Testing for relationship between diagnostic tests and DC BDV of in-serviced aged stator bars of a hydro generator

The effective management of assets currently presents a challenge to utilities. A cognisance and understanding of the actual condition of these assets will enable utilities to implement mitigation strategies and use these assets for the full duration of their lifespan. One of these assets could be h...

Full description

Saved in:
Bibliographic Details
Main Author: Bruintjies, Mark Anthony
Other Authors: Gaunt, Trevor
Format: Thesis
Language:English
Published: Department of Electrical Engineering 2025
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613339931115520
access_status_str Open Access
author Bruintjies, Mark Anthony
author2 Gaunt, Trevor
author_browse Bruintjies, Mark Anthony
Gaunt, Trevor
author_facet Gaunt, Trevor
Bruintjies, Mark Anthony
author_sort Bruintjies, Mark Anthony
collection Thesis
description The effective management of assets currently presents a challenge to utilities. A cognisance and understanding of the actual condition of these assets will enable utilities to implement mitigation strategies and use these assets for the full duration of their lifespan. One of these assets could be hydro generators with the stator bars constituting one of the failing components. Integral to the satisfactory operation of a high voltage (HV) electrical rotating plant is the integrity of the electrical high voltage insulation of both the rotor and stator. During operation, high voltage generator components (for example stator bars), are continuously and simultaneously subjected to electrical, thermal, mechanical and ambient (environment) stresses. Subsequently, the complex interactions of these stresses degrade and deteriorate the insulation material gradually, resulting in a reduction of valuable operative life, potential forced outages and costly emergency repairs. Because both expected and unexpected stator bar in-service failures may lead to costly repairs, rotating machine users implement condition monitoring (CM), diagnostic tests and condition-based maintenance in order to mitigate risk. The contribution was executed in the form of removing aged stator bars from a generator and subjecting the bars to various diagnostic and direct current (DC) HV tests, testing for correlation. The diagnostic tests included insulation resistance (IR), polarization index (PI), partial discharge (PD), tan delta (TD) and Tennessee Valley Authority (TVA) tests. The HV breakdown tests included very low frequency (VLF) and DC tests. Despite using this wider range of tests than has been used before, the test results still confirm earlier reports that there are no clear correlations between the different diagnostic tests. There is also no clear relationship between the condition monitoring test results and physical breakdown of the insulation in the high voltage tests. Hence, it was concluded that these diagnostic tests on their own could not predict incipient insulation failure and that currently the most value derived from these tests would be to use the results as trending parameters rather than absolute values to predict insulation failure.
format Thesis
id oai:open.uct.ac.za:11427/40805
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:34:33.896Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2025
publishDateRange 2025
publishDateSort 2025
publisher Department of Electrical Engineering
publisherStr Department of Electrical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/40805 Testing for relationship between diagnostic tests and DC BDV of in-serviced aged stator bars of a hydro generator Bruintjies, Mark Anthony Gaunt, Trevor Barendse, Paul electrical engineering The effective management of assets currently presents a challenge to utilities. A cognisance and understanding of the actual condition of these assets will enable utilities to implement mitigation strategies and use these assets for the full duration of their lifespan. One of these assets could be hydro generators with the stator bars constituting one of the failing components. Integral to the satisfactory operation of a high voltage (HV) electrical rotating plant is the integrity of the electrical high voltage insulation of both the rotor and stator. During operation, high voltage generator components (for example stator bars), are continuously and simultaneously subjected to electrical, thermal, mechanical and ambient (environment) stresses. Subsequently, the complex interactions of these stresses degrade and deteriorate the insulation material gradually, resulting in a reduction of valuable operative life, potential forced outages and costly emergency repairs. Because both expected and unexpected stator bar in-service failures may lead to costly repairs, rotating machine users implement condition monitoring (CM), diagnostic tests and condition-based maintenance in order to mitigate risk. The contribution was executed in the form of removing aged stator bars from a generator and subjecting the bars to various diagnostic and direct current (DC) HV tests, testing for correlation. The diagnostic tests included insulation resistance (IR), polarization index (PI), partial discharge (PD), tan delta (TD) and Tennessee Valley Authority (TVA) tests. The HV breakdown tests included very low frequency (VLF) and DC tests. Despite using this wider range of tests than has been used before, the test results still confirm earlier reports that there are no clear correlations between the different diagnostic tests. There is also no clear relationship between the condition monitoring test results and physical breakdown of the insulation in the high voltage tests. Hence, it was concluded that these diagnostic tests on their own could not predict incipient insulation failure and that currently the most value derived from these tests would be to use the results as trending parameters rather than absolute values to predict insulation failure. 2025-01-15T11:38:46Z 2025-01-15T11:38:46Z 2024 2025-01-15T11:28:41Z Thesis / Dissertation Doctoral PhD http://hdl.handle.net/11427/40805 eng application/pdf Department of Electrical Engineering Faculty of Engineering and the Built Environment University of Cape Town
spellingShingle electrical engineering
Bruintjies, Mark Anthony
Testing for relationship between diagnostic tests and DC BDV of in-serviced aged stator bars of a hydro generator
thesis_degree_str Doctoral
title Testing for relationship between diagnostic tests and DC BDV of in-serviced aged stator bars of a hydro generator
title_full Testing for relationship between diagnostic tests and DC BDV of in-serviced aged stator bars of a hydro generator
title_fullStr Testing for relationship between diagnostic tests and DC BDV of in-serviced aged stator bars of a hydro generator
title_full_unstemmed Testing for relationship between diagnostic tests and DC BDV of in-serviced aged stator bars of a hydro generator
title_short Testing for relationship between diagnostic tests and DC BDV of in-serviced aged stator bars of a hydro generator
title_sort testing for relationship between diagnostic tests and dc bdv of in serviced aged stator bars of a hydro generator
topic electrical engineering
url http://hdl.handle.net/11427/40805
work_keys_str_mv AT bruintjiesmarkanthony testingforrelationshipbetweendiagnostictestsanddcbdvofinservicedagedstatorbarsofahydrogenerator