A Decision analysis guideline for underground bulk air heat exchanger design specifications

Dissertation (MEng)--University of Pretoria, 2013.

Saved in:
Bibliographic Details
Other Authors: Webber-Youngman, R.C.W.
Format: Thesis
Language:English
Published: University of Pretoria 2014
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613720716247040
access_status_str Open Access
author2 Webber-Youngman, R.C.W.
author_browse Webber-Youngman, R.C.W.
author_facet Webber-Youngman, R.C.W.
collection Thesis
dc_rights_str_mv © 2014 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria.
description Dissertation (MEng)--University of Pretoria, 2013.
format Thesis
id oai:repository.up.ac.za:2263/41006
institution University of Pretoria (South Africa)
language English
last_indexed 2026-06-10T12:40:38.203Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from UPSpace — University of Pretoria Institutional Repository
publishDate 2014
publishDateRange 2014
publishDateSort 2014
publisher University of Pretoria
publisherStr University of Pretoria
record_format dspace
source_str UPSpace — University of Pretoria Institutional Repository
spelling oai:repository.up.ac.za:2263/41006 A Decision analysis guideline for underground bulk air heat exchanger design specifications Webber-Youngman, R.C.W. mhooman@bbe.co.za Du Plessis, J.J.L. Hooman, Marle Underground bulk air heat exchanger Air cooler Heat rejection Copper mine UCTD Dissertation (MEng)--University of Pretoria, 2013. This study investigated different underground bulk air heat exchanger (>100 m3/s) design criteria. It was found that no single document exist covering these heat exchangers and therefore the need was identified to generate a guideline with decision analyser steps to arrive at a technical specification. The study investigated the factors influencing the heat exchanger designs (spray chambers, towers and indirect-contact heat exchangers) and the technical requirements for each. The decision analysers can be used to generate optimised user-friendly fit-for-purpose bulk air heat exchanger (air cooler and heat rejection) designs. The study was tested against a constructed air cooler and heat rejection unit at a copper mine. It was concluded that the decision analysers were used successfully. It is recommended design engineers use these decision analysers to effectively design other heat exchangers. gm2014 Mining Engineering unrestricted 2014-07-30T07:39:58Z 2014-07-30T07:39:58Z 2014-04-16 2013 Dissertation Hooman, M 2013, A Decision analysis guideline for underground bulk air heat exchanger design specifications, MEng dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/41006> E14/4/308/gm http://hdl.handle.net/2263/41006 en © 2014 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. application/pdf University of Pretoria
spellingShingle Underground bulk air heat exchanger
Air cooler
Heat rejection
Copper mine
UCTD
A Decision analysis guideline for underground bulk air heat exchanger design specifications
title A Decision analysis guideline for underground bulk air heat exchanger design specifications
title_full A Decision analysis guideline for underground bulk air heat exchanger design specifications
title_fullStr A Decision analysis guideline for underground bulk air heat exchanger design specifications
title_full_unstemmed A Decision analysis guideline for underground bulk air heat exchanger design specifications
title_short A Decision analysis guideline for underground bulk air heat exchanger design specifications
title_sort decision analysis guideline for underground bulk air heat exchanger design specifications
topic Underground bulk air heat exchanger
Air cooler
Heat rejection
Copper mine
UCTD
url http://hdl.handle.net/2263/41006