Full Text Available
Note: Clicking the button above will open the full text document at the original institutional repository in a new window.
Includes bibliographical references (leaves 78-80).
| Main Author: | |
|---|---|
| Other Authors: | |
| Format: | Thesis |
| Language: | English |
| Published: |
Department of Electrical Engineering
2014
|
| Subjects: | |
| Tags: |
No Tags, Be the first to tag this record!
|
| _version_ | 1867613616691216384 |
|---|---|
| access_status_str | Open Access |
| author | Sattar, Fayaaz Ali |
| author2 | Wilkinson, Andrew John |
| author_browse | Sattar, Fayaaz Ali Wilkinson, Andrew John |
| author_facet | Wilkinson, Andrew John Sattar, Fayaaz Ali |
| author_sort | Sattar, Fayaaz Ali |
| collection | Thesis |
| description | Includes bibliographical references (leaves 78-80). |
| format | Thesis |
| id | oai:open.uct.ac.za:11427/5108 |
| institution | University of Cape Town (South Africa) |
| language | eng |
| last_indexed | 2026-06-10T12:38:59.209Z |
| license_str | Not specified — see source repository |
| provenance_str_mv | Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository |
| publishDate | 2014 |
| publishDateRange | 2014 |
| publishDateSort | 2014 |
| publisher | Department of Electrical Engineering |
| publisherStr | Department of Electrical Engineering |
| record_format | dspace |
| source_str | UCTD — University of Cape Town Open Access Repository |
| spelling | oai:open.uct.ac.za:11427/5108 Rot detection in wooden poles using electrical impedance tomography Sattar, Fayaaz Ali Wilkinson, Andrew John Electrical Engineering Includes bibliographical references (leaves 78-80). The proposal for this dissertation was to develop a nondestructive method of testing wooden utility poles for rot and termite damage. The nondestructive method that was chosen for this project was that of electrical impedance tomography in which an image of the permittivity in a cross section would be created from impedance measurements made between electrodes attached to the boundary of the pole. 2014-07-31T10:52:50Z 2014-07-31T10:52:50Z 2006 Master Thesis Masters MSc http://hdl.handle.net/11427/5108 eng application/pdf Department of Electrical Engineering Faculty of Engineering and the Built Environment University of Cape Town |
| spellingShingle | Electrical Engineering Sattar, Fayaaz Ali Rot detection in wooden poles using electrical impedance tomography |
| thesis_degree_str | Master's |
| title | Rot detection in wooden poles using electrical impedance tomography |
| title_full | Rot detection in wooden poles using electrical impedance tomography |
| title_fullStr | Rot detection in wooden poles using electrical impedance tomography |
| title_full_unstemmed | Rot detection in wooden poles using electrical impedance tomography |
| title_short | Rot detection in wooden poles using electrical impedance tomography |
| title_sort | rot detection in wooden poles using electrical impedance tomography |
| topic | Electrical Engineering |
| url | http://hdl.handle.net/11427/5108 |
| work_keys_str_mv | AT sattarfayaazali rotdetectioninwoodenpolesusingelectricalimpedancetomography |