Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon

Background External beam radiotherapy (EBRT) is an important part of the treatment for prostate cancer. To account for organ motion and set-up error, margins are used in radiotherapy planning. These are essential for the delivery of safe and effective treatment. Aim and Setting To measure prostate m...

Full description

Saved in:
Bibliographic Details
Main Author: Algar, Marion
Other Authors: Punt, Lydia
Format: Thesis
Language:English
Published: Division of Radiology 2024
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613243015430144
access_status_str Open Access
author Algar, Marion
author2 Punt, Lydia
author_browse Algar, Marion
Punt, Lydia
author_facet Punt, Lydia
Algar, Marion
author_sort Algar, Marion
collection Thesis
description Background External beam radiotherapy (EBRT) is an important part of the treatment for prostate cancer. To account for organ motion and set-up error, margins are used in radiotherapy planning. These are essential for the delivery of safe and effective treatment. Aim and Setting To measure prostate motion during the course of EBRT on the HalcyonTM at Groote Schuur Hospital. Using published margin recipes, the minimum clinical target volume (CTV)-planning target volume (PTV) expansion margin was calculated. Patients and Methods Prostate motion was evaluated by comparing prostate position on the planning CT to cone-beam CT (CBCT) scans. Prostate position error in the medio-lateral (ML), antero-posterior (AP) and superoinferior (SI) directions was measured for each CBCT. The systematic (Σ) and random (σ) error of prostate motion was calculated. The minimum CTV-PTV margin was determined. Results The mean position error of the prostate was -0.04mm (95% CI -0.14, 0.10), -0.30mm (95% CI -0.70, 0.15) and -0.40mm (95% CI -0.89, 0.00) in the ML, AP and SI directions, respectively. Using Van Herk's margin formula (2.5Σ +0.7σ), the following minimum CTV-PTV margins for the ML, AP and SI directions were calculated: 1.9mm, 6.9mm and 7.8mm, respectively. Using Stroom's margin formula (2Σ +0.7σ), the following minimum CTV-PTV margins for the ML, AP and SI directions were calculated: 1.6mm, 5.8mm and 6.6mm, respectively. Conclusion Based on prostate motion, our institution's current margins are sufficient. However, further studies are necessary to measure other factors that influence the CTV-PTV margin before considering reducing this margin.
format Thesis
id oai:open.uct.ac.za:11427/39261
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:33:01.081Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2024
publishDateRange 2024
publishDateSort 2024
publisher Division of Radiology
publisherStr Division of Radiology
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/39261 Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon Algar, Marion Punt, Lydia Radiation Oncology Background External beam radiotherapy (EBRT) is an important part of the treatment for prostate cancer. To account for organ motion and set-up error, margins are used in radiotherapy planning. These are essential for the delivery of safe and effective treatment. Aim and Setting To measure prostate motion during the course of EBRT on the HalcyonTM at Groote Schuur Hospital. Using published margin recipes, the minimum clinical target volume (CTV)-planning target volume (PTV) expansion margin was calculated. Patients and Methods Prostate motion was evaluated by comparing prostate position on the planning CT to cone-beam CT (CBCT) scans. Prostate position error in the medio-lateral (ML), antero-posterior (AP) and superoinferior (SI) directions was measured for each CBCT. The systematic (Σ) and random (σ) error of prostate motion was calculated. The minimum CTV-PTV margin was determined. Results The mean position error of the prostate was -0.04mm (95% CI -0.14, 0.10), -0.30mm (95% CI -0.70, 0.15) and -0.40mm (95% CI -0.89, 0.00) in the ML, AP and SI directions, respectively. Using Van Herk's margin formula (2.5Σ +0.7σ), the following minimum CTV-PTV margins for the ML, AP and SI directions were calculated: 1.9mm, 6.9mm and 7.8mm, respectively. Using Stroom's margin formula (2Σ +0.7σ), the following minimum CTV-PTV margins for the ML, AP and SI directions were calculated: 1.6mm, 5.8mm and 6.6mm, respectively. Conclusion Based on prostate motion, our institution's current margins are sufficient. However, further studies are necessary to measure other factors that influence the CTV-PTV margin before considering reducing this margin. 2024-03-28T09:31:11Z 2024-03-28T09:31:11Z 2023 2024-03-28T08:28:58Z Thesis / Dissertation Masters MMed http://hdl.handle.net/11427/39261 eng application/pdf Division of Radiology Faculty of Health Sciences
spellingShingle Radiation Oncology
Algar, Marion
Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon
thesis_degree_str Master's
title Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon
title_full Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon
title_fullStr Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon
title_full_unstemmed Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon
title_short Evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on Halcyon
title_sort evaluation of target motion and determination optional treatment margins for prostate cancer treated with external beam radiotherapy on halcyon
topic Radiation Oncology
url http://hdl.handle.net/11427/39261
work_keys_str_mv AT algarmarion evaluationoftargetmotionanddeterminationoptionaltreatmentmarginsforprostatecancertreatedwithexternalbeamradiotherapyonhalcyon