The design and testing of a constrained proximal humeral total shoulder replacement (TSR)

Includes bibliographical references (p.71-78).

Saved in:
Bibliographic Details
Main Author: Wessels, Gregory D
Format: Thesis
Language:English
Published: Department of Mechanical Engineering 2014
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613153967210496
access_status_str Open Access
author Wessels, Gregory D
author_browse Wessels, Gregory D
author_facet Wessels, Gregory D
author_sort Wessels, Gregory D
collection Thesis
description Includes bibliographical references (p.71-78).
format Thesis
id oai:open.uct.ac.za:11427/5453
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:31:35.974Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2014
publishDateRange 2014
publishDateSort 2014
publisher Department of Mechanical Engineering
publisherStr Department of Mechanical Engineering
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/5453 The design and testing of a constrained proximal humeral total shoulder replacement (TSR) Wessels, Gregory D Mechanical Engineering Includes bibliographical references (p.71-78). Orthopedic oncology provides for a challenging field in prosthetic design, especially in proximal humeral sarcoma cases. In these cases a large volume of bone an muscle is removed as a result of the sarcoma. This leaves insufficient musculature to stabilize an un-constrained prosthesis. This report deals with the design and testing of constrained total shoulder replacements, as their inherent built-in stability compensates for lost musculature stability. The weakest area of any shoulder replacement is the fixation of the glenoid component to the scapula. The design of an innovative glenoidal attachment system was the main focus of the project. 2014-07-31T11:17:53Z 2014-07-31T11:17:53Z 2005 Master Thesis Masters MSc http://hdl.handle.net/11427/5453 eng application/pdf Department of Mechanical Engineering Faculty of Engineering and the Built Environment University of Cape Town
spellingShingle Mechanical Engineering
Wessels, Gregory D
The design and testing of a constrained proximal humeral total shoulder replacement (TSR)
thesis_degree_str Master's
title The design and testing of a constrained proximal humeral total shoulder replacement (TSR)
title_full The design and testing of a constrained proximal humeral total shoulder replacement (TSR)
title_fullStr The design and testing of a constrained proximal humeral total shoulder replacement (TSR)
title_full_unstemmed The design and testing of a constrained proximal humeral total shoulder replacement (TSR)
title_short The design and testing of a constrained proximal humeral total shoulder replacement (TSR)
title_sort design and testing of a constrained proximal humeral total shoulder replacement tsr
topic Mechanical Engineering
url http://hdl.handle.net/11427/5453
work_keys_str_mv AT wesselsgregoryd thedesignandtestingofaconstrainedproximalhumeraltotalshoulderreplacementtsr
AT wesselsgregoryd designandtestingofaconstrainedproximalhumeraltotalshoulderreplacementtsr