Thesis (PhD (Mechanical and Mechatronic Engineering)--University of Stellenbosch, 1990.
| Main Authors: | , |
|---|---|
| Other Authors: | |
| Format: | Thesis |
| Language: | en_ZA |
| Published: |
Stellenbosch : University of Stellenbosch
2011
|
| Subjects: | |
| Tags: |
No Tags, Be the first to tag this record!
|
| _version_ | 1867613792524828672 |
|---|---|
| access_status_str | Open Access |
| author | Venter, Sarel Jacobus Kroger, D. G. |
| author2 | University of Stellenbosch. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering |
| author_browse | Kroger, D. G. University of Stellenbosch. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering Venter, Sarel Jacobus |
| author_facet | University of Stellenbosch. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering Venter, Sarel Jacobus Kroger, D. G. |
| author_sort | Venter, Sarel Jacobus |
| collection | Thesis |
| dc_rights_str_mv | University of Stellenbosch |
| description | Thesis (PhD (Mechanical and Mechatronic Engineering)--University of Stellenbosch, 1990. |
| format | Thesis |
| id | oai:scholar.sun.ac.za:10019.1/15625 |
| institution | Stellenbosch University (South Africa) |
| language | en_ZA |
| last_indexed | 2026-06-10T12:41:46.856Z |
| license_str | Other — see source repository |
| provenance_str_mv | Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository |
| publishDate | 2011 |
| publishDateRange | 2011 |
| publishDateSort | 2011 |
| publisher | Stellenbosch : University of Stellenbosch |
| publisherStr | Stellenbosch : University of Stellenbosch |
| record_format | dspace |
| source_str | SUNScholar — Stellenbosch University Repository |
| spelling | oai:scholar.sun.ac.za:10019.1/15625 The effectiveness of axial flow fans in a-frame plenums Venter, Sarel Jacobus Kroger, D. G. University of Stellenbosch. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering Fans (Machinery) -- Performance Blades Heat exchangers Air flow Air conditioning Dissertations -- Mechanical engineering Theses -- Mechanical engineering Thesis (PhD (Mechanical and Mechatronic Engineering)--University of Stellenbosch, 1990. ENGLISH ABSTRACT: The ultimate goal of this project is to ensure a better understanding of the governing mechanisms present when flow distorting components are installed in close proximity of an axial flow fan. The effect of different parameters on the operation of axial flow fans is investigated. These parameters are divided into flow enhancing and flow reduction effects. The performance of an axial flow fan can be enhanced by changing the tip clearance, by adding a solid disc to the hub of the fan or by varying the number of fan blades. Flow reductions are caused by components such as inlet grids, walkways and their supporting structures, heat exchangers and windwalls. The effects of flow enhancing components are measured and compared to the results of other authors. The sensitivity of these effects to parameters such as the type of fan rotor and the specific system in which the rotor is installed is highlighted. The system effect (the interaction between the fan rotor and flow resistances in close proximity of each other) of individual components, as well as the combination of different components, is predicted both theoretically and experimentally. These predictions are compared to measured data relevant to the components in an installation where the system effects are present. The results are correlated to the kinetic energy flux coefficient of the flow at different locations within the installation. Experimental data obtained from a full scale unit (inlet shroud diameter of 9,216 m) are used to compare to scaled data from the model (inlet shroud diameter of 1,542 m). The hub to tip ratio of the axial flow fans investigated is 0,15. The most important conclusions are that the performance of the type of axial flow fan under investigation can be improved by reducing its tip clearance and by installing a solid disc to the downstream side of the rotor. An increase in the number of blades of the fan leads to only marginal improvements in the fan performance. The overall