Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Correlations for nusselt number in a staggered cross-flow tube-type heat exchanger

Empirical correlations for Nusselt number (Nu) in a staggered multi-row multi-column cross-flow rube-type heat exchanger is presented in this paper. In the experiment, air at ambient temperature was drawn by a centrifugal fan perpendicularly over banks of cylindrical rods arranged in staggered confi...

Full description

Saved in:
Bibliographic Details
Format: Article
Published: 2009
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000njm a2000000a 4500
001 oai:repository.ui.edu.ng:123456789/1933
042 |a dc 
720 |a Fadare, D. A. D. A.  |e author 
260 |c 2009 
520 |a Empirical correlations for Nusselt number (Nu) in a staggered multi-row multi-column cross-flow rube-type heat exchanger is presented in this paper. In the experiment, air at ambient temperature was drawn by a centrifugal fan perpendicularly over banks of cylindrical rods arranged in staggered configuration of 5 rows by 4 columns. A test element consisting of a tube of copper with length, internal and external diameters of 0.125, 0.0115 and 0.0125 m was heated to a maximum temperature of about 90°C and inserted into the air stream in the working section. Rate of cooling was measured by thermocouple embedded at the centre, via a digital multimeter which was connected to a computer for monitoring temperature data. A semi-logarithms plot of the data was used to calculate the heat transfer coefficient (h) between the copper element and air, and hence the Nusselt number. The heat transfer coefficient at the centre of each of the four columns at ten different flow rates with throttle valve openings ranging from 10 - 100% were investigated. Results showed that the Nusselt number increased exponentially with increase in air flow rate and also increased in successive columns in the direction of flow at a diminishing rate. Correlations of Nusselt number with Reynolds number (Re) were developed for preliminary design and performance assessment of staggered multi-row multi-column cross-flow tube-type heat exchanger. 
024 8 |a 1115-9782 
024 8 |a ui_art_fadare_correlations_2009 
024 8 |a Ife Journal of Technology 18(2), pp. 11-14 
024 8 |a http://ir.library.ui.edu.ng/handle/123456789/1933 
245 0 0 |a Correlations for nusselt number in a staggered cross-flow tube-type heat exchanger