Full Text Available

Note: Clicking the button above will open the full text document at the original institutional repository in a new window.

Loaded transmission lines illuminated above ground

Thesis (M.Sc.Ing) -- University of Stellenbosch, 1999.

Saved in:
Bibliographic Details
Main Author: Stuart, Thomas
Other Authors: Reader, H. C.
Format: Thesis
Language:en_ZA
Published: Stellenbosch : Stellenbosch University 2012
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1867613896003551232
access_status_str Open Access
author Stuart, Thomas
author2 Reader, H. C.
author_browse Reader, H. C.
Stuart, Thomas
author_facet Reader, H. C.
Stuart, Thomas
author_sort Stuart, Thomas
collection Thesis
dc_rights_str_mv Stellenbosch University
description Thesis (M.Sc.Ing) -- University of Stellenbosch, 1999.
format Thesis
id oai:scholar.sun.ac.za:10019.1/51324
institution Stellenbosch University (South Africa)
language en_ZA
last_indexed 2026-06-10T12:43:25.190Z
license_str Other — see source repository
provenance_str_mv Harvested via OAI-PMH from SUNScholar — Stellenbosch University Repository
publishDate 2012
publishDateRange 2012
publishDateSort 2012
publisher Stellenbosch : Stellenbosch University
publisherStr Stellenbosch : Stellenbosch University
record_format dspace
source_str SUNScholar — Stellenbosch University Repository
spelling oai:scholar.sun.ac.za:10019.1/51324 Loaded transmission lines illuminated above ground Stuart, Thomas Reader, H. C. Stellenbosch University. Faculty of Engineering. Dept. of Electrical & Electronic Engineering. Electromagnetic compatibility Electric interference Dissertations -- Electronic engineering Thesis (M.Sc.Ing) -- University of Stellenbosch, 1999. ENGLISH ABSTRACT: This thesis provides a solution to an EMC problem that arose from an open cast mining system, which suffered from premature detonation. The industry problem is treated as a generic wiring problem, where a transmission line above a ground is illuminated by a plane wave noise source. By choosing appropriate transmission line termination loads, a minimum in the noise power at one termination is sought. Systematic variation of the loads is carried out above both and ideal and a lossy ground. Simulations are performed using NEC4D, which is a well established wire-based method-of-moments frequency-domain code, and MTL_SIM, which is a one-dimensional finite-difference time-domain code. A careful measurement above each type of ground is performed to confirm the accuracy of the measurements. In order to perform a measurement above lossy ground an artificial dielectric with electrical characteristics similar to soil is used. The electrical characteristics of the artificial soil are measured using a stripline system that was developed for that purpose. It was found that by choosing suitable loads the noise power can be considerably reduced. This is a low cost solution to the problem, and is easy to accomplish. At the same time the ability to measure and simulate this type of problem is developed. AFRIKAANSE OPSOMMING: Hierdie tesis bied 'n oplossing vir 'n EMV probleem wat by 'n oopgroef myn ontstaan het. Ongewenste detonasies is veroorsaak deur onverwagte platvlakgolf straling. Hierdie probleem word as 'n bedraadingsisteem, waar 'n belaste transmissielyn onder die invloed van platvlakgolfstraling verkeer, behandel. Die transmissielyn terminasies word sistematies bokant beide ideale en nie-ideale grondvlakke gevarieer, en die ruisdrywing in die terminasies gemeet. Simulasies is met NEC4D, 'n Momentmetode frekwesiegebiedkode, en MTL_SIM, 'n eendimensionele eindige element tydgebiedkode, uitgevoer. Die akuraatheid van die simulasies word getoets teen resultate van 'n sorgvuldige meetproses. As nie-ideale grondvlak is 'n dielektriese medium met elektriese eienskappe soortgelyk aan die van ware grond gebruik. 'n Strooklyn meetopstelling is ontwerp om die elektriese eienskappe van die dielektrikum te meet. Resultate van simulasies en metings to on duidelik dat die korrekte keuse van transmissielyn terminasies is minimum ruisdrywing in die terminasies tot gevolg kan he. Sodoende word 'n laekoste oplossing vir die spesifieke probleem daargestel terwyl insig in die oplossing van die soort EMV -probleme in die algemeen verkry word. Master 2012-08-27T11:34:26Z 2012-08-27T11:34:26Z 1999-12 Thesis http://hdl.handle.net/10019.1/51324 en_ZA Stellenbosch University 1 v. (various pagings) : ill. application/pdf Stellenbosch : Stellenbosch University
spellingShingle Electromagnetic compatibility
Electric interference
Dissertations -- Electronic engineering
Stuart, Thomas
Loaded transmission lines illuminated above ground
title Loaded transmission lines illuminated above ground
title_full Loaded transmission lines illuminated above ground
title_fullStr Loaded transmission lines illuminated above ground
title_full_unstemmed Loaded transmission lines illuminated above ground
title_short Loaded transmission lines illuminated above ground
title_sort loaded transmission lines illuminated above ground
topic Electromagnetic compatibility
Electric interference
Dissertations -- Electronic engineering
url http://hdl.handle.net/10019.1/51324
work_keys_str_mv AT stuartthomas loadedtransmissionlinesilluminatedaboveground