One-dimensional transient cold filling simulation of a molten salt central receiver pipe

Thesis (MEng)--Stellenbosch University, 2017.

Saved in:
Bibliographic Details
Main Author: Swart, Jean Jacques
Other Authors: Hoffmann, J. E.
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2017
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867614039113203712
access_status_str Open Access
author Swart, Jean Jacques
author2 Hoffmann, J. E.
author_browse Hoffmann, J. E.
Swart, Jean Jacques
author_facet Hoffmann, J. E.
Swart, Jean Jacques
author_sort Swart, Jean Jacques
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (MEng)--Stellenbosch University, 2017.
format Thesis
id oai:scholar.sun.ac.za:10019.1/102907
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:45:41.741Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2017
publishDateRange 2017
publishDateSort 2017
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/102907 One-dimensional transient cold filling simulation of a molten salt central receiver pipe Swart, Jean Jacques Hoffmann, J. E. Stellenbosch University. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering. Cold storage Central receiver plants Numerical simulation UCTD Molten salts Solar energy Thesis (MEng)--Stellenbosch University, 2017. ENGLISH ABSTRACT: In this study, cold filling was investigated as a more efficient means of filling a receiver panel with molten salt, eliminating or reducing the need for trace heating before filling the panel. Cold filling can be defined as the filling of a receiver that is initially at a temperature below the molten salt freezing temperature. A one-dimensional numerical model was developed to enable the investigation of the molten salt characteristic response during cold filling under various conditions. The model was verified and then validated against two cold filling studies to ensure that it produces reliable results. Some differences were observed between the results produced by the model built in the current study and the validation studies, but the characteristic trends proved to correlate well. As a result, it was determined that the validation was sufficient for the investigation of the molten salt characteristic trends, as was required by this study. A test case scenario was investigated where the molten salt temperature and solidification behaviour as well as the receiver tube temperature was analysed. It was evident from the test results that the molten salt temperature decreases with distance and increases with time. A worst-case scenario, where the receiver was subjected to strong wind and rain during the filling process, was also investigated. Although possible, it is suggested that cold filling should not be used under such harsh conditions so that damage to the receiver pipes may be prevented. Additionally, the effect that changing the size of the receiver pipe has on the cold filling characteristics was determined. Larger pipes proved to have superior cold filling characteristics up to a certain pipe size. As a result, both the filling characteristics and the molten salt response during normal heated operation need to be considered when choosing the receiver pipe size. Finally, the effect that using a different salt mixture has on the filling process was considered. It was determined that HitecTM salt has superior cold filling properties compared to Solar Salt, but Solar Salt has a higher upper operating temperature and is less expensive. A plant specific analysis is, therefore, required to determine which salt type is operationally better. AFRIKAANSE OPSOMMING: In die huidige studie word koue vulling ondersoek as ‘n meer doeltreffende manier om ‘n ontvanger paneel met gesmelte sout te vul, eeder as om die paneel te voorverhit met elektriese verhitting. Koue vulling word gedefinieer as die vul van ‘n ontvangerpyp wat aanvanklik by ‘n temperatuur onder die gesmelte sout se vriespunt is. ‘n Eendimensionele numeriese model is ontwikkel om die gesmelte sout se reaksie tydens koue vulling onder verskeie toestande te ondersoek. Die model is geverifieer en toe teen twee koue vulling studies gevalideer om te verseker dat dit betroubare resultate lewer. Verskille tussen hierdie studie se resultate en die resultate van die validasie studies, is waargeneem. Die gesmelte sout se kenmerkende tendense het egter goed vergelyk met die validasie data. Die doel van die studie is om die gesmelte sout se kenmerkende tendense en reaksies onder ‘n verskeidenheid omstandighede te ondersoek. Daar is bepaal dat die validasie voldoende is vir die doeleindes van hierdie studie. ‘n Toets scenario is ondersoek om die gesmelte sout se temperatuur, snelheid en stollingsgedrag te bepaal. Daar is bevind dat die gesmelte sout se temperatuur daal oor afstand en styg met tyd. ‘n Ergste geval scenario is ook ondersoek waar die onvangerpyp aan sterk wind en swaar reën blootgestel is. Alhoewel koue vulling onder hierdie onstandighede moontlik is, word dit nie aanbeveel nie, omdat dit skade aan die ontvangerpype kan veroorsaak. Die effekwat ‘n verandering in die grootte van die pyp op die koue vulling eienskappe het, is ook bepaal. Die bevindinge dui daarop dat groter pype beter koue vulling eienskappe toon tot ‘n bepaalde pypgrootte. Die gevolgtrekking is dat beide die koue vulling eienskappe en die gesmelte sout se reaksie tydens die normale verhittingsproses in ag geneem moet word wanneer die ontvangerpype se grootte gekies word. Laastens is die impak, wat die gebruik van ‘n alternatiewe sout tipe op die koue vulling proses het, ook ondersoek. Die studie het bevind dat HitecTM sout beter koue vulling eienskappe toon as Solar Salt, maar dat Solar Salt ‘n hoër boonste bedryfstemperatuur het en goedkoper is. ‘n Aanleg spesifieke ontleding word dus benodig om die beste operasionele sout tipe te bepaal. 2017-11-19T18:40:10Z 2017-12-11T11:10:44Z 2017-11-19T18:40:10Z 2017-12-11T11:10:44Z 2017-12 Thesis http://hdl.handle.net/10019.1/102907 en_ZA Stellenbosch University 128 pages : illustrations application/pdf Stellenbosch : Stellenbosch University
spellingShingle Cold storage
Central receiver plants
Numerical simulation
UCTD
Molten salts
Solar energy
Swart, Jean Jacques
One-dimensional transient cold filling simulation of a molten salt central receiver pipe
title One-dimensional transient cold filling simulation of a molten salt central receiver pipe
title_full One-dimensional transient cold filling simulation of a molten salt central receiver pipe
title_fullStr One-dimensional transient cold filling simulation of a molten salt central receiver pipe
title_full_unstemmed One-dimensional transient cold filling simulation of a molten salt central receiver pipe
title_short One-dimensional transient cold filling simulation of a molten salt central receiver pipe
title_sort one dimensional transient cold filling simulation of a molten salt central receiver pipe
topic Cold storage
Central receiver plants
Numerical simulation
UCTD
Molten salts
Solar energy
url http://hdl.handle.net/10019.1/102907
work_keys_str_mv AT swartjeanjacques onedimensionaltransientcoldfillingsimulationofamoltensaltcentralreceiverpipe