Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Impact of coal quality on equipment lifetime at coal-fired power stations

Dissertation (MEng)--University of Pretoria, 2019.

Saved in:
Bibliographic Details
Other Authors: Wannenburg, Johann
Format: Thesis
Language:English
Published: University of Pretoria 2021
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613516171575296
access_status_str Open Access
author2 Wannenburg, Johann
author_browse Wannenburg, Johann
author_facet Wannenburg, Johann
collection Thesis
dc_rights_str_mv © 2020 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria.
description Dissertation (MEng)--University of Pretoria, 2019.
format Thesis
id oai:repository.up.ac.za:2263/79670
institution University of Pretoria (South Africa)
language English
last_indexed 2026-06-10T12:37:23.306Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from UPSpace — University of Pretoria Institutional Repository
publishDate 2021
publishDateRange 2021
publishDateSort 2021
publisher University of Pretoria
publisherStr University of Pretoria
record_format dspace
source_str UPSpace — University of Pretoria Institutional Repository
spelling oai:repository.up.ac.za:2263/79670 Impact of coal quality on equipment lifetime at coal-fired power stations Wannenburg, Johann u17336300@tuks.co.za Van der Westhuizen, Bernard Cornelius UCTD Coal Damage Mechanisms Equipment Life Engineering, built environment and information technology theses SDG-07 SDG-07: Affordable and clean energy Engineering, built environment and information technology theses SDG-09 SDG-09: Industry, innovation and infrastructure Engineering, built environment and information technology theses SDG-12 SDG-12: Responsible consumption and production Engineering, built environment and information technology theses SDG-13 SDG-13: Climate action Dissertation (MEng)--University of Pretoria, 2019. With the export of coal being more lucrative than selling coal to South African power producers, power station operators might consider accepting lower-quality coal. While the impact lower quality coal has on cycle efficiency is understood, the influence it has on equipment reliability and lifetime is often not understood. This study focusses on addressing the question of how different characteristics of coal influences different damage mechanisms of common power station equipment. The results are translated into a reference framework that can be used when coal quality variation is expected. The influence of coal calorific value and ash content has on air-heater element erosion was evaluated. This was accomplished by establishing a correlation between calorific value and ash content of coal from a specific colliery; this was then used to calculate the mass of fly ash and flue gas produced when burning enough coal to satisfy the boiler load. An erosion model was then used along with historical coal quality and air heater erosion history to develop and fit a model for full boiler load. The model was verified against data not used during the development of the model, and a seemingly good prediction was made when compared to the measured result. The calorific value of the coal in the model was varied for a hypothetical situation; this indicated that as calorific value decreases the erosion of air heater elements increases. The influence abrasiveness index has on mill liners was also investigated as part of this study. Historical liner ultrasonic thickness and coal abrasiveness index results were used to fit a mathematical formula. The results indicate that for the ball mills at the power station used in the case study, the abrasiveness index did not have a significant influence on the wear rate of mill liners. The relationship was established to be directly proportional to increased abrasiveness index resulting in an increased wear rate. The final two case studies that form part of this overall study were focussed on boiler temperature variations as a result of variation in coal calorific value and establishing the impact coal “hang-ups” have on the lifetime of a drum reclaimer. The first of these two case studies was completed by creating a mathematical thermo-hydraulic model of a hypothetical boiler and calculating the effect calorific value would have on the boiler temperature distribution. The results were then compared to temperature-related damage mechanisms; the comparison indicated that a variation in calorific value, whether up or down from the designed value would be negative for overall boiler health. The final case study was not completed due to the unavailability of related equipment. A full description of the envisaged study is provided. mi2025 Mechanical and Aeronautical Engineering MEng Unrestricted SDG-07: Affordable and clean energy SDG-09: Industry, innovation and infrastructure SDG-12: Responsible consumption and production SDG-13: Climate action 2021-04-22T10:33:31Z 2021-04-22T10:33:31Z 2020/09/29 2019 Dissertation Van der Westhuizen, BC 2019, Impact of coal quality on equipment lifetime at coal-fired power stations, MEng Dissertation, University of Pretoria, Pretoria, viewed yymmdd <http://hdl.handle.net/2263/79670> S2020 http://hdl.handle.net/2263/79670 en © 2020 University of Pretoria. All rights reserved. The copyright in this work vests in the University of Pretoria. No part of this work may be reproduced or transmitted in any form or by any means, without the prior written permission of the University of Pretoria. application/pdf University of Pretoria
spellingShingle UCTD
Coal
Damage Mechanisms
Equipment Life
Engineering, built environment and information technology theses SDG-07
SDG-07: Affordable and clean energy
Engineering, built environment and information technology theses SDG-09
SDG-09: Industry, innovation and infrastructure
Engineering, built environment and information technology theses SDG-12
SDG-12: Responsible consumption and production
Engineering, built environment and information technology theses SDG-13
SDG-13: Climate action
Impact of coal quality on equipment lifetime at coal-fired power stations
title Impact of coal quality on equipment lifetime at coal-fired power stations
title_full Impact of coal quality on equipment lifetime at coal-fired power stations
title_fullStr Impact of coal quality on equipment lifetime at coal-fired power stations
title_full_unstemmed Impact of coal quality on equipment lifetime at coal-fired power stations
title_short Impact of coal quality on equipment lifetime at coal-fired power stations
title_sort impact of coal quality on equipment lifetime at coal fired power stations
topic UCTD
Coal
Damage Mechanisms
Equipment Life
Engineering, built environment and information technology theses SDG-07
SDG-07: Affordable and clean energy
Engineering, built environment and information technology theses SDG-09
SDG-09: Industry, innovation and infrastructure
Engineering, built environment and information technology theses SDG-12
SDG-12: Responsible consumption and production
Engineering, built environment and information technology theses SDG-13
SDG-13: Climate action
url http://hdl.handle.net/2263/79670