Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Performance evaluation of wet-cooling tower fills with computational fluid dynamics

Thesis (MScEng)--Stellenbosch University, 2012.

Saved in:
Bibliographic Details
Main Author: Gudmundsson, Yngvi
Other Authors: Reuter, H. C. R.
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2012
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867614038004858880
access_status_str Open Access
author Gudmundsson, Yngvi
author2 Reuter, H. C. R.
author_browse Gudmundsson, Yngvi
Reuter, H. C. R.
author_facet Reuter, H. C. R.
Gudmundsson, Yngvi
author_sort Gudmundsson, Yngvi
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (MScEng)--Stellenbosch University, 2012.
format Thesis
id oai:scholar.sun.ac.za:10019.1/19908
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:45:40.774Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2012
publishDateRange 2012
publishDateSort 2012
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/19908 Performance evaluation of wet-cooling tower fills with computational fluid dynamics Gudmundsson, Yngvi Reuter, H. C. R. Stellenbosch University. Faculty of Engineering. Dept. of Mechanical & Mechatronic Engineering. Poppe model Dissertations -- Mechanical engineering Theses -- Mechanical engineering Wet cooling towers Computational fluid dynamics Heat mass transfers Merkel model Reuter model Thesis (MScEng)--Stellenbosch University, 2012. ENGLISH ABSTRACT: A wet-cooling tower fill performance evaluation model developed by Reuter is derived in Cartesian coordinates for a rectangular cooling tower and compared to cross- and counterflow Merkel, e-NTU and Poppe models. The models are compared by applying them to a range of experimental data measured in the cross- and counterflow wet-cooling tower test facility at Stellenbosch University. The Reuter model is found to effectively give the same results as the Poppe method for cross- and counterflow fill configuration as well as the Merkel and e-NTU method if the assumptions as made by Merkel are implemented. A second order upwind discretization method is applied to the Reuter model for increased accuracy and compared to solution methods generally used to solve cross- and counterflow Merkel and Poppe models. First order methods used to solve the Reuter model and crossflow Merkel and Poppe models are found to need cell sizes four times smaller than the second order method to obtain the same results. The Reuter model is successfully implemented in two- and three-dimensional ANSYS-Fluent® CFD models for under- and supersaturated air. Heat and mass transfer in the fill area is simulated with a user defined function that employs a second order upwind method. The two dimensional ANSYS-Fluent® model is verified by means of a programmed numerical model for crossflow, counterflow and cross-counterflow. AFRIKAANSE OPSOMMING: ‘n Natkoeltoring model vir die evaluering van pakkings werkverrigting, wat deur Reuter ontwikkel is, word in Kartesiese koördinate afgelei vir ‘n reghoekige koeltoring en word vergelyk met kruis- en teenvloei Merkel, e-NTU en Poppe modelle. Die verskillende modelle word vergelyk deur hulle op ‘n reeks eksperimentele data toe te pas wat in die kruis- en teenvloei natkoeltoring toetsfasiliteit by die Universiteit van Stellenbosch gemeet is. Dit is bevind dat die Reuter model effektief dieselfde resultate gee as die Poppe model vir kruis- en teenvloei pakkingskonfigurasies sowel as die Merkel en e-NTU metode, indien dieselfde aannames wat deur Merkel gemaak is geїmplementeer word. ‘n Tweede orde “upwind” metode word op die Reuter model toegepas vir hoër akkuraatheid en word vergelyk met oplossingsmetodes wat gewoonlik gebruik word om kruis- en teenvloei Merkel en Poppe modelle op te los. Eerste orde metodes wat gebruik is om die Reuter model en kruisvloei Merkel en Poppe modelle op te los benodig rooster selle wat vier keer kleiner is as vir tweede orde metodes om dieselfde resultaat te verkry. Die Reuter model is suksesvol in twee- en driedimensionele ANSYS-Fluent® BVD (“CFD”) modelle geїmplementeer vir on- en oorversadigde lug. Warmte- en massaoordrag in die pakkingsgebied word gesimuleer mbv ‘n gebruiker gedefinieerde funksie (“user defined function”) wat van ‘n tweede orde numeriese metode gebruik maak. Die tweedimensionele ANSYS-Fluent® model word m.b.v. ‘n geprogrameerde numeriese model bevestig vir kruis-, teen- en kruis-teenvloei. 2012-03-13T11:12:37Z 2012-03-30T10:23:28Z 2012-03-13T11:12:37Z 2012-03-30T10:23:28Z 2012-03 Thesis http://hdl.handle.net/10019.1/19908 en_ZA Stellenbosch University 110 p. : ill. application/pdf Stellenbosch : Stellenbosch University
spellingShingle Poppe model
Dissertations -- Mechanical engineering
Theses -- Mechanical engineering
Wet cooling towers
Computational fluid dynamics
Heat mass transfers
Merkel model
Reuter model
Gudmundsson, Yngvi
Performance evaluation of wet-cooling tower fills with computational fluid dynamics
title Performance evaluation of wet-cooling tower fills with computational fluid dynamics
title_full Performance evaluation of wet-cooling tower fills with computational fluid dynamics
title_fullStr Performance evaluation of wet-cooling tower fills with computational fluid dynamics
title_full_unstemmed Performance evaluation of wet-cooling tower fills with computational fluid dynamics
title_short Performance evaluation of wet-cooling tower fills with computational fluid dynamics
title_sort performance evaluation of wet cooling tower fills with computational fluid dynamics
topic Poppe model
Dissertations -- Mechanical engineering
Theses -- Mechanical engineering
Wet cooling towers
Computational fluid dynamics
Heat mass transfers
Merkel model
Reuter model
url http://hdl.handle.net/10019.1/19908
work_keys_str_mv AT gudmundssonyngvi performanceevaluationofwetcoolingtowerfillswithcomputationalfluiddynamics