Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment

Includes abstract.

Saved in:
Bibliographic Details
Main Author: Chimhundu, Chipo
Other Authors: Douglas, Tania S
Format: Thesis
Language:English
Published: Department of Human Biology 2014
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613213974069248
access_status_str Open Access
author Chimhundu, Chipo
author2 Douglas, Tania S
author_browse Chimhundu, Chipo
Douglas, Tania S
author_facet Douglas, Tania S
Chimhundu, Chipo
author_sort Chimhundu, Chipo
collection Thesis
description Includes abstract.
format Thesis
id oai:open.uct.ac.za:11427/6013
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:32:34.479Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2014
publishDateRange 2014
publishDateSort 2014
publisher Department of Human Biology
publisherStr Department of Human Biology
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/6013 Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment Chimhundu, Chipo Douglas, Tania S Includes abstract. Includes bibliographical references. Clinicians often take measurements between anatomical landmarks on X-ray radiographs for diagnosis and treatment planning, for example in orthopaedics and orthodontics. X-ray images, however, overlap three-dimensional internal structures onto a two-dimensional plane during image formation. Depth information is therefore lost and measurements do not truly reflect spatial relationships. The main aim of this study was to develop an inter-landmark measurement tool for the Lodox Statscan digital radiography system. X-ray stereophotogrammetry was applied to Statscan images to enable three-dimensional point localization for inter-landmark measurement using two-dimensional radiographs. This technique requires images of the anatomical region of interest to be acquired from different perspectives as well as a suitable calibration tool to map image coordinates to real world coordinates. The Statscan is suited to the technique because it is capable of axial rotations for multiview imaging. Three-dimensional coordinate reconstruction and inter-landmark measurements were taken using a planar object and a dry pelvis specimen in order to assess the intra-observer measurement accuracy, reliability and precision. The system yielded average (X, Y, Z) coordinate reconstruction accuracy of (0.08 0.12 0.34) mm and resultant coordinate reconstruction accuracy within 0.4mm (range 0.3mm – 0.6mm). Inter-landmark measurements within 2mm for lengths and 1.80 for angles were obtained, with average accuracies of 0.4mm (range 0.0mm – 2.0 mm) and 0.30 (range 0.0 – 1.8)0 respectively. The results also showed excellent overall precision of (0.5mm, 0.10) and were highly reliable when all landmarks were completely visible in both images. Femoral neck anteversion measurement on Statscan images was also explored using 30 dry right adult femurs. This was done in order to assess the feasibility of the algorithm for a clinical application. For this investigation, four methods were tested to determine the optimal landmarks for measurement and the measurement process involved calculation of virtual landmarks. The method that yielded the best results produced all measurements within 10 of reference values and the measurements were highly reliable with very good precision within 0.10. The average accuracy was within 0.40 (range 0.10 –0.80).In conclusion, X-ray stereophotogrammetry enables accurate, reliable and precise inter-landmark measurements for the Lodox Statscan X-ray imaging system. The machine may therefore be used as an inter-landmark measurement tool for routine clinical applications. 2014-08-05T12:30:28Z 2014-08-05T12:30:28Z 2013 Master Thesis Masters MSc http://hdl.handle.net/11427/6013 eng application/pdf Department of Human Biology Faculty of Health Sciences University of Cape Town
spellingShingle Chimhundu, Chipo
Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment
thesis_degree_str Master's
title Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment
title_full Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment
title_fullStr Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment
title_full_unstemmed Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment
title_short Interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment
title_sort interlandmark measurements from lodox statscan images with application to femoral neck anteversion assessment
url http://hdl.handle.net/11427/6013
work_keys_str_mv AT chimhunduchipo interlandmarkmeasurementsfromlodoxstatscanimageswithapplicationtofemoralneckanteversionassessment