Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Enantioselective sensors and biosensors for clinical analysis

Thesis (PhD (Chemistry))--University of Pretoria, 2006.

Saved in:
Bibliographic Details
Other Authors: Stefan, Raluca-Ioana
Format: Thesis
Published: University of Pretoria 2013
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613566931042304
access_status_str Open Access
author2 Stefan, Raluca-Ioana
author_browse Stefan, Raluca-Ioana
author_facet Stefan, Raluca-Ioana
collection Thesis
dc_rights_str_mv © 2005, University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria.
description Thesis (PhD (Chemistry))--University of Pretoria, 2006.
format Thesis
id oai:repository.up.ac.za:2263/24676
institution University of Pretoria (South Africa)
last_indexed 2026-06-10T12:38:11.690Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from UPSpace — University of Pretoria Institutional Repository
publishDate 2013
publishDateRange 2013
publishDateSort 2013
publisher University of Pretoria
publisherStr University of Pretoria
record_format dspace
source_str UPSpace — University of Pretoria Institutional Repository
spelling oai:repository.up.ac.za:2263/24676 Enantioselective sensors and biosensors for clinical analysis Stefan, Raluca-Ioana upetd@ais.up.ac.za Nejem, R'afat Mahmoud No key words available UCTD Thesis (PhD (Chemistry))--University of Pretoria, 2006. The enantioanalysis of compounds of biological importance with a chiral moiety is very important because each enantiomer is a marker for a different disease. Accordingly, very reliable methods of enantioanalysis should be employed for the correct diagnosis of the diseases. The utilization of amperometric biosensors and enantioselective, potentiometric membrane electrodes made the assay of a single enantiomer faster, easier and more reliable if one compare with the chromatographic techniques which are widely proposed for this kind of analyses. Monocrystalline diamond was proposed as matrix for amperometric electrodes and amperometric biosensors design. The advantages of using such material for electrode design are: (a) lower background currents and noise signals, which lead to improve S/B and S/N ratios, and lower detection limits; (b) good electrochemical activity (pre-treatment is not necessary); (c) wide electrochemical potential window in aqueous media; (d) very low capacitance; (e) extreme electrochemical stability; and (f) high reproducibility of analytical information. The design selected for the electrodes is simple, fast and reproducible. The carbon or diamond powders were mixed with paraffine oil to give the carbon or diamond paste which can act alone as electroactive material in the electrodes or it can be modified with a chiral selector (e.g., cyclodextrins, maltodextrins or antibiotics) or enzyme (e.g., L(D)-aminoacid oxidase, L-lysine oxidase). The results obtained by employing the amperometric electrodes and biosensors and the enantioselective, potentiometric membrane electrodes proved a high sensitivity, selectivity, accuracy and high reliability. These characteristics made them suitable to be used for the enantioanalysis of different compounds of biological importance (e.g., pipecolic acid, glyceric acid, 2-hydroxyglyceric acid, fucose, L-vesamicol and L-lysine) in serume and/or urine samples. The features of the proposed enantioselective, amperometric and potentiometric electrodes proposed in this thesis are their utilization for in vivo measurements and as detectors in flow systems (flow injection analysis or/and sequential injection analysis). This will simplify the enantioanalysis and will improve considerable the reliability of the analytical information favorazing a fast and accurate diagnosis of the diseases associated with the marker determined. Chemistry unrestricted 2013-09-06T18:09:19Z 2005-01-24 2013-09-06T18:09:19Z 2005-05-08 2006-01-24 2005-01-24 Thesis Nejem, R 2005, Enantioselective sensors and biosensors for clinical analysis, PhD thesis, University of Pretoria, Pretoria, viewed yymmdd < http://hdl.handle.net/2263/24676 > http://hdl.handle.net/2263/24676 http://upetd.up.ac.za/thesis/available/etd-01242005-114455/ © 2005, University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf application/pdf University of Pretoria
spellingShingle No key words available
UCTD
Enantioselective sensors and biosensors for clinical analysis
title Enantioselective sensors and biosensors for clinical analysis
title_full Enantioselective sensors and biosensors for clinical analysis
title_fullStr Enantioselective sensors and biosensors for clinical analysis
title_full_unstemmed Enantioselective sensors and biosensors for clinical analysis
title_short Enantioselective sensors and biosensors for clinical analysis
title_sort enantioselective sensors and biosensors for clinical analysis
topic No key words available
UCTD
url http://hdl.handle.net/2263/24676
http://upetd.up.ac.za/thesis/available/etd-01242005-114455/