performance of the system can also be improved by removing some of the flow resisting components, or by changing their relative positions. All these conclusions are based on the assumption that the power input to the fan rotor remains constant. AFRIKAANSE OPSOMMING: Die uiteindelike doel van hierdie projek is om te verseker dat die beherende meganismes wat teenwoordig is wanneer vloeiversteurende komponente in die nabyheid van 'n aksiaalwaaier geinstalleer word, beter verstaan word. Die effek van verskillende parameters op die werkverrigting van aksiaalwaaiers word ondersoek. Hierdie parameters word verdeel in vloeiverbeterings- en vloeiverminderingseffekte. Die werkverrigting van 'n aksiaalwaaier kan verbeter word deur die lempuntspeling te verstel, deur 'n soliede skyf aan die naaf van die waaierrotor te installeer, of deur die aantal lemme te verander. Die vloeiverminderings word veroorsaak deur inlaatsiwwe, loopvlakke en hul ondersteuningsstrukture, warmteruilers en windwande. Die effekte van vloeiverbeteringskomponente word gemeet en vergelyk met die resultate van ander outeurs. Die sensitiwiteit van hierdie effekte op parameters soos die tipe rotor en die spesifieke stelsel waarin die rotor geinstalleer is, word uitgelig. Die stelseleffek (die interaksie tussen die rotor van die waaier en vloei weerstande wat naby mekaar geinstalleer is) van individuele, sowel as 'n kombinasie van verskillende komponente, word teoreties en eksperimenteel voorspel. Hierdie voorspellings word dan vergelyk met eksperimentele data wat van toepassing is op die komponente in 'n installasie waar stelseleffekte voorkom. Die resultate word gekoppel aan die kinetiese energievloedkoeffisient van die vloei by verskillende posisies binne die installasie. Eksperimentele data, verkry vanaf 'n volskaaleenheid (inlaatmondstukdiameter van 9,216 m), word met die geskaleerde data van die model (inlaatmondstukdiameter van 1,542 m) vcrgelyk. Die naaf- tot hulsverhouding van die aksiaalwaaiers wat ondersoek word is 0,15. Die belangrikste gevolgtrekkings is dat die werkverrigting van die tipe aksiaalwaaier wat ondersoek word verbeter kan word deur die lempuntspeling te verminder en deur 'n soliede skyf te installeer by die stroomaf kant van die rotor. 'n Toename in die aantal lemme van die waaier lei slegs tot marginale verbeterings in die werkverrigting van die waaier. Die totale werkverrigting van die stesel kan ook verbeter word deur sommige vloeiweerstandskomponente te verwyder, of deur hulle relatiewe posisies te verander. Al hierdie gevolgtrekkings is gebasseer op die aanname dat die drywingsinset na die waaierrotor konstant bly. 260 leaves printed single pages, preliminary pages i-xxi and numbered pages Chapter 1/1.1-1.3, Chapter 2/2.1-2.17, Chapter 3/3.1.1-3.10, Chapter 4/4.1-4.18, Chapter 5/5.1-5.3, References pages R.1-R.7, Appendix A pages A.1-A.34, Appendix B pages B.1-B.34, Appendix C pages C.1-C.26, Appendix D pages D.1-D.16, Appendix E pages E.1-E.30, Appendix F pages F.1-F.39. Includes bibliography, list of tables, figures and symbols. Doctoral 2011-07-20T06:59:35Z 2011-07-20T06:59:35Z 1990-03 Thesis http://hdl.handle.net/10019.1/15625 en_ZA University of Stellenbosch application/pdf Stellenbosch : University of Stellenbosch |
| spellingShingle | Fans (Machinery) -- Performance Blades Heat exchangers Air flow Air conditioning Dissertations -- Mechanical engineering Theses -- Mechanical engineering Venter, Sarel Jacobus Kroger, D. G. The effectiveness of axial flow fans in a-frame plenums |
| title | The effectiveness of axial flow fans in a-frame plenums |
| title_full | The effectiveness of axial flow fans in a-frame plenums |
| title_fullStr | The effectiveness of axial flow fans in a-frame plenums |
| title_full_unstemmed | The effectiveness of axial flow fans in a-frame plenums |
| title_short | The effectiveness of axial flow fans in a-frame plenums |
| title_sort | effectiveness of axial flow fans in a frame plenums |
| topic | Fans (Machinery) -- Performance Blades Heat exchangers Air flow Air conditioning Dissertations -- Mechanical engineering Theses -- Mechanical engineering |