Application of a smartphone modulated ECG device for use in equines

Dissertation (MSc)--University of Pretoria, 2019.

Saved in:
Bibliographic Details
Other Authors: Schliewert, Eva-Christina
Format: Thesis
Language:English
Published: University of Pretoria 2020
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613652558807040
access_status_str Open Access
author2 Schliewert, Eva-Christina
author_browse Schliewert, Eva-Christina
author_facet Schliewert, Eva-Christina
collection Thesis
dc_rights_str_mv © 2020 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria.
description Dissertation (MSc)--University of Pretoria, 2019.
format Thesis
id oai:repository.up.ac.za:2263/76762
institution University of Pretoria (South Africa)
language English
last_indexed 2026-06-10T12:39:33.363Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from UPSpace — University of Pretoria Institutional Repository
publishDate 2020
publishDateRange 2020
publishDateSort 2020
publisher University of Pretoria
publisherStr University of Pretoria
record_format dspace
source_str UPSpace — University of Pretoria Institutional Repository
spelling oai:repository.up.ac.za:2263/76762 Application of a smartphone modulated ECG device for use in equines Schliewert, Eva-Christina u12000842@tuks.co.za Williams, Adele Piketh, Graeme UCTD Dissertation (MSc)--University of Pretoria, 2019. Introduction Reason for performing the study: This research was performed to determine whether a novel ECG device, that uses smartphone technologies and applications, can be used to obtain electrocardiogram (ECG) readings in horses. Objectives: The main objectives of the present study focused on determining the best method of application for the Alivecor KardiaMobilea (ECGAKM) smartphone modulated electrocardiographic device in horses including body site, skin preparation as well as device orientation. The study also focused on the comparison to the Televet 100 (ECGTV) electrocardiographic device which is commonly employed for ECG recordings in horses. Study design A cross sectional study. Materials and Methods Research was completed in two parts. In the first part, 36 Nooitgedacht pony mares were used to determine the best site of application, method of skin preparation as well as ECGAKM device orientation for reliable ECG tracings. The different body sites for application of the device included the fourth intercostal space of the left thorax, fourth intercostal space of the right thorax and right triceps muscle mass. The automatically calculated heart rate from the device application was compared to that acquired via auscultation. Once the best method of ECGAKM application had been established, 31 Nooitgedacht pony mares were used to compare the device with a standard ECGTV device. ECG tracings were evaluated for agreement between the two devices considering the PQ, RR, QT and QRS intervals as well as the overall rhythm assessment for the ECG devices. Results The ECGAKM device is best applied in the fourth intercostal space on the left hemithorax in a vertical orientation with reference to the ground and with the skin dampened with 70 % alcohol. Using this configuration, the ECGAKM device was able to achieve acquisition of complete decipherable ECG tracings in 91.67 % of readings. Arrhythmias were noted in 3/31 horses and were determined to conform to sinoatrial blockade/arrest in both the ECGAKM and ECGTV tracings. Independent t tests conducted on the mean values for RR; QT and QRS intervals yielded p-values of 0.73; 1 and 0 respectively. As such the mean values determined for RR and QT intervals were not significantly different, however it was determined that the mean values for the QRS interval were significantly different for the two devices. Independent-samples Mann Whitney U test indicated that the distribution of values of mean PQ interval were the same over the ECGAKM and ECGTV categories. These values for PQ, RR, QT, and QRS intervals were then also analysed using Bland-Altman plots. Discussion and Conclusion The left fourth ICS with a vertical device orientation yielded the best diagnostic quality ECG tracings. There was acceptable agreement between the ECGTV and ECGAKM devices. The ECGAKM device appears to have potential to become entrenched as a basic screening tool with applicability in the field. Companion Animal Clinical Studies MSc Unrestricted 2020-11-04T15:09:48Z 2020-11-04T15:09:48Z 20/04/22 2019 Dissertation Piketh, G 2019, Application of a smartphone modulated ECG device for use in equines, MSc Dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/76762> A2020 http://hdl.handle.net/2263/76762 en © 2020 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. application/pdf University of Pretoria
spellingShingle UCTD
Application of a smartphone modulated ECG device for use in equines
title Application of a smartphone modulated ECG device for use in equines
title_full Application of a smartphone modulated ECG device for use in equines
title_fullStr Application of a smartphone modulated ECG device for use in equines
title_full_unstemmed Application of a smartphone modulated ECG device for use in equines
title_short Application of a smartphone modulated ECG device for use in equines
title_sort application of a smartphone modulated ecg device for use in equines
topic UCTD
url http://hdl.handle.net/2263/76762