Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Development of an on-line entrainment measurement device for a bubbling fluidized bed

Dissertation (MEng)--University of Pretoria, 2012.

Saved in:
Bibliographic Details
Other Authors: Du Toit, Elizabeth Louisa
Format: Thesis
Published: University of Pretoria 2013
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613537695694848
access_status_str Open Access
author2 Du Toit, Elizabeth Louisa
author_browse Du Toit, Elizabeth Louisa
author_facet Du Toit, Elizabeth Louisa
collection Thesis
dc_rights_str_mv © 2012 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria
description Dissertation (MEng)--University of Pretoria, 2012.
format Thesis
id oai:repository.up.ac.za:2263/25312
institution University of Pretoria (South Africa)
last_indexed 2026-06-10T12:37:43.693Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from UPSpace — University of Pretoria Institutional Repository
publishDate 2013
publishDateRange 2013
publishDateSort 2013
publisher University of Pretoria
publisherStr University of Pretoria
record_format dspace
source_str UPSpace — University of Pretoria Institutional Repository
spelling oai:repository.up.ac.za:2263/25312 Development of an on-line entrainment measurement device for a bubbling fluidized bed Du Toit, Elizabeth Louisa Nicol, Willie st26482462@gmail.com Muller, Maria Aletta Solid mass flow meter Entrainment rate Bubbling fluidized bed UCTD Dissertation (MEng)--University of Pretoria, 2012. A selective combination of the principles of a thermal mass flow meter and constant temperature anemometry was used to develop a solid mass flow meter that improves significantly on the flow meter developed by De Vos et al (2010). The flow meter has a measurement plate that is kept at a constant temperature. Due to conductive heat transfer between the entrained solids and the measurement plate, additional power is needed to maintain the plate at this setpoint temperature value. This additional power was correlated against the average solids flow rate. The calibration curve shows a linear relationship between the power measurement and the entrainment flux for entrainment fluxes between 3.4 x 10-4 kg/(m2.s) and 7.5 x 10-3 kg/(m2.s). Deviation from a linear response at lower entrainment fluxes may be caused by a longer residence time of fine particles on the measurement plate due to lower shear forces. At higher entrainment fluxes the power measurements were unreliable due to poor temperature control. The turndown ratio of the linear section of the calibration curve is approximately 3 times that of the linear part of the calibration curve of the flow meter developed by De Vos et al (2010). Even further improvement is possible with better temperature control. In a case study to test the applicability of the flow meter to measure changes in entrainment rate associated with hydrodynamic properties other than a change in gas superficial velocity, small amounts of ethanol were dosed to the inlet air. The continuously measured entrainment rate increased at lower ethanol dosing rates but decreased as the dosing rate of ethanol was increased. The increase in entrainment rate may be explained by a reduction in static electricity in the bed, while the decrease at higher dosing rates may be as a result of increased powder cohesivity. Chemical Engineering unrestricted 2013-09-06T20:37:12Z 2013-06-07 2013-09-06T20:37:12Z 2013-04-04 2012 2013-06-06 Dissertation Muller, MA 2012, Development of an on-line entrainment measurement device for a bubbling fluidized bed, MEng dissertation, University of Pretoria, Pretoria, viewed yymmdd < http://hdl.handle.net/2263/25312 > E13/4/719/gm http://hdl.handle.net/2263/25312 http://upetd.up.ac.za/thesis/available/etd-06062013-125215/ © 2012 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria application/pdf University of Pretoria
spellingShingle Solid mass flow meter
Entrainment rate
Bubbling fluidized bed
UCTD
Development of an on-line entrainment measurement device for a bubbling fluidized bed
title Development of an on-line entrainment measurement device for a bubbling fluidized bed
title_full Development of an on-line entrainment measurement device for a bubbling fluidized bed
title_fullStr Development of an on-line entrainment measurement device for a bubbling fluidized bed
title_full_unstemmed Development of an on-line entrainment measurement device for a bubbling fluidized bed
title_short Development of an on-line entrainment measurement device for a bubbling fluidized bed
title_sort development of an on line entrainment measurement device for a bubbling fluidized bed
topic Solid mass flow meter
Entrainment rate
Bubbling fluidized bed
UCTD
url http://hdl.handle.net/2263/25312
http://upetd.up.ac.za/thesis/available/etd-06062013-125215/