Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Enhancement of cooling tower performance by manipulation of rain zone drop size

Thesis (MEng)--University of Stellenbosch, 1995.

Saved in:
Bibliographic Details
Main Author: Oosthuizen, Henry Randolph
Other Authors: Erens, P. J.
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2012
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613791003344896
access_status_str Open Access
author Oosthuizen, Henry Randolph
author2 Erens, P. J.
author_browse Erens, P. J.
Oosthuizen, Henry Randolph
author_facet Erens, P. J.
Oosthuizen, Henry Randolph
author_sort Oosthuizen, Henry Randolph
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (MEng)--University of Stellenbosch, 1995.
format Thesis
id oai:scholar.sun.ac.za:10019.1/54736
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:41:45.229Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2012
publishDateRange 2012
publishDateSort 2012
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/54736 Enhancement of cooling tower performance by manipulation of rain zone drop size Oosthuizen, Henry Randolph Erens, P. J. Stellenbosch University. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering. Cooling towers -- Computer simulation Drops -- Computer simulation Image processing Dissertations -- Mechanical engineering Theses -- Mechanical engineering Thesis (MEng)--University of Stellenbosch, 1995. AFRIKAANSE OPSOMMING: Die moontlikheid om die warmteoordrag in die reensone van 'n natuurlike trek nat koeltoring te vcrbeter deur die gemiddelde druppel diameter van die sproei te verminder is ondersoek. Eksperimentele wcrk was daarop gerig om tipiese druppelgrootte verspreidings onder druppakking te bepaal, asook die verkryging van werklike verrigtings-data vir verskiJlende pakking en reensone kombinasies in 'n koeltoring toetsfasiliteit. 'n Fotografiese metode wat gebruik maak van beeldverwerkingstegniekc is ontwikkel om die druppelgrootte verspreidings wat in die )meltoring toetsfasiliteit gevind word te bepaal. 'n Rekenaar simulasieprogram wat ontwikkel is deur Dreyer [940Rl] is verder gebruik om reensone verrigtingsdata ( oordragskarakteristieke en druppelgrootte verspreidings) teoreties te vcorspel, vir vergelyking met en evalusie van die eksperimentele resultate. Dit is bewys dat die plasing van 'n laag spatroosters reg onder druppakking die gerniddelde druppeldiameter in die reensone verrninder het, wat gelei het tot 'n ooreenstemmende toename in oordragskarakteristiek. Met die gebruik van 'n rekenaar simulasie program is bereken dat hierdie opstelling die termiese kapasiteit van 'n koeltoring met tot 5 % kan verbeter. ENGLISH ABSTRACT: The possibility of improving the heat transfer in the rain zone of large natural draft wet cooling towers, by decreasing the mean drop diameter in this region, has been investigated. Experimental studies were aimed at determining typical drop size distributions under trickle packs and obtaining actual performance data for packing and rain zone combinations in a cooling tower test facility. A photography-based method, which utilizes image processing techniques, was develo!Jed t() determine the drop size distributions found in the test facility. A computer simulation program developed by Dreyer [94DRI] was used to theoretically predict rain zone performance data (i.e., transfer coefficients and drop size distribution data) for comparison with and evaluation of the experimental data. I: was found that by placing a layer of splash grids beneath a trickle pack the mean drop diameter in the rain zone was decreased, resulting in corresponding increases in transfer characteristic. Using a computer simulation program it was calculated that this arrangement could increase the thermal capacity of a large natural draft cooling tower by up to 5 %. 2012-08-27T11:36:42Z 2012-08-27T11:36:42Z 1995-03 Thesis http://hdl.handle.net/10019.1/54736 en_ZA Stellenbosch University 106 p. ill. application/pdf Stellenbosch : Stellenbosch University
spellingShingle Cooling towers -- Computer simulation
Drops -- Computer simulation
Image processing
Dissertations -- Mechanical engineering
Theses -- Mechanical engineering
Oosthuizen, Henry Randolph
Enhancement of cooling tower performance by manipulation of rain zone drop size
title Enhancement of cooling tower performance by manipulation of rain zone drop size
title_full Enhancement of cooling tower performance by manipulation of rain zone drop size
title_fullStr Enhancement of cooling tower performance by manipulation of rain zone drop size
title_full_unstemmed Enhancement of cooling tower performance by manipulation of rain zone drop size
title_short Enhancement of cooling tower performance by manipulation of rain zone drop size
title_sort enhancement of cooling tower performance by manipulation of rain zone drop size
topic Cooling towers -- Computer simulation
Drops -- Computer simulation
Image processing
Dissertations -- Mechanical engineering
Theses -- Mechanical engineering
url http://hdl.handle.net/10019.1/54736
work_keys_str_mv AT oosthuizenhenryrandolph enhancementofcoolingtowerperformancebymanipulationofrainzonedropsize