Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Development of a validated thermal model for the slow-cool process of Waterval Converter Matte

Dissertation (MEng)--University of Pretoria, 2013.

Saved in:
Bibliographic Details
Other Authors: De Villiers, Johan Pieter
Format: Thesis
Language:English
Published: University of Pretoria 2014
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613543036092417
access_status_str Open Access
author2 De Villiers, Johan Pieter
author_browse De Villiers, Johan Pieter
author_facet De Villiers, Johan Pieter
collection Thesis
dc_rights_str_mv © 2013 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria.
description Dissertation (MEng)--University of Pretoria, 2013.
format Thesis
id oai:repository.up.ac.za:2263/33335
institution University of Pretoria (South Africa)
language English
last_indexed 2026-06-10T12:37:48.825Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from UPSpace — University of Pretoria Institutional Repository
publishDate 2014
publishDateRange 2014
publishDateSort 2014
publisher University of Pretoria
publisherStr University of Pretoria
record_format dspace
source_str UPSpace — University of Pretoria Institutional Repository
spelling oai:repository.up.ac.za:2263/33335 Development of a validated thermal model for the slow-cool process of Waterval Converter Matte De Villiers, Johan Pieter De Villiers, Lambert Petrus van Sittert The Anglo American Platinum Converter Plant Waterval Converter Matte (WCM) UCTD Dissertation (MEng)--University of Pretoria, 2013. The Anglo American Platinum Converter Plant produces a copper-nickel sulphide converter matte which is slow-cooled in ingots over several days. During the process, the formation of alloy platelets, containing the majority of the PGM’s and Au, occurs. The alloy forms a magnetic fraction in the bulk matte which can be liberated when the matte is crushed and milled. The alloy platelets are then separated via a magnetic separation process in the Magnetic Concentration plant. The quality of the converter matte is dependent on the reaction and cast temperatures, bulk matte composition and cooling rate of each ingot, which define the microstructure of the slow-cooled matte that is produced as the final product of the ACP process. The current mould size used in the ACP slow-cool aisle is ~10 tonnes (maximum 14.84t), designed for 2 full ingots to be poured from every tap from a full ladle with a capacity of ~20t. This is the ideal situation, however, during normal plant operation ladles develop a build-up of material on the inside (or skull) that reduces the ladle active volume. This results in a large number of half ingots being produced, and, given the smaller ingot size, suboptimal cooling conditions arise and subsequently poor quality Waterval Converter Matte (WCM) is produced because of rapid cooling. In an attempt to match the converter blow size, the ladle size and the slow-cool mould size in future, a larger mould size of 15 ton was specifically constructed to determine if the smelter converted matte can be cast into the larger mould size. Therefore a larger size ingot of 15t with a maximum capacity of 20.6t was also used as part of the trials in order to determine if cooling rates in the larger sized ingot necessitated longer cooling times, and would therefore negatively affect the platinum pipeline and working inventory. The data obtained from these trials were then used to develop and validate a CFD model, specifically developed to simulate the cooling process. From the heat loss data it was calculated that the bulk of the heat lost from the ingots is through the top surface. After the first 12 hours of cooling, approximately 89% of the heat lost from the ingot is via the top surface and this increases to 96% after 24 hours. It can therefore be concluded that the cooling rates of the ingots can be easily manipulated by changing the thermal insulation of the lid that is placed over the ingot after casting. gm2014 Materials Science and Metallurgical Engineering unrestricted 2014-02-11T05:10:52Z 2014-02-11T05:10:52Z 2013-09-04 2013 Dissertation De Villiers, LPVS 2013, Development of a validated thermal model for the slow-cool process of Waterval Converter Matte, MEng dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/33335> E13/9/1007/gm http://hdl.handle.net/2263/33335 en © 2013 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. application/pdf University of Pretoria
spellingShingle The Anglo American Platinum Converter Plant
Waterval Converter Matte (WCM)
UCTD
Development of a validated thermal model for the slow-cool process of Waterval Converter Matte
title Development of a validated thermal model for the slow-cool process of Waterval Converter Matte
title_full Development of a validated thermal model for the slow-cool process of Waterval Converter Matte
title_fullStr Development of a validated thermal model for the slow-cool process of Waterval Converter Matte
title_full_unstemmed Development of a validated thermal model for the slow-cool process of Waterval Converter Matte
title_short Development of a validated thermal model for the slow-cool process of Waterval Converter Matte
title_sort development of a validated thermal model for the slow cool process of waterval converter matte
topic The Anglo American Platinum Converter Plant
Waterval Converter Matte (WCM)
UCTD
url http://hdl.handle.net/2263/33335