Electromagnetic profiling for groundwater in precambrian basement complex areas of Nigeria

Ground electromagnetic profiling, using a Geonics EM34-3 instrument, has been employed to identify areas of high conductivity in a Precambrian basement complex terrain of Nigeria. Field examples, conducted as part of a rural water supply programme, are presented. They indicate that the apparent cond...

Full description

Saved in:
Bibliographic Details
Format: Article
Published: 1990
Tags: Add Tag
No Tags, Be the first to tag this record!

MARC

LEADER 00000njm a2000000a 4500
001 oai:repository.ui.edu.ng:123456789/5431
042 |a dc 
720 |a Olayinka, A.I.  |e author 
260 |c 1990 
520 |a Ground electromagnetic profiling, using a Geonics EM34-3 instrument, has been employed to identify areas of high conductivity in a Precambrian basement complex terrain of Nigeria. Field examples, conducted as part of a rural water supply programme, are presented. They indicate that the apparent conductivities are generally lower than about 60 mmho m-1. Subsequent borehole drilling suggests a good correlation between high EM34 anomalies, deep weathering and high well yield (> 1 1 s-1). On the other hand, boreholes sited on conductivity lows penetrated a thinner regolith with relatively lower yields. 
024 8 |a Nordic Hydrology, 21, 1990. Pp. 205-216 
024 8 |a ui_art_olayinka.a.i_electromagnetic_1990 
024 8 |a http://ir.library.ui.edu.ng/handle/123456789/5431 
245 0 0 |a Electromagnetic profiling for groundwater in precambrian basement complex areas of Nigeria