Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators

Dissertation (MEd (Mechanical Engineering))--University of Pretoria, 2006.

Saved in:
Bibliographic Details
Other Authors: Burger, N.D.L (Nicolaas Daniel Lombard)
Format: Thesis
Published: University of Pretoria 2013
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613526015606784
access_status_str Open Access
author2 Burger, N.D.L (Nicolaas Daniel Lombard)
author_browse Burger, N.D.L (Nicolaas Daniel Lombard)
author_facet Burger, N.D.L (Nicolaas Daniel Lombard)
collection Thesis
dc_rights_str_mv © 2005, University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria.
description Dissertation (MEd (Mechanical Engineering))--University of Pretoria, 2006.
format Thesis
id oai:repository.up.ac.za:2263/26728
institution University of Pretoria (South Africa)
last_indexed 2026-06-10T12:37:32.711Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from UPSpace — University of Pretoria Institutional Repository
publishDate 2013
publishDateRange 2013
publishDateSort 2013
publisher University of Pretoria
publisherStr University of Pretoria
record_format dspace
source_str UPSpace — University of Pretoria Institutional Repository
spelling oai:repository.up.ac.za:2263/26728 Tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators Burger, N.D.L (Nicolaas Daniel Lombard) tertius.opperman@sasol.com Opperman, Tertius Wear Wear debris Non-newtonian Lubricity Lubricant Viscosity Joint fluid Synovial fluid Simulator Hip UCTD Dissertation (MEd (Mechanical Engineering))--University of Pretoria, 2006. Over the years, different lubricants have been used to operate hip simulators. The current applicable ISO standard (ISO 14242-1:2002) recommends the use of 25% calf serum diluted with deionised water. The standard further recommends that the fluid be changed and the acetabular cup be weighed every 500 000 cycles. This procedure results in a loss of both the third body wear particles and the wear pattern. The purpose of this study was to develop a synthetic lubricant that would map the viscosity and lubricity properties of joint fluid (“synovial fluid”) over the whole duration of a simulator test, which is typically five million cycles. The first objective of this study was to find the effect of temperature increase on the viscous and lubricative properties of joint fluid retrieved from both primary and revision patients prior to surgery. The lubricity tests were done on a Linear-Oscillation Test Machine (SRV machine). Three test temperatures were used namely 38ºC, 50ºC and 60ºC. The load at failure and the average coefficient of friction were parameters measured during these tests. A decrease in the load at failure was found for an increase in test temperature, while the coefficient of friction stayed relatively stable. The viscosity tests were done using a Brookfield Viscometer. The three test temperatures mentioned above, were copied. The joint fluid tested showed pseudoplastic flow behaviour. An increase in the viscosity as a function of test temperature increase and a magnitude of shear rate was observed. The second objective of this study was to develop a synthetic lubricant that had the same average properties than that found for the retrieved joint fluid. A mixture of three different chemicals, namely Poloxamer 188, Xanthan Gum and Lube Boosterâ II was used to map the viscous and lubricative properties of the joint fluid. A comparative test using the synthetic lubricant and bovine serum was performed in a custom-built simulator. Wear debris was sampled at 500 000 cycle intervals up to 4 500 000 cycles. During these intervals the bovine serum stations were drained and washed with deionised water, but not stripped and weighed as specified in the ISO standard. This was done intentionally to preserve the wear pattern during the entire test. The synthetic lubricant stations were not stripped or drained during these intervals. This ensured that the wear pattern was maintained and that the effect of accumulative wear could be investigated throughout the duration of the test. The wear debris from the test was then compared to wear debris retrieved from scar tissue of revision patients. The wear debris that was found in the scar tissue retrieved from patients was similar in shape and size to that which was found in the simulator using bovine serum and the synthetic lubricant. It can thus be concluded that an acceptable lubricant had been developed to replace the current test medium in the simulators. Mechanical and Aeronautical Engineering unrestricted 2013-09-07T07:26:25Z 2005-07-28 2013-09-07T07:26:25Z 2005-02-08 2006-07-28 2005-07-28 Dissertation Opperman, T 2005, Tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators, MEd dissertation, University of Pretoria, Pretoria, viewed yymmdd < http://hdl.handle.net/2263/26728 > http://hdl.handle.net/2263/26728 http://upetd.up.ac.za/thesis/available/etd-07282005-083909/ © 2005, University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. application/pdf application/pdf application/pdf application/pdf University of Pretoria
spellingShingle Wear
Wear debris
Non-newtonian
Lubricity
Lubricant
Viscosity
Joint fluid
Synovial fluid
Simulator
Hip
UCTD
Tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators
title Tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators
title_full Tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators
title_fullStr Tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators
title_full_unstemmed Tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators
title_short Tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators
title_sort tribological evaluation of joint fluid and the development of a synthetic lubricant for use in hip joint simulators
topic Wear
Wear debris
Non-newtonian
Lubricity
Lubricant
Viscosity
Joint fluid
Synovial fluid
Simulator
Hip
UCTD
url http://hdl.handle.net/2263/26728
http://upetd.up.ac.za/thesis/available/etd-07282005-083909/