Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Wideband modelling of capacitive voltage sensors for open-air transmission line applications

Thesis (PhD)--University of Stellenbosch, 2002.

Saved in:
Bibliographic Details
Main Author: Schilder, Melanie
Other Authors: Vermeulen, H. J.
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2012
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867614031387295744
access_status_str Open Access
author Schilder, Melanie
author2 Vermeulen, H. J.
author_browse Schilder, Melanie
Vermeulen, H. J.
author_facet Vermeulen, H. J.
Schilder, Melanie
author_sort Schilder, Melanie
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (PhD)--University of Stellenbosch, 2002.
format Thesis
id oai:scholar.sun.ac.za:10019.1/53222
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:45:33.890Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2012
publishDateRange 2012
publishDateSort 2012
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/53222 Wideband modelling of capacitive voltage sensors for open-air transmission line applications Schilder, Melanie Vermeulen, H. J. Stellenbosch University. Faculty of Engineering. Dept. of Electrical and Electronic Engineering. Electric lines Capacitance meters Dissertations -- Electrical engineering Theses -- Electrical engineering Thesis (PhD)--University of Stellenbosch, 2002. ENGLISH ABSTRACT: This dissertation considers the wideband modelling of capacitive voltage sensors for open-air transmission line applications. Two novel topologies were introduced, namely a differential parallel plate sensor with a floating faraday cage for the interface instrumentation and a coaxial sensor mounted around the earth conductor with a faraday cage connected to the earth conductor. The modelling and analysis procedures included the derivation of equivalent circuit models in order to simulate the calibration factor, the loading effect of the interface instrumentation and the effect of leakage to ground, both in the time- and frequency domain. In order to obtain a flat frequency response from very low frequencies (less than 5 Hz) to very high frequencies (several MHz) it is important that the interface instrumentation have a high input impedance and galvanic isolation be maintained. This was achieved by developing interface instrumentation with a fibre-optic link operated from battery power. The instrumentation represents a fairly unique approach in that the data is digitised before transmission across the serial fibre-optical link, where-as conventional interfaces use analogue optical technology. Despite the added complexity and high power requirements introduced by the digitising process, the improved versatility is expected to yield a superior interface solution. The instrumentation has a bandwidth of approximately 6 MHz, with an optional anti-aliasing filter at 1 MHz. Special consideration should be given to the support structure as any unbalanced leakage to ground will introduce variations in the frequency response towards the low-frequency end. Leakage of a 100 MQ was found to influence the frequency response of the circuit up to frequencies of 1 kHz. Extensive simulation studies were conducted to obtain qualitative and quantitative insight into the differential sensor topology and the associated electric fields. The improvement of a differential plate sensor over the traditional single element plate sensor was demonstrated using twodimensional simulations. Further simulations with a three-dimensional package showed that the two-dimensional simulations are insufficient, because the boundary conditions and end effects have a great influence on the calibration factor of the sensor. Extensive laboratory tests were also undertaken to evaluate the sensor topology as well as the effects of the interface instrumentation and leakage to ground. Excellent correlation were found between the measured and simulated waveforms, both in the time- and frequency domains regarding the calibration factor as well as the added poles or zeros at low frequencies. It can therefore be deduced that a valid circuit model was suggested for these sensor topologies in the frequency range from 10 Hz to 1 MHz. Keywords: Capacitive sensors, Open-air voltage sensors AFRIKAANSE OPSOMMING: Hierdie verhandeling beskou die wyeband modellering van kapasitiewe spanningsensors vir opelug transmissie lyn toepassings. Twee oorspronklike topologieë is voorgestel, naamlik 'n differensiële parallel plaat sensor met 'n aparte faraday hok vir die koppelvlak instrumentasie en 'n koaksiale sensor wat rondom die aardgeleier monteer word met die faraday hok ook aan die aardgeleier gekoppel. Die modellerings en analise prosedures het ingesluit die afleiding van ekwivalente stroombaanmodelle vir simulasie van die kalibrasiefaktor asook die belasingseffek van die koppelvlak instrumentasie en lekweerstand na grond in beide die tyd- en frekwensie gebiede. Om 'n plat frekwensieweergawe te verkry vanaf baie lae frekwensies (laer as 5 Hz) tot by baie hoë frekwensies Cn paar MHz), is dit belangrik dat die koppelvlak instrumentasie 'n hoë intreeimpedansie het en galvaniese isolasie verseker word. Dit was bereik deur koppelvlak instrumentasie te ontwikkel met 'n optiese vesel koppeling wat met battery krag aangedryf word. Die instrumentasie verskaf 'n redelik unieke aanslag in die opsig dat die data gemonster word voordat dit oor die seriële optiese vesel skakel gestuur word, terwyl konvensionele koppelvlakke analoog optiese tegnologie gebruik. Ten spyte van die toegevoegde kompleksiteit en hoë drywingsvereistes van die versyferingsproses, het die instrumentasie se veelsydigheid toegeneem tot die mate dat dit as 'n beter koppelvlak oplossing beskou word. Die instrumentasie het 'n bandwydte van ongeveer 6 MHz, met 'n opsionele teen-vou filter by 1 MHz. Die ondersteuningstruktuur is van besondere belang aangesien enige ongebalanseerde lekweerstand na grond afwykings in die frekwensieweergawe sal veroorsaak aan die lae frekwensie kant. Lekweerstand van 100 MQ sal die frekwensieweergawe beïvloed tot by ongeveer 1 kHz. Uitgebreide simulasies is gedoen om kwalitatiewe en kwantitatiewe insig in die differensiële sensor topologie en die geassosieerde elektriese velde te verkry. Die verbetering van 'n differensiële parallel plaat sensor in vergelyking met die tradisionele enkel element plaat sensor is demonstreer met twee-dimensionele simulasies. Verdere simulasies met 'n drie-dimensionele pakket het gewys dat die twee- dimensionele simulasies onvoldoende is aangesien grensvoorwaardes en randeffekte 'n groot invloed het op die kalibrasiefaktor van die sensor. Uitgebreide laboratorium toetse is ook gedoen om die sensor topologie sowel as die effekte van die koppelvlak instrumentasie en lekweerstand na grond te evalueer. Uitstekende korrelasie is gevind tussen gemete en voorspelde golfvorms, in beide die tyd- en frekwensie gebied met betrekking tot die kalibrasie faktor sowel as die toegevoegde pole en zeros by lae frekwensies. Die gevolgtrekking is dus dat 'n geldige stroombaanmodel voorgestel is vir die sensor topologieë vir die frekwensie bereik van 10Hz to 1 MHz. Sleutelwoorde: Kapasitiewe sensors, Ope-lug spanningsensors Doctoral 2012-08-27T11:35:22Z 2012-08-27T11:35:22Z 2002-12 Thesis http://hdl.handle.net/10019.1/53222 en_ZA Stellenbosch University 198 p. : ill. application/pdf Stellenbosch : Stellenbosch University
spellingShingle Electric lines
Capacitance meters
Dissertations -- Electrical engineering
Theses -- Electrical engineering
Schilder, Melanie
Wideband modelling of capacitive voltage sensors for open-air transmission line applications
title Wideband modelling of capacitive voltage sensors for open-air transmission line applications
title_full Wideband modelling of capacitive voltage sensors for open-air transmission line applications
title_fullStr Wideband modelling of capacitive voltage sensors for open-air transmission line applications
title_full_unstemmed Wideband modelling of capacitive voltage sensors for open-air transmission line applications
title_short Wideband modelling of capacitive voltage sensors for open-air transmission line applications
title_sort wideband modelling of capacitive voltage sensors for open air transmission line applications
topic Electric lines
Capacitance meters
Dissertations -- Electrical engineering
Theses -- Electrical engineering
url http://hdl.handle.net/10019.1/53222
work_keys_str_mv AT schildermelanie widebandmodellingofcapacitivevoltagesensorsforopenairtransmissionlineapplications