Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Colorimetric determination of Olanzapine via charge-transfer complexation with Chloranilic Acid.

The charge-transfer complexation (CTC) formed between olanzapine and chloranilic acid have been studied and used as a sensitive colorimetric method for the determination of olanzapine. Evidence for the formation of the CTC between chloranilic acid (CAA) and olanzapine (OLP) was established by spot t...

Full description

Saved in:
Bibliographic Details
Format: Article
Published: 2016
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000njm a2000000a 4500
001 oai:repository.ui.edu.ng:123456789/12090
042 |a dc 
720 |a Adegoke, O. A.  |e author 
720 |a Thomas, O. E.  |e author 
720 |a Emmanuel, S. N.  |e author 
260 |c 2016 
520 |a The charge-transfer complexation (CTC) formed between olanzapine and chloranilic acid have been studied and used as a sensitive colorimetric method for the determination of olanzapine. Evidence for the formation of the CTC between chloranilic acid (CAA) and olanzapine (OLP) was established by spot tests and TLC. Method development was carried out through selection of analytical wavelength, optimization and validation studies. Physicochemical parameters such as energy of transition, transition dipole, oscillator frequency and ionization energies were estimated and related to the stability of the formed CT band. Thermodynamic properties of the CT band at four temperature levels were also estimated and their inter-relationship established. The reaction was completed at room temperature within 10 min with the evidence of formation of purple-coloured solution with CAA that absorbed maximally at 520 nm. Linearity was obtained in the concentration range of 2–40 µg/mL for OLP (r = 0.9977) with a limit of detection of 1.57 µg/mL. Estimates of accuracies and precisions gave error values less than 2% for both intra- and inter-day assessments. The transition energies were of the order of 2.303 eV. The Gibbs energy varied with the temperature and room temperature values favoured formation of stable complexes. The thermodynamic studies revealed small positive entropy for slightly negative enthalpy change. The method was successfully applied to estimate OLP in tablets and the method was found to be of equivalent accuracy with the Indian Pharmacopoeia’s HPLC method (p > 0.05). The method could find application as a rapid and sensitive determination technique for olanzapine. 
024 8 |a 1658-3655 
024 8 |a ui_art_adegoke_colorimetric_2015 
024 8 |a Journal of Taibah University for Science 10(5), pp. 651-663. 
024 8 |a https://repository.ui.edu.ng/handle/123456789/12090 
653 |a Olanzapine 
653 |a Chloranilic acid 
653 |a Charge-transfer complexation 
653 |a Colorimetric analysis 
653 |a Physico-chemical studies 
653 |a Thermodynamic studies 
245 0 0 |a Colorimetric determination of Olanzapine via charge-transfer complexation with Chloranilic Acid.