Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Detection of acetone using nanostructured WO3 for diabetes mellitus monitoring applications

Thesis (PhD (Biochemistry))--University of Pretoria, 2020.

Saved in:
Bibliographic Details
Other Authors: Beukes, Mervyn
Format: Thesis
Language:en_US
Published: University of Pretoria 2020
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613632937852928
access_status_str Open Access
author2 Beukes, Mervyn
author_browse Beukes, Mervyn
author_facet Beukes, Mervyn
collection Thesis
dc_rights_str_mv © 2019 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria.
description Thesis (PhD (Biochemistry))--University of Pretoria, 2020.
format Thesis
id oai:repository.up.ac.za:2263/75313
institution University of Pretoria (South Africa)
language en_US
last_indexed 2026-06-10T12:39:14.512Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from UPSpace — University of Pretoria Institutional Repository
publishDate 2020
publishDateRange 2020
publishDateSort 2020
publisher University of Pretoria
publisherStr University of Pretoria
record_format dspace
source_str UPSpace — University of Pretoria Institutional Repository
spelling oai:repository.up.ac.za:2263/75313 Detection of acetone using nanostructured WO3 for diabetes mellitus monitoring applications Beukes, Mervyn valentinesaasa@gmail.com Mwakikunga, Bonex W. Lemmer, Yolandy Saasa, Raseputuka Valentine UCTD Thesis (PhD (Biochemistry))--University of Pretoria, 2020. Diabetes mellitus which is characterized by a high levels of blood glucose is a major source of mortality, morbidity and health costs worldwide. Major gaps exist in efforts to comprehend the burden nationally and globally, especially in developing nations, due to a lack of accurate, cheap and non-invasive data and devices for monitoring and surveillance. In Africa, type 2 diabetes mellitus represents 90% of diabetes cases. The disease mainly relies on management and monitoring. Although reliable blood glucose monitoring techniques and devices exist worldwide, the challenge is with the cost, invasiveness, and long sample preparation. Herein this study, the challenge was addressed by synthesizing WO3 materials for the detection of acetone in a simulated human breath. Acetone has been reliably confirmed to be the biomarker of diabetes mellitus. The Gas Chromatography-Mass Spectrometry (GC-MS) was employed to quantify acetone in type 2 diabetes mellitus. A statistically significant correlation (R=0.756) between blood glucose and breath acetone was observed, between blood acetoacetate and breath acetone (R=0,897), and between beta-hydroxybutyrate and breath acetone (R=0,821). Furthermore, we used semiconducting metal oxide (WO3) to investigate its selectivity, sensitivity, and response towards acetone. Semiconducting metal oxides sensor has the potential to detect volatile organic compound (VOCs) at low concentrations as low as 0.1 ppb. Other advantages of semiconducting metal oxides sensors include, facile and cheap device fabrication, portability, real-time analysis, and facile operating principle. We used two synthesis methods for fabrication of acetone sensors namely solvothermal method whereby solvent ratios were varied, and the sol-gel method where carbon nanospheres were used as a template and cobalt as a dopant. The sensor fabricated with 51:49 water: ethanol is found to demonstrate high response and good selectivity to 2 ppm level of acetone when compared with the one fabricated with pure ethanol, 18:92 (ethanol: water) and 92% water. Furthermore, the sensor could respond to low concentrations of acetone ranging from 0.5 to 4.5 ppm of acetone at 100 °C. For the sol-gel method, the 0.6 % Co-doped WO3 showed higher response and selectivity towards acetone gas from as low as 0.5 ppm at a very low operating temperature of 50 °C. Contrary, there was a very low response from other gases including toluene, NO2, NH3, CH4 and H2S operating at a similar temperature. This highlights the acetone selectivity of our 0.6 % Co-doped WO3 sample. Based on the two methods used for the synthesis of the acetone sensor, we can conclude that the Co-doped sensor shows better performance as compared to the as-prepared WO3. This is from the findings that the Co-doped WO3 can respond and select acetone concentration at 50 ◦C, which is a very low temperature in comparison to other platforms described in literature. An envisioned portable point of care diabetic device could therefore be operated at 50 ◦C in any point of care setting. Council for Scientific and Industrial Research Biochemistry PhD (Biochemistry) Unrestricted 2020-07-16T12:47:39Z 2020-07-16T12:47:39Z 2020 2020 Thesis Saasa, RV 2020, Detection of acetone using nanostructured WO3 for diabetes mellitus monitoring applications, PhD (Biochemistry) Thesis, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/75313> S2020 http://hdl.handle.net/2263/75313 en_US © 2019 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. application/pdf University of Pretoria
spellingShingle UCTD
Detection of acetone using nanostructured WO3 for diabetes mellitus monitoring applications
title Detection of acetone using nanostructured WO3 for diabetes mellitus monitoring applications
title_full Detection of acetone using nanostructured WO3 for diabetes mellitus monitoring applications
title_fullStr Detection of acetone using nanostructured WO3 for diabetes mellitus monitoring applications
title_full_unstemmed Detection of acetone using nanostructured WO3 for diabetes mellitus monitoring applications
title_short Detection of acetone using nanostructured WO3 for diabetes mellitus monitoring applications
title_sort detection of acetone using nanostructured wo3 for diabetes mellitus monitoring applications
topic UCTD
url http://hdl.handle.net/2263/75313