Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Hearing protection in mines : evaluating the Noise Clipper® custom made hearing protection device

Dissertation (MCommunication Pathology)--University of Pretoria, 2013.

Saved in:
Bibliographic Details
Other Authors: Soer, Maggi E. (Magdalena Elizabeth)
Format: Thesis
Published: University of Pretoria 2013
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613435343142912
access_status_str Open Access
author2 Soer, Maggi E. (Magdalena Elizabeth)
author_browse Soer, Maggi E. (Magdalena Elizabeth)
author_facet Soer, Maggi E. (Magdalena Elizabeth)
collection Thesis
dc_rights_str_mv © 2013 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria
description Dissertation (MCommunication Pathology)--University of Pretoria, 2013.
format Thesis
id oai:repository.up.ac.za:2263/25539
institution University of Pretoria (South Africa)
last_indexed 2026-06-10T12:36:06.245Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from UPSpace — University of Pretoria Institutional Repository
publishDate 2013
publishDateRange 2013
publishDateSort 2013
publisher University of Pretoria
publisherStr University of Pretoria
record_format dspace
source_str UPSpace — University of Pretoria Institutional Repository
spelling oai:repository.up.ac.za:2263/25539 Hearing protection in mines : evaluating the Noise Clipper® custom made hearing protection device Soer, Maggi E. (Magdalena Elizabeth) Vinck, Bart M. jkock@noiseclipper.co.za Kock, Johan Frederick Willem Temporary threshold shift Biological threshold for temporary threshold shift Noise reduction Noise induced hearing loss Permanent threshold shift UCTD Dissertation (MCommunication Pathology)--University of Pretoria, 2013. Noise induced hearing loss has been extensively researched and commented on, yet it remains prevalent among industrial workers. The real-world attenuation properties of the Noise Clipper® custom-made hearing protection device and the comfort levels it afford are unknown. Furthermore, research in hearing conservation is seldom focused on the critical/biological thresholds for temporary threshold shift. Field studies on hearing protection devices have demonstrated that laboratory derived measures bear little relation to attenuation achieved in workers. Research has consistently demonstrated that noise reduction ratings that are derived from the laboratory real-ear-at-threshold method do not accurately represent the attenuation of noise that these devices actually provide and the matter remains unclear. Too many important variables are neglected in current real-ear-atthreshold evaluation protocols. This study used an alternative method, the microphone-inreal- ear approach where a dual-element microphone probe was inserted into the Noise Clipper® to measure noise reduction by recording the difference in noise levels outside and behind the device. The sub aims of the study were to record ambient noise levels and frequency spectra; to determine the attenuation characteristics; and to compare the attenuation thresholds to biological thresholds for temporary threshold shift. Using this protocol, measurements were made on 20 subjects in real world situations in order to match the attenuation characteristics of the Noise Clipper® to the actual noise exposure. The microphone-in-real-ear derived attenuation thresholds were compared to the real-earat- threshold values provided by the manufacturer of the Noise Clipper®. Additional subaims were to determine the comfort levels of the Noise Clipper® and record the selfreported wearing time of the device. Wearing comfort was evaluated using a bipolar rating scale. The researcher interviewed 240 mine workers at a platinum mine. Several comfort related sub-scales were used to quantify reported comfort levels. Simultaneously, usage time of the device was self-reported by each worker. Results of the microphone-in-real-ear measurements indicated that ambient noise levels fluctuated from day to day. The attenuation results indicated that most of the measurements suggested protection against noise induced hearing loss through the use of the Noise Clipper®. It was found that the REAT results over estimated the attenuation ability of the Noise Clipper® when compared to the results of the F-MIRE measurements. Eighty seven percent of the measurements indicated protection from thresholds below the biological threshold for temporary threshold shift. Seventy five percent of the workers indicated that the Noise Clipper® was comfortable to wear and 79% indicated that they used it for a full eight hour shift. The results provide an opportunity to assess the use of a protection device and its effectiveness among mineworkers combined with information regarding noise exposure levels. The findings highlight the importance of evaluating variability in terms of individual-specific protection. Speech-Language Pathology and Audiology unrestricted 2013-09-06T22:21:01Z 2013-06-14 2013-09-06T22:21:01Z 2013-04-11 2013-06-14 2013-06-14 Dissertation Kock, JFW 2013, Hearing protection in mines : evaluating the Noise Clipper® custom made hearing protection device, MCommunication Pathology dissertation, University of Pretoria, Pretoria, viewed yymmdd < http://hdl.handle.net/2263/25539 > E13/4/740/gm http://hdl.handle.net/2263/25539 http://upetd.up.ac.za/thesis/available/etd-06142013-115026/ © 2013 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria application/pdf University of Pretoria
spellingShingle Temporary threshold shift
Biological threshold for temporary threshold shift
Noise reduction
Noise induced hearing loss
Permanent threshold shift
UCTD
Hearing protection in mines : evaluating the Noise Clipper® custom made hearing protection device
title Hearing protection in mines : evaluating the Noise Clipper® custom made hearing protection device
title_full Hearing protection in mines : evaluating the Noise Clipper® custom made hearing protection device
title_fullStr Hearing protection in mines : evaluating the Noise Clipper® custom made hearing protection device
title_full_unstemmed Hearing protection in mines : evaluating the Noise Clipper® custom made hearing protection device
title_short Hearing protection in mines : evaluating the Noise Clipper® custom made hearing protection device
title_sort hearing protection in mines evaluating the noise clipper r custom made hearing protection device
topic Temporary threshold shift
Biological threshold for temporary threshold shift
Noise reduction
Noise induced hearing loss
Permanent threshold shift
UCTD
url http://hdl.handle.net/2263/25539
http://upetd.up.ac.za/thesis/available/etd-06142013-115026/