Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

A survey on the energy consumption and demand in a school

Efforts to reduce energy consumption in domestic buildings and commercial areas have been intensified recently in view of the limiting of the growing demand for electricity and the efforts to reduce CO2 Investigations into energy reduction strategies have been extensive with active and rigorous rese...

Full description

Saved in:
Bibliographic Details
Format: Article
Published: 2010
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000njm a2000000a 4500
001 oai:repository.ui.edu.ng:123456789/1890
042 |a dc 
720 |a Odesola, I. F.  |e author 
260 |c 2010 
520 |a Efforts to reduce energy consumption in domestic buildings and commercial areas have been intensified recently in view of the limiting of the growing demand for electricity and the efforts to reduce CO2 Investigations into energy reduction strategies have been extensive with active and rigorous researches carried out successfully in many countries of the world. A walk-through energy audit was conducted in the School to determine the peak energy demand of the entire School as well as flagged areas for possible energy savings. For the purpose of this study, the School is broken down into about thirty four offices. This paper presents a walk-through energy audit of a School located in Ibadan, Nigeria. A total of about 40.4 kWh of electrical energy per day is required by the School for running all the electrical and mechanical appliances. To reduce the strain on the school's electrical supply systems and hence prevent system outages, the following peak demand reducing strategies have been recommended: Load reducing strategies, High efficiency equipment, Efficient lighting, Efficient air conditioning, Efficient refrigeration, Energy source substitution and on-site heat and electricity generation. It was recommended that this energy audit manual should be used as guide anytime any energy consuming machine is to be installed in the School. 
024 8 |a 1741-5268 
024 8 |a ui_art_odesola_survey_2010 
024 8 |a International Journal of Sustainable Development 3(7), pp. 68-75 
024 8 |a http://ir.library.ui.edu.ng/handle/123456789/1890 
653 |a Load, 
653 |a energy, 
653 |a energy demand, 
653 |a cottsunzpfion, 
653 |a electrical energy 
245 0 0 |a A survey on the energy consumption and demand in a school