Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy

Summary in English.

Saved in:
Bibliographic Details
Main Author: Hough, Jan K
Other Authors: Vaughan, Christopher Leonard (Kit)
Format: Thesis
Language:English
Published: Division of Medical Physics 2018
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613146312605696
access_status_str Open Access
author Hough, Jan K
author2 Vaughan, Christopher Leonard (Kit)
author_browse Hough, Jan K
Vaughan, Christopher Leonard (Kit)
author_facet Vaughan, Christopher Leonard (Kit)
Hough, Jan K
author_sort Hough, Jan K
collection Thesis
description Summary in English.
format Thesis
id oai:open.uct.ac.za:11427/26784
institution University of Cape Town (South Africa)
language eng
last_indexed 2026-06-10T12:31:30.019Z
license_str Not specified — see source repository
provenance_str_mv Harvested via OAI-PMH from UCTD — University of Cape Town Open Access Repository
publishDate 2018
publishDateRange 2018
publishDateSort 2018
publisher Division of Medical Physics
publisherStr Division of Medical Physics
record_format dspace
source_str UCTD — University of Cape Town Open Access Repository
spelling oai:open.uct.ac.za:11427/26784 Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy Hough, Jan K Vaughan, Christopher Leonard (Kit) Medical Physics Summary in English. Bibliography: pages 125-129. This thesis describes the construction and use of the facemask at the National Accelerator Centre (NAC) as used to both immobilise and position patients for precision proton radiotherapy. The precision achieved using the stereophotogrammetric (SPG) positioning system is measured, and the shortcomings and errors in using the facemask by the SPG system are measured and analysed. The implementation of improvements made to the SPG system is reported upon, and alternative means of both supporting the fiducial markers and immobilising the patient are investigated and evaluated. The accuracy of positioning a facemask using the SPG system is 1.4 mm and of positioning a newly designed frame is 1.6 mm. These measurements were made without using a patient. It is estimated that the total uncertainty of positioning a patient's tumour at the isocentre is 1.6 (1SD) mm using the facemask and it is estimated that the precision using the frame will be less than this value. The largest component of this error (1.39 mm) is due to the error in obtaining the CT scanner co-ordinates. These results are comparable to those obtained by other investigators. The movement of patient bony landmarks within the facemask was measured to be 1.0 ± 0.8 mm. Three main recommendations are that the CT scanner co-ordinating procedure be improved, the SPG computer program be rewritten in parts to achieve greater speed and accuracy, and that the new frame be used. The frame is easier to manufacture than the facemask and allows real time monitoring of the position of the patient's head by the SPG system thus allowing faster throughput of patients and better positioning quality control. 2018-01-09T14:11:43Z 2018-01-09T14:11:43Z 1999 Master Thesis Masters MPhil http://hdl.handle.net/11427/26784 eng application/pdf Division of Medical Physics Faculty of Health Sciences University of Cape Town
spellingShingle Medical Physics
Hough, Jan K
Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy
thesis_degree_str Master's
title Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy
title_full Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy
title_fullStr Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy
title_full_unstemmed Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy
title_short Assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy
title_sort assessment of and improvements to a stereophotogrammetric patient positioning system for proton therapy
topic Medical Physics
url http://hdl.handle.net/11427/26784
work_keys_str_mv AT houghjank assessmentofandimprovementstoastereophotogrammetricpatientpositioningsystemforprotontherapy