Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Performance characteristics of expanded metal cooling tower fill

Thesis (M.Ing.) -- University of Stellenbosch, 1998.

Saved in:
Bibliographic Details
Main Author: Baard, Tertius Willem
Other Authors: Stellenbosch University. Faculty of . Dept. of .
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2012
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613976160894976
access_status_str Open Access
author Baard, Tertius Willem
author2 Stellenbosch University. Faculty of . Dept. of .
author_browse Baard, Tertius Willem
Stellenbosch University. Faculty of . Dept. of .
author_facet Stellenbosch University. Faculty of . Dept. of .
Baard, Tertius Willem
author_sort Baard, Tertius Willem
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (M.Ing.) -- University of Stellenbosch, 1998.
format Thesis
id oai:scholar.sun.ac.za:10019.1/51014
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:44:41.678Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2012
publishDateRange 2012
publishDateSort 2012
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/51014 Performance characteristics of expanded metal cooling tower fill Baard, Tertius Willem Stellenbosch University. Faculty of . Dept. of . Cooling towers Expanded metal Counterflow cooling tower fill Splash fill simulation Merkel and Poppe model Induced draught cooling tower simulation Dissertations -- Mechanical engineering Thesis (M.Ing.) -- University of Stellenbosch, 1998. Full text to be digitised and attached to bibliographic record. 2012-08-27T11:34:17Z 2012-08-27T11:34:17Z 1998 Thesis http://hdl.handle.net/10019.1/51014 en_ZA Stellenbosch University 1 v. (various pagings) : ill. Stellenbosch : Stellenbosch University
spellingShingle Cooling towers
Expanded metal
Counterflow cooling tower fill
Splash fill simulation
Merkel and Poppe model
Induced draught cooling tower simulation
Dissertations -- Mechanical engineering
Baard, Tertius Willem
Performance characteristics of expanded metal cooling tower fill
title Performance characteristics of expanded metal cooling tower fill
title_full Performance characteristics of expanded metal cooling tower fill
title_fullStr Performance characteristics of expanded metal cooling tower fill
title_full_unstemmed Performance characteristics of expanded metal cooling tower fill
title_short Performance characteristics of expanded metal cooling tower fill
title_sort performance characteristics of expanded metal cooling tower fill
topic Cooling towers
Expanded metal
Counterflow cooling tower fill
Splash fill simulation
Merkel and Poppe model
Induced draught cooling tower simulation
Dissertations -- Mechanical engineering
url http://hdl.handle.net/10019.1/51014
work_keys_str_mv AT baardtertiuswillem performancecharacteristicsofexpandedmetalcoolingtowerfill