Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Development of a dynamic tensioner device for joint gap stiffness during knee arthroplasty.

Thesis (MEng)--Stellenbosch University, 2018.

Saved in:
Bibliographic Details
Main Author: Wium, Daniel Jacobus
Other Authors: Muller, Jacobus Hendrik
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2018
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867614010386415616
access_status_str Open Access
author Wium, Daniel Jacobus
author2 Muller, Jacobus Hendrik
author_browse Muller, Jacobus Hendrik
Wium, Daniel Jacobus
author_facet Muller, Jacobus Hendrik
Wium, Daniel Jacobus
author_sort Wium, Daniel Jacobus
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (MEng)--Stellenbosch University, 2018.
format Thesis
id oai:scholar.sun.ac.za:10019.1/103784
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:45:13.990Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2018
publishDateRange 2018
publishDateSort 2018
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/103784 Development of a dynamic tensioner device for joint gap stiffness during knee arthroplasty. Wium, Daniel Jacobus Muller, Jacobus Hendrik Stellenbosch University. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering. Arthroplasty Joints -- Surgery Tibiofemoral force UCTD Total knee replacement Thesis (MEng)--Stellenbosch University, 2018. ENGLISH ABSTRACT: Correct knee alignment and soft tissue tensions can relieve pain, improve knee function and increase the durability of the prosthesis after knee arthroplasty. Knee alignment and soft tissue tensions relate to the joint gap stiffness. The joint gap stiffness is a measure of the tension in the ligaments and the distance between the femur and the tibia. The joint gap stiffness of the knee is typically assessed with the knee in 0° and 90° knee flexion. Guidelines for the tension of the ligaments and the distance between the femur and the tibia have not yet been defined for knee flexion between these angles. The aim of this study is to provide a proof of concept for a dynamic knee tensioning device capable of measuring the joint gap stiffness at all angles between 0° and 90° knee flexion during unicompartmental knee arthroplasty. In this study, two prototypes were developed which quantify the joint gap stiffness in terms of the tibiofemoral force and the gap distance. The prototypes are capable of either measuring the tibiofemoral force at a constant gap distance or measuring the gap distance at a constant distraction force. Three in-vitro tests were conducted in which the prototypes were used to measure the joint gap stiffness of cadaver knees. The joint gap stiffness was measured in the native knee (intact femur) as well as in the resurfaced knee. The results have proven that the knee tensioners developed in this study can provide insight into certain characteristics of the knee, which include knee stiffness, spatial geometry, and articulating surface geometry of either the medial or the lateral compartments. The knee tensioners assess the outcome of soft tissue balancing on a quantitative level which can be correlated to postoperative results. This may lead to the standardisation of soft tissue balancing. The knee tensioners developed in this study provide a concept for the design of a dynamic knee tensioner to be used during clinical unicompartmental knee arthroplasty as well as in clinical total knee arthroplasty. AFRIKAANSE OPSOMMING: Korrekte knie-belyning en sagteweefsel-spanning kan die funksie van ‘n knie verbeter en die duursaamheid van ‘n prostese verleng na afloop van ‘n knievervangingsoperasie. Knie-belyning en sagteweefsel-spanning hou verband met die kniegewrig-gaping-styfheid. Die kniegewrig-gaping-styfheid is ‘n funksie van die spanning in die knieligamente en ‘n funksie van die afstand tussen die femur en die tibia. Die kniegewrig-gaping-styfheid word tipies geassesseer met die knie in 0° en 90° fleksie. Daar bestaan nog nie riglyne om die spanning in die knieligamente óf die afstand tussen die femur en die tibia tussen hierdie hoeke van knie-fleksie te bepaal nie. Die doel van hierdie studie is om ‘n konsepbewys te lewer vir ‘n nuwe dinamiese knietoestel wat die gewrig-gaping-styfheid kan meet by alle hoeke van knie-fleksie tussen 0° en 90° tydens ‘n halwe knievervangingsoperasie. In hierdie studie is twee prototipes ontwikkel wat die kniegewrig-gaping-styfheid kwantifiseer in terme van die spanning in die knieligamente en die afstand tussen die femur en die tibia. Die prototipes kan óf die tibiofemorale krag meet met ‘n konstante gaping-afstand óf die gaping-afstand meet met ‘n konstante tibiofemorale krag. Drie in-vitro toetse, waartydens die gewrig-gaping-styfheid van kadawer knieë gemeet is, is uitgevoer. Die gewrig-gaping-styfheid is gemeet in die oorspronklik knie met die ongeskonde femur en ook in die knie waarby prostetiese femurs ingevoeg is. Die in-vitro toetse het insiggewende resultate rakende die styfheid van die knie, die geometrie van die knie ruimte, en die geometrie van die kontakoppervlakte van die bene in óf die laterale óf mediale kompartemente gelewer. Die knietoestelle assesseer die uitkoms van sagteweefsel-balansering tydens ‘n knievervangingsoperasie op ‘n kwantitatiewe vlak wat met resultate verkry na ‘n operasie gekorreleer kan word. Dit mag lei tot die standaardisering van sagteweefsel-balansering. Die knietoestelle in hierdie studie lewer ‘n konsep vir die ontwerp van ‘n dinamiese knietoestel wat in ‘n kliniese halwe knievervangingsoperasie en in ‘n kliniese totale knievervangingsoperasie gebruik kan word. 2018-02-28T19:31:40Z 2018-04-09T07:09:27Z 2018-02-28T19:31:40Z 2018-04-09T07:09:27Z 2018-03 Thesis http://hdl.handle.net/10019.1/103784 en_ZA Stellenbosch University 145 pages : illustrations application/pdf Stellenbosch : Stellenbosch University
spellingShingle Arthroplasty
Joints -- Surgery
Tibiofemoral force
UCTD
Total knee replacement
Wium, Daniel Jacobus
Development of a dynamic tensioner device for joint gap stiffness during knee arthroplasty.
title Development of a dynamic tensioner device for joint gap stiffness during knee arthroplasty.
title_full Development of a dynamic tensioner device for joint gap stiffness during knee arthroplasty.
title_fullStr Development of a dynamic tensioner device for joint gap stiffness during knee arthroplasty.
title_full_unstemmed Development of a dynamic tensioner device for joint gap stiffness during knee arthroplasty.
title_short Development of a dynamic tensioner device for joint gap stiffness during knee arthroplasty.
title_sort development of a dynamic tensioner device for joint gap stiffness during knee arthroplasty
topic Arthroplasty
Joints -- Surgery
Tibiofemoral force
UCTD
Total knee replacement
url http://hdl.handle.net/10019.1/103784
work_keys_str_mv AT wiumdanieljacobus developmentofadynamictensionerdeviceforjointgapstiffnessduringkneearthroplasty