Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Structural design of a stent for a percutaneous aortic heart valve

Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2009.

Saved in:
Bibliographic Details
Main Author: Esterhuyse, Anton
Other Authors: Scheffer, C.
Format: Thesis
Language:English
Published: Stellenbosch : University of Stellenbosch 2009
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867614115768303616
access_status_str Open Access
author Esterhuyse, Anton
author2 Scheffer, C.
author_browse Esterhuyse, Anton
Scheffer, C.
author_facet Scheffer, C.
Esterhuyse, Anton
author_sort Esterhuyse, Anton
collection Thesis
dc_rights_str_mv University of Stellenbosch
description Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2009.
format Thesis
id oai:scholar.sun.ac.za:10019.1/2706
institution Stellenbosch University (South Africa)
language English
last_indexed 2026-06-10T12:46:55.034Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2009
publishDateRange 2009
publishDateSort 2009
publisher Stellenbosch : University of Stellenbosch
publisherStr Stellenbosch : University of Stellenbosch
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/2706 Structural design of a stent for a percutaneous aortic heart valve Esterhuyse, Anton Scheffer, C. Van der Westhuizen, K. University of Stellenbosch. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering. Interventional cardiology Dissertations -- Mechanical engineering Theses -- Mechanical engineering Heart -- Surgery Stents (Surgery) Aortic valve Mechanical and Mechatronic Engineering Thesis (MScEng (Mechanical and Mechatronic Engineering))--University of Stellenbosch, 2009. Elderly patients suffering from aortic valvular dysfunction are often denied aortic valve replacement due to the fact that they are classified as too old and fragile to handle the physical stress of open-heart surgery and cardio-pulmonary bypass. There exists a need for an alternative solution which places less physical stress on the body. The development of a percutaneous aortic heart valve (PAHV), which may be implanted through a minimally invasive procedure, will provide a solution to old and fragile patients who otherwise have a very limited life expectancy. The development of such a device entails a costly and time-consuming process which involves a number of phases, including a prototype development phase, an in-vitro testing phase, an animal trial phase and a human trial phase. This thesis focuses on the design and analysis of the stent component for a PAHV, suitable for implantation in sheep (animal trial phase). The process of developing a first prototype, involved an analysis of the stent design requirements. This analysis was followed by a concept generation phase as well as comprehensive finite element (FE) analyses of the most promising concepts. The objective of the FE analyses was to determine the effects of a variation in strut width on the performance characteristics of the concepts. Based on the results of the FE analyses, final geometries were selected for each of the two most promising concepts. Subsequent to the selection of the final geometries, a number of prototypes were manufactured. The prototypes were subjected to an electro-polishing process. An experimental analysis was also conducted on the prototypes to evaluate the accuracy of the (FE) simulations as well as the actual performance of the stent prototypes. The results of the FE analyses and experimental analyses indicated that strut width had a substantial influence on the parameters that were defined to characterise stent performance. The results of the analyses also highlighted the advantages and disadvantages of each concept and aided in identifying the concept that would be most suitable for the required application. Limitations of the study were identified and recommendations were made to assist the continued research and development of the device. 2009-02-17T11:18:35Z 2010-06-01T08:56:16Z 2009-02-17T11:18:35Z 2010-06-01T08:56:16Z 2009-03 Thesis http://hdl.handle.net/10019.1/2706 en University of Stellenbosch application/pdf application/pdf Stellenbosch : University of Stellenbosch
spellingShingle Interventional cardiology
Dissertations -- Mechanical engineering
Theses -- Mechanical engineering
Heart -- Surgery
Stents (Surgery)
Aortic valve
Mechanical and Mechatronic Engineering
Esterhuyse, Anton
Structural design of a stent for a percutaneous aortic heart valve
title Structural design of a stent for a percutaneous aortic heart valve
title_full Structural design of a stent for a percutaneous aortic heart valve
title_fullStr Structural design of a stent for a percutaneous aortic heart valve
title_full_unstemmed Structural design of a stent for a percutaneous aortic heart valve
title_short Structural design of a stent for a percutaneous aortic heart valve
title_sort structural design of a stent for a percutaneous aortic heart valve
topic Interventional cardiology
Dissertations -- Mechanical engineering
Theses -- Mechanical engineering
Heart -- Surgery
Stents (Surgery)
Aortic valve
Mechanical and Mechatronic Engineering
url http://hdl.handle.net/10019.1/2706
work_keys_str_mv AT esterhuyseanton structuraldesignofastentforapercutaneousaorticheartvalve