Hydration sensor development for use on infants in underserved areas

Thesis (MEng)--Stellenbosch University, 2015.

Saved in:
Bibliographic Details
Main Author: Kieser, Eduard
Other Authors: Van den Heever, David Jacobus
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2015
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867614130374967296
access_status_str Open Access
author Kieser, Eduard
author2 Van den Heever, David Jacobus
author_browse Kieser, Eduard
Van den Heever, David Jacobus
author_facet Van den Heever, David Jacobus
Kieser, Eduard
author_sort Kieser, Eduard
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (MEng)--Stellenbosch University, 2015.
format Thesis
id oai:scholar.sun.ac.za:10019.1/98029
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:47:08.513Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2015
publishDateRange 2015
publishDateSort 2015
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/98029 Hydration sensor development for use on infants in underserved areas Kieser, Eduard Van den Heever, David Jacobus Dellimore, Kiran Stellenbosch University. Faculty of Engineering. Dept. of Mechanical and Mechatronic Engineering. Infants -- Dehydration Clinical hydration scales Dehydration -- Assessment Hydration sensor development UCTD Thesis (MEng)--Stellenbosch University, 2015. ENGLISH ABSTRACT: To treat dehydration in infants a good measure of dehydration level is required. Clinical hydration scales are the standard for assessing hydration upon first examination. These scales rely on the training of the physician and do not perform well when applied in underserved settings where the vast majority of infant mortalities due to dehydration occur. This study proposes three sensors for the non-invasive assessment of dehydration. All three sensors measure proven indicators of hydration (capillary refill time, skin recoil time and skin temperature difference) and the aim is to eventually allow untrained personnel to reliably measure these hydration markers with greater inter-rater reliability. A proof of concept prototype of each sensor was fabricated and the sensors were tested in two separate studies. The skin recoil time and temperature profile sensors seemed to perform fairly well when tested on infants, however, because of the small sample size of the infant study, no real conclusions could be drawn about the link between the measured markers and hydration state. A systematic method of finding a model, that combines the best predictors, was presented, however the model performed only marginally better than the best individual marker, most likely due to wanting orthogonality between the predictors. Skin recoil time, which is the marker that performed best in the clinical study, achieved a sensitivity and specificity of 0.8 and 0.84 respectively for detecting 5% dehydration, which is better than the expected performance of any single commonly accepted hydration marker. Interestingly, this combination of sensitivity and specificity was achieved at a binary threshold of 0.08 seconds. As mentioned previously, the data does not make it possible to draw solid conclusions about the performance of the device, however the presented evidence makes a strong case for continued research into the presented methods. AFRIKAANSE OPSOMMING: Dit is belangrik om dehidrasie in kleinkinders akkuraat te meet om sodoende die regte behandeling toe te pas. Kliniese hidrasie skale is die standaard vir die bepaling van hidrasie met die eerste ondersoek. Hierdie skale vertrou op die opleiding en ondervinding van die dokter en is nie baie betroubaar wanneer dit gebruik word in onbediende areas waar die oorgrootte meerderheid van kindersterftes weens dehidrasie is. Hierdie navorsing stel drie sensors voor vir nie-indringende assessering van dehidrasie. Al drie sensors meet bewese indikators van dehidrasie (kapillêre hervultyd, vel-terugkrimping en veltemperatuur-verskil) en die doel is om uiteindelik onopgeleide personeel toe te laat om hierdie merkers betroubaar te meet. ‘n Bewys-van-konsep prototipe van elke van die sensors is vervaardig en getoets in twee verksillende studies. Die vel-terugkrimping en veltemperatuur-verskil sensors het heel goed gevaar toe dit op die kleinkinders getoets is, maar vanweë die klein toetsgroep kon geen ware afleidings gemaak word tussen die verwantskap van die gemete merkers en die hidrasietoestand nie. ‘n Sistematiese metode om ‘n model te vind wat die beste voorspellers kombineer is voorgestel, maar die model het egter slegs marginaal beter presteer as die beste individuele merker, heel moontlik vanweë ‘n tekort aan ortogonaliteit tussen die voorspellers. Vel-terugkrimping, die merker wat die beste presteer het in die kliniese studie, het onderskeidelik ‘n sensitiwiteit en spesifiekheid van 0.8 en 0.84 behaal vir die opsporing van 5% dehidrasie, wat beter is as die verwagte verrigting van enige van die ander algemeen aanvaarde hidrasiemerkers. Interessant genoeg is die kombinasie van sensitiwiteit en spesifiekheid behaal by ‘n binêre grens van 0.08 sekondes. Soos voorheen genoem is dit met die data nie moontlik om konkrete gevolgtrekkings te maak rakende die gedrag van die toestel nie, maar die voorgestelde bewyse maak ‘n sterk saak vir verdere navorsing oor die voorgestelde metodes. 2015-12-14T07:43:54Z 2015-12-14T07:43:54Z 2015-12 Thesis http://hdl.handle.net/10019.1/98029 en_ZA Stellenbosch University 122 pages : illustrations application/pdf Stellenbosch : Stellenbosch University
spellingShingle Infants -- Dehydration
Clinical hydration scales
Dehydration -- Assessment
Hydration sensor development
UCTD
Kieser, Eduard
Hydration sensor development for use on infants in underserved areas
title Hydration sensor development for use on infants in underserved areas
title_full Hydration sensor development for use on infants in underserved areas
title_fullStr Hydration sensor development for use on infants in underserved areas
title_full_unstemmed Hydration sensor development for use on infants in underserved areas
title_short Hydration sensor development for use on infants in underserved areas
title_sort hydration sensor development for use on infants in underserved areas
topic Infants -- Dehydration
Clinical hydration scales
Dehydration -- Assessment
Hydration sensor development
UCTD
url http://hdl.handle.net/10019.1/98029
work_keys_str_mv AT kiesereduard hydrationsensordevelopmentforuseoninfantsinunderservedareas