Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Evaluation and performance enhancement of cooling tower spray zones

Thesis (MScEng)--Stellenbosch University, 2012.

Saved in:
Bibliographic Details
Main Author: Roux, Daniel
Other Authors: Reuter, H. C. R.
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2012
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613763040968706
access_status_str Open Access
author Roux, Daniel
author2 Reuter, H. C. R.
author_browse Reuter, H. C. R.
Roux, Daniel
author_facet Reuter, H. C. R.
Roux, Daniel
author_sort Roux, Daniel
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (MScEng)--Stellenbosch University, 2012.
format Thesis
id oai:scholar.sun.ac.za:10019.1/71944
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:41:18.607Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2012
publishDateRange 2012
publishDateSort 2012
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/71944 Evaluation and performance enhancement of cooling tower spray zones Roux, Daniel Reuter, H. C. R. Stellenbosch University. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering. Water distribution Spray patterns Cooling towers Spray nozzles Mechanical & Mechatronic Engineering Thesis (MScEng)--Stellenbosch University, 2012. ENGLISH ABSTRACT: The performance of wet cooling towers can be improved by installing spray nozzles that distribute the cooling water uniformly onto the fill whilst operating at a low pressure head. In this thesis, three commercial spray nozzles are experimentally evaluated in terms of flow and pressure loss characteristics as well as water distribution patterns. The results of the evaluation process highlight the need for spray nozzles with enhanced performance characteristics. The theory required to implement the results of the evaluation process in the design of a cooling tower is presented and discussed. A systematic approach to enhance the performance of a spray nozzle through minor alterations is applied to one of the commercial spray nozzles that was evaluated. The fluid dynamics of an orifice nozzle, such as the effect of a change in pressure head, spray angle, spray height, orifice diameter and wall thickness on drop diameter and spray distance, is experimentally investigated and a model with which a spray nozzle can be designed is finally presented. Two prototype spray nozzles show that it is possible to enhance the performance of spray nozzles and thus wet cooling towers by means of the methods presented. AFRIKAANSE OPSOMMING: Die werkverrigting van natkoeltorings kan verbeter word deur sproeiers te installeer wat die verkoelingswater uniform versprei op die pakking teen 'n lae pomp drukhoogte. In hierdie tesis word drie kommersiële sproeiers eksperimenteel geëvalueer in terme van vloei en drukverlies eienskappe sowel as water verdelings patrone. Die resultate van die evaluasie proses beklemtoon die behoefte aan sproeiers met verbeterde werkverrigtingseienskappe. Die teorie wat benodig word om die resultate van die evaluasie proses te implementeer in die ontwerp van 'n natkoeltoring word bespreek. 'n Stelselmatige benadering om die werkverrigtings van 'n sproeier te verhoog deur klein veranderinge aan die ontwerp aan te bring, word toegepas op een van die sproeiers wat getoets is. Die vloeidinamika van 'n plaatmondstuk, soos die effek van 'n verandering in drukhoogte, sproeihoek, sproeihoogte, gatdiameter en wanddikte op druppel diameter en sproeiafstand, is eksperimenteel ondersoek en 'n model word aangebied waarmee 'n sproeier ontwerp kan word. Twee prototipe sproeiers wys dat dit moontlik is om die werkverrigting van sproeiers, en dus ook natkoeltorings, te verbeter deur die metodes wat in die tesis aangebied word, toe te pas. 2012-11-28T06:03:20Z 2012-12-12T08:17:12Z 2013-06-30T22:10:04Z 2012-12 Thesis http://hdl.handle.net/10019.1/71944 en_ZA Stellenbosch University application/pdf application/pdf Stellenbosch : Stellenbosch University
spellingShingle Water distribution
Spray patterns
Cooling towers
Spray nozzles
Mechanical & Mechatronic Engineering
Roux, Daniel
Evaluation and performance enhancement of cooling tower spray zones
title Evaluation and performance enhancement of cooling tower spray zones
title_full Evaluation and performance enhancement of cooling tower spray zones
title_fullStr Evaluation and performance enhancement of cooling tower spray zones
title_full_unstemmed Evaluation and performance enhancement of cooling tower spray zones
title_short Evaluation and performance enhancement of cooling tower spray zones
title_sort evaluation and performance enhancement of cooling tower spray zones
topic Water distribution
Spray patterns
Cooling towers
Spray nozzles
Mechanical & Mechatronic Engineering
url http://hdl.handle.net/10019.1/71944
work_keys_str_mv AT rouxdaniel evaluationandperformanceenhancementofcoolingtowersprayzones