial compressors using a diffuser analogy
topic Engineering
url http://hdl.handle.net/11427/39225
work_keys_str_mv AT barlindaniel developingaminimalinputonedimensionalmethodologyformodellingaxialcompressorsusingadiffuseranalogy