Full Text Available
Note: Clicking the button above will open the full text document at the original institutional repository in a new window.
Includes bibliographical references.
| Main Author: | |
|---|---|
| Other Authors: | |
| Format: | Thesis |
| Language: | English |
| Published: |
Department of Mechanical Engineering
2014
|
| Tags: |
No Tags, Be the first to tag this record!
|
| _version_ | 1867614190297939968 |
|---|---|
| access_status_str | Open Access |
| author | Meyburgh, Pieter Leonardo Du Toit |
| author2 | Vicatos, George |
| author_browse | Meyburgh, Pieter Leonardo Du Toit Vicatos, George |
| author_facet | Vicatos, George Meyburgh, Pieter Leonardo Du Toit |
| author_sort | Meyburgh, Pieter Leonardo Du Toit |
| collection | Thesis |
| description | Includes bibliographical references. |
| format | Thesis |
| id | oai:open.uct.ac.za:11427/9140 |
| institution | University of Cape Town (South Africa) |
| language | eng |
| last_indexed | 2026-06-10T12:48:06.243Z |
| license_str | Not specified — see source repository |
| provenance_str_mv | Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository |
| publishDate | 2014 |
| publishDateRange | 2014 |
| publishDateSort | 2014 |
| publisher | Department of Mechanical Engineering |
| publisherStr | Department of Mechanical Engineering |
| record_format | dspace |
| source_str | UCTD — University of Cape Town Open Access Repository |
| spelling | oai:open.uct.ac.za:11427/9140 Simulation of a power station's condensate pumping system in view of improving its efficiency Meyburgh, Pieter Leonardo Du Toit Vicatos, George Includes bibliographical references. With increasing environmental awareness, higher electricity production costs, and a shortage in electricity supply to the South African grid, increased focus has been placed on the efficiency of power plants, and the improvement thereof. On the majority of the Condensate Extraction Pumps (CEPs) installed in power stations, the flow control is implemented by conventional valve throttling of the discharge valve of these pumps. This type of flow control is uneconomical, as more than 30 of the flow – and the pressure – that can be supplied by the CEPs, is throttled under normal operating conditions. As an energy-efficiency improvement measure, many sources recommend retrofitting of this flow control mechanism with variable speed flow control; but as different applications have different requirements, a need was identified to develop a systematic approach that would assist in determining the feasibility of a variable speed drive (VSD) retrofit. In order to develop this approach, a case study was conducted on an Eskom coal-fired power station – comparing different flow-control techniques with the aid of efficiency calculations, a simulated model, and an economic evaluation. In this case study, an electrical VSD was identified as a feasible retrofit, with an energy saving of 34.6 achievable in pump power consumption at full load conditions. 2014-11-05T03:50:37Z 2014-11-05T03:50:37Z 2014 Master Thesis Masters MEng http://hdl.handle.net/11427/9140 eng application/pdf Department of Mechanical Engineering Faculty of Engineering and the Built Environment University of Cape Town |
| spellingShingle | Meyburgh, Pieter Leonardo Du Toit Simulation of a power station's condensate pumping system in view of improving its efficiency |
| thesis_degree_str | Master's |
| title | Simulation of a power station's condensate pumping system in view of improving its efficiency |
| title_full | Simulation of a power station's condensate pumping system in view of improving its efficiency |
| title_fullStr | Simulation of a power station's condensate pumping system in view of improving its efficiency |
| title_full_unstemmed | Simulation of a power station's condensate pumping system in view of improving its efficiency |
| title_short | Simulation of a power station's condensate pumping system in view of improving its efficiency |
| title_sort | simulation of a power station s condensate pumping system in view of improving its efficiency |
| url | http://hdl.handle.net/11427/9140 |
| work_keys_str_mv | AT meyburghpieterleonardodutoit simulationofapowerstationscondensatepumpingsysteminviewofimprovingitsefficiency |