Full Text Available
Note: Clicking the button above will open the full text document at the original institutional repository in a new window.
Thesis (MEng)--University of Stellenbosch, 2001.
| Main Author: | |
|---|---|
| Other Authors: | |
| Format: | Thesis |
| Language: | en_ZA |
| Published: |
Stellenbosch : Stellenbosch University
2012
|
| Subjects: | |
| Tags: |
No Tags, Be the first to tag this record!
|
| _version_ | 1867613961826861056 |
|---|---|
| access_status_str | Open Access |
| author | Dirkse van Schalkwyk, W. J. |
| author2 | Holtzhausen, J. P. |
| author_browse | Dirkse van Schalkwyk, W. J. Holtzhausen, J. P. |
| author_facet | Holtzhausen, J. P. Dirkse van Schalkwyk, W. J. |
| author_sort | Dirkse van Schalkwyk, W. J. |
| collection | Thesis |
| dc_rights_str_mv | Stellenbosch University |
| description | Thesis (MEng)--University of Stellenbosch, 2001. |
| format | Thesis |
| id | oai:scholar.sun.ac.za:10019.1/52553 |
| institution | Stellenbosch University (South Africa) |
| language | en_ZA |
| last_indexed | 2026-06-10T12:44:27.789Z |
| license_str | Other — see source repository |
| provenance_str_mv | Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository |
| publishDate | 2012 |
| publishDateRange | 2012 |
| publishDateSort | 2012 |
| publisher | Stellenbosch : Stellenbosch University |
| publisherStr | Stellenbosch : Stellenbosch University |
| record_format | dspace |
| source_str | SUNScholar — Stellenbosch University Repository |
| spelling | oai:scholar.sun.ac.za:10019.1/52553 The placing of line surge arresters and fuses on 11 and 12 kV lines to protect equipment against lightning Dirkse van Schalkwyk, W. J. Holtzhausen, J. P. Stellenbosch University. Faculty of Engineering. Dept. of Electrical and Electronic Engineering. Electric power distribution Electric lines Lightning Dissertations -- Electronic engineering Distribution lines Theses -- Electronic engineering Thesis (MEng)--University of Stellenbosch, 2001. ENGLISH ABSTRACT: Unshielded distribution lines has a poor performance during lightning activity. Lightning initiates flashovers between the phases and earth and causes line breakers to trip several times during a lightning storm. In addition equipment like fuses, surge arresters and transformers are damaged by lightning and cause in some cases long power interruptions to customers. The application of line surge arresters on distribution lines is a solution that is implemented worldwide to limit the lightning related problems. This thesis investigated using line surge arresters in conjunction with bushing-mount fuses to decrease nuisance fusing and transformer damage during lightning activity. Two new pieces of equipment (dropout surge arresters and transformer bushingmount fuses) were developed and strategically placed on 4 different distribution lines. Equipment failures decreased by 90 % while financially the project had an excellent return on investment. AFRIKAANSE OPSOMMING: Distribusie lyne sonder skermdrade presteer swak gedurende weerlig aktiwiteit. Weerlig veroorsaak oorvonking tussen fases en aard geleiers wat lei tot breker klinke. Transformators, sekerings, stuwingsafleiers en ander toerusting word ook deur weerlig beskadig en veroorsaak in sommige gevalle lang toevoer onderbrekings. Installering van lyn stuwingsafleiers op distribusielyne is 'n metode wat wêreldwyd gebruik word om oorvonking en weerligskade te beperk. Hierdie tesis ondersoek die installering van lyn stuwingsafleiers en deurvoerder gemonteerde sekerings om transformator skade en onnodige blaas van sekerings te beperk tydens weerlig aktiwiteit. Nuwe toerusting (uitval stuwingsafleiers en transformator deurvoerder gemonteerde sekerings) was ontwikkel en strategies op 4 verskillende distribusie lyne geïnstalleer. 'n Negentig persent vermindering in toerusting beskadiging is behaal terwyl die projek finansiël 'n goeie opbrengs op belegging meegebring het. 2012-08-27T11:35:03Z 2012-08-27T11:35:03Z 2001-03 Thesis http://hdl.handle.net/10019.1/52553 en_ZA Stellenbosch University 1 v. (various pagings) : ill. application/pdf Stellenbosch : Stellenbosch University |
| spellingShingle | Electric power distribution Electric lines Lightning Dissertations -- Electronic engineering Distribution lines Theses -- Electronic engineering Dirkse van Schalkwyk, W. J. The placing of line surge arresters and fuses on 11 and 12 kV lines to protect equipment against lightning |
| title | The placing of line surge arresters and fuses on 11 and 12 kV lines to protect equipment against lightning |
| title_full | The placing of line surge arresters and fuses on 11 and 12 kV lines to protect equipment against lightning |
| title_fullStr | The placing of line surge arresters and fuses on 11 and 12 kV lines to protect equipment against lightning |
| title_full_unstemmed | The placing of line surge arresters and fuses on 11 and 12 kV lines to protect equipment against lightning |
| title_short | The placing of line surge arresters and fuses on 11 and 12 kV lines to protect equipment against lightning |
| title_sort | placing of line surge arresters and fuses on 11 and 12 kv lines to protect equipment against lightning |
| topic | Electric power distribution Electric lines Lightning Dissertations -- Electronic engineering Distribution lines Theses -- Electronic engineering |
| url | http://hdl.handle.net/10019.1/52553 |
| work_keys_str_mv | AT dirksevanschalkwykwj theplacingoflinesurgearrestersandfuseson11and12kvlinestoprotectequipmentagainstlightning AT dirksevanschalkwykwj placingoflinesurgearrestersandfuseson11and12kvlinestoprotectequipmentagainstlightning |