Full Text Available
Note: Clicking the button above will open the full text document at the original institutional repository in a new window.
Thesis (MEng)--Stellenbosch University, 1990.
| Main Author: | |
|---|---|
| Other Authors: | |
| Format: | Thesis |
| Language: | af_ZA |
| Published: |
Stellenbosch : Stellenbosch University
2012
|
| Subjects: | |
| Tags: |
No Tags, Be the first to tag this record!
|
| _version_ | 1867613906645549056 |
|---|---|
| access_status_str | Open Access |
| author | Van Aarde, Dirk Jacobus |
| author2 | Kroger, D. G. |
| author_browse | Kroger, D. G. Van Aarde, Dirk Jacobus |
| author_facet | Kroger, D. G. Van Aarde, Dirk Jacobus |
| author_sort | Van Aarde, Dirk Jacobus |
| collection | Thesis |
| dc_rights_str_mv | Stellenbosch University |
| description | Thesis (MEng)--Stellenbosch University, 1990. |
| format | Thesis |
| id | oai:scholar.sun.ac.za:10019.1/69061 |
| institution | Stellenbosch University (South Africa) |
| language | af_ZA |
| last_indexed | 2026-06-10T12:43:35.721Z |
| license_str | Other — see source repository |
| provenance_str_mv | Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository |
| publishDate | 2012 |
| publishDateRange | 2012 |
| publishDateSort | 2012 |
| publisher | Stellenbosch : Stellenbosch University |
| publisherStr | Stellenbosch : Stellenbosch University |
| record_format | dspace |
| source_str | SUNScholar — Stellenbosch University Repository |
| spelling | oai:scholar.sun.ac.za:10019.1/69061 Vloeiverliese deur 'n A-raam vinbuisbundel in 'n lugverkoelde kondensator Van Aarde, Dirk Jacobus Kroger, D. G. Stellenbosch University. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering. Condensers (Steam) -- Cooling Air flow -- Cooling Heat exchangers Fans (Machinery) Thesis (MEng)--Stellenbosch University, 1990. ENGLISH ABSTRACT: The purpose of this thesis is to investigate the flow losses in the vicinity of an A-frame finned tube neat exchanger in a forced craft air cooled condenser. Correlations that describe these flow losses are derived according to experoments performed on a scale model of a finned tube V-bundle. The use of these correlations are illustrated in a sample calculation for a typical full scale forced draft condenser unit. Practical ways to reduce these flow losses are also investigated. Experminets conducted on a full scale condenser unit are discussed and the results compared with those obtained from the scale model. AFRIKAANSE OPSOMMING: Die doel van hierie tesis is om die vloeiverliese in die omgewing van 'n A-raam vinbuisbundel warmteruiler in 'n geforseerde trek lugverkoelde kondensator te ondersoek. Korrelasies wat hierdie vloeiverliese beskryf, word afgelei na aanleiding van eksperimente wat op 'n skaalmodel van 'n vinbuis V-bundel uitgevoer is. Die gebruik van hierdie korrelasies word geïlistreer aan die hand van 'n monsterberekening vir 'n tipiese volskaal geforseerde trek kondensatoreenheid. Daar word ook gekyk na praktiese maniere om hierdie vloeiverliese te verminder. Eksperimente wat uitgevoer is op 'n volskaal kondensatoreenheid word bespreek en die resultate daarvan vergelyk met die resultate verkry vanaf die skaalmodel. Masters 2012-08-27T12:26:54Z 2012-08-27T12:26:54Z 1990 Thesis http://hdl.handle.net/10019.1/69061 af_ZA Stellenbosch University 483 pages : illustrations application/pdf Stellenbosch : Stellenbosch University |
| spellingShingle | Condensers (Steam) -- Cooling Air flow -- Cooling Heat exchangers Fans (Machinery) Van Aarde, Dirk Jacobus Vloeiverliese deur 'n A-raam vinbuisbundel in 'n lugverkoelde kondensator |
| title | Vloeiverliese deur 'n A-raam vinbuisbundel in 'n lugverkoelde kondensator |
| title_full | Vloeiverliese deur 'n A-raam vinbuisbundel in 'n lugverkoelde kondensator |
| title_fullStr | Vloeiverliese deur 'n A-raam vinbuisbundel in 'n lugverkoelde kondensator |
| title_full_unstemmed | Vloeiverliese deur 'n A-raam vinbuisbundel in 'n lugverkoelde kondensator |
| title_short | Vloeiverliese deur 'n A-raam vinbuisbundel in 'n lugverkoelde kondensator |
| title_sort | vloeiverliese deur n a raam vinbuisbundel in n lugverkoelde kondensator |
| topic | Condensers (Steam) -- Cooling Air flow -- Cooling Heat exchangers Fans (Machinery) |
| url | http://hdl.handle.net/10019.1/69061 |
| work_keys_str_mv | AT vanaardedirkjacobus vloeiverliesedeurnaraamvinbuisbundelinnlugverkoeldekondensator